Impact of diastolic dysfunction severity on global left ventricular volumetric filling - assessment by automated segmentation of routine cine cardiovascular magnetic resonance

被引:47
|
作者
Mendoza, Dorinna D. [1 ]
Codella, Noel C. F. [2 ]
Wang, Yi [2 ]
Prince, Martin R. [2 ]
Sethi, Sonia [1 ]
Manoushagian, Shant J. [1 ]
Kawaji, Keigo [2 ]
Min, James K. [1 ,2 ]
LaBounty, Troy M. [1 ]
Devereux, Richard B. [1 ]
Weinsaft, Jonathan W. [1 ,2 ]
机构
[1] Weill Cornell Med Coll, Div Cardiol, Dept Med, New York, NY USA
[2] Weill Cornell Med Coll, Dept Radiol, New York, NY USA
关键词
CORONARY-ARTERY-DISEASE; MYOCARDIAL-INFARCTION; DOPPLER-ECHOCARDIOGRAPHY; CHAMBER QUANTIFICATION; PROGNOSTIC IMPORTANCE; HEART-FAILURE; RECOMMENDATIONS; PATTERNS;
D O I
10.1186/1532-429X-12-46
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To examine relationships between severity of echocardiography (echo) -evidenced diastolic dysfunction (DD) and volumetric filling by automated processing of routine cine cardiovascular magnetic resonance (CMR). Background: Cine-CMR provides high-resolution assessment of left ventricular (LV) chamber volumes. Automated segmentation (LV-METRIC) yields LV filling curves by segmenting all short-axis images across all temporal phases. This study used cine-CMR to assess filling changes that occur with progressive DD. Methods: 115 post-MI patients underwent CMR and echo within 1 day. LV-METRIC yielded multiple diastolic indices E:A ratio, peak filling rate (PFR), time to peak filling rate (TPFR), and diastolic volume recovery (DVR80 - proportion of diastole required to recover 80% stroke volume). Echo was the reference for DD. Results: LV-METRIC successfully generated LV filling curves in all patients. CMR indices were reproducible (<= 1% inter-reader differences) and required minimal processing time (175 +/- 34 images/exam, 2:09 +/- 0:51 minutes). CMR E:A ratio decreased with grade 1 and increased with grades 2-3 DD. Diastolic filling intervals, measured by DVR80 or TPFR, prolonged with grade 1 and shortened with grade 3 DD, paralleling echo deceleration time (p < 0.001). PFR by CMR increased with DD grade, similar to E/e' (p < 0.001). Prolonged DVR80 identified 71% of patients with echoevidenced grade 1 but no patients with grade 3 DD, and stroke-volume adjusted PFR identified 67% with grade 3 but none with grade 1 DD (matched specificity = 83%). The combination of DVR80 and PFR identified 53% of patients with grade 2 DD. Prolonged DVR80 was associated with grade 1 (OR 2.79, CI 1.65-4.05, p = 0.001) with a similar trend for grade 2 (OR 1.35, CI 0.98-1.74, p = 0.06), whereas high PFR was associated with grade 3 (OR 1.14, CI 1.02-1.25, p = 0.02) DD. Conclusions: Automated cine-CMR segmentation can discern LV filling changes that occur with increasing severity of echo-evidenced DD. Impaired relaxation is associated with prolonged filling intervals whereas restrictive filling is characterized by increased filling rates.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [1] Impact of diastolic dysfunction severity on global left ventricular volumetric filling - assessment by automated segmentation of routine cine cardiovascular magnetic resonance
    Dorinna D Mendoza
    Noel CF Codella
    Yi Wang
    Martin R Prince
    Sonia Sethi
    Shant J Manoushagian
    Keigo Kawaji
    James K Min
    Troy M LaBounty
    Richard B Devereux
    Jonathan W Weinsaft
    Journal of Cardiovascular Magnetic Resonance, 12
  • [2] Automated segmentation of routine cine-CMR for volumetric assessment of presence and severity of left ventricular diastolic dysfunction
    Dorinna D Mendoza
    Noel CF Codella
    Sonia Sethi
    Keigo Kawaji
    Shant Manoushagian
    Martin R Prince
    Richard B Devereux
    James K Min
    Matthew D Cham
    Yi Wang
    Jonathan W Weinsaft
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [3] Automated Segmentation of Routine Clinical Cardiac Magnetic Resonance Imaging for Assessment of Left Ventricular Diastolic Dysfunction
    Kawaji, Keigo
    Codella, Noel C. F.
    Prince, Martin R.
    Chu, Christopher W.
    Shakoor, Aqsa
    LaBounty, Troy M.
    Min, James K.
    Swaminathan, Rajesh V.
    Devereux, Richard B.
    Wang, Yi
    Weinsaft, Jonathan W.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2009, 2 (06) : 476 - 484
  • [4] Routine evaluation of left ventricular diastolic function by cardiovascular magnetic resonance: A practical approach
    Rathi, Vikas K.
    Doyle, Mark
    Yamrozik, June
    Williams, Ronald B.
    Caruppannan, Ketheswaram
    Truman, Craig
    Vido, Diane
    Biederman, Robert W. W.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2008, 10 (1)
  • [5] Routine evaluation of left ventricular diastolic function by cardiovascular magnetic resonance: A practical approach
    Vikas K Rathi
    Mark Doyle
    June Yamrozik
    Ronald B Williams
    Ketheswaram Caruppannan
    Craig Truman
    Diane Vido
    Robert WW Biederman
    Journal of Cardiovascular Magnetic Resonance, 10
  • [6] Rapid, routine evaluation of left ventricular diastolic function and left ventricular filling pressures during cardiac magnetic resonance imaging
    Padmini Varadarajan
    Raas Pai
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [7] Cardiovascular magnetic resonance for the assessment of left ventricular filling pressure in heart failure
    Baritussio, Anna
    Muthurangu, Vivek
    EUROPEAN HEART JOURNAL, 2022, 43 (26) : 2523 - 2525
  • [8] The importance of late left ventricular diastolic filling wave propagation in assessment of diastolic dysfunction
    Patrianakos, AP
    Parthenakis, FI
    Diakakis, GF
    Chrysostomakis, SI
    Tsoutsoumanou, C
    Vardas, PE
    EUROPEAN HEART JOURNAL, 2002, 23 : 33 - 33
  • [9] Cardiovascular magnetic resonance can improve the precision for left ventricular filling pressure assessment
    Gosling, Rebecca
    Swift, Andrew J.
    Garg, Pankaj
    EUROPEAN HEART JOURNAL, 2023, 44 (05) : 427 - 428
  • [10] A NEW METHOD FOR ASSESSMENT OF LEFT VENTRICULAR FILLING PRESSURE USING CARDIOVASCULAR MAGNETIC RESONANCE
    Alhogbani, T.
    Strohm, O.
    Friedrich, M.
    CANADIAN JOURNAL OF CARDIOLOGY, 2010, 26 : 126D - 126D