Routine evaluation of left ventricular diastolic function by cardiovascular magnetic resonance: A practical approach

被引:104
|
作者
Rathi, Vikas K. [1 ]
Doyle, Mark [1 ]
Yamrozik, June [1 ]
Williams, Ronald B. [1 ]
Caruppannan, Ketheswaram [1 ]
Truman, Craig [1 ]
Vido, Diane [1 ]
Biederman, Robert W. W. [1 ]
机构
[1] Drexel Univ, Allegheny Gen Hosp, Div Cardiol, Coll Med, Pittsburgh, PA 15212 USA
关键词
D O I
10.1186/1532-429X-10-36
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Cardiovascular magnetic resonance (CMR) has excellent capabilities to assess ventricular systolic function. Current clinical scenarios warrant routine evaluation of ventricular diastolic function for complete evaluation, especially in congestive heart failure patients. To our knowledge, no systematic assessment of diastolic function over a range of lusitropy has been performed using CMR. Methods and Results: Left ventricular diastolic function was assessed in 31 subjects (10 controls) who underwent CMR and compared with Transthoracic echocardiogram (TTE) evaluation of mitral valve (MV) and pulmonary vein (PV) blood flow. Blood flow in the MV and PV were successfully imaged by CMR for all cases (31/31,100%) while TTE evaluated flow in all MV (31/31,100%) but only 21/31 PV (68%) cases. Velocities of MV flow (E and A) measured by CMR correlated well with TTE (r = 0.81, p < 0.001), but demonstrated a systematic underestimation by CMR compared to TTE (slope = 0.77). Bland-Altman analysis of the E: A ratio and deceleration time (DT) calculated from each modality showed excellent agreement (bias -0.29, and -10.3 ms for E: A and DT, respectively). When assessing morphology using TTE, CMR correctly identified patients as having normal or abnormal inflow conditions. Conclusion: We have shown that there is homology between CMR and TTE for the assessment of diastolic inflow over a wide range of conditions, including normal, impaired relaxation and restrictive. There is excellent agreement of quantitative velocity measurements between CMR and TTE. Diastolic blood flow assessment by CMR can be performed in a single scan, with times ranging from 20 sec to 3 min, and we show that there is good indication for applying CMR to assess diastolic conditions, either as an adjunctive test when evaluating systolic function, or even as a primary test when TTE data cannot be obtained.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Routine evaluation of left ventricular diastolic function by cardiovascular magnetic resonance: A practical approach
    Vikas K Rathi
    Mark Doyle
    June Yamrozik
    Ronald B Williams
    Ketheswaram Caruppannan
    Craig Truman
    Diane Vido
    Robert WW Biederman
    Journal of Cardiovascular Magnetic Resonance, 10
  • [2] Rapid, routine evaluation of left ventricular diastolic function and left ventricular filling pressures during cardiac magnetic resonance imaging
    Padmini Varadarajan
    Raas Pai
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [3] Cardiovascular magnetic resonance evaluation for left ventricular diastolic function: analysis of time-volume curve
    Takashi Tanimoto
    Keizo Kimura
    Shingo Ota
    Tomizo Masuno
    Yuichi Ozaki
    Kumiko Hirata
    Takashi Kubo
    Imanishi Toshio
    Takashi Akasaka
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [4] Evaluation of left ventricular diastolic function by fractional area change using cine cardiovascular magnetic resonance: a feasibility study
    Okayama, Satoshi
    Nakano, Tomoya
    Uemura, Shiro
    Fujimoto, Shinichi
    Somekawa, Satoshi
    Watanabe, Makoto
    Nakajima, Tamio
    Saito, Yoshihiko
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
  • [5] Evaluation of left ventricular diastolic function by fractional area change using cine cardiovascular magnetic resonance: a feasibility study
    Satoshi Okayama
    Tomoya Nakano
    Shiro Uemura
    Shinichi Fujimoto
    Satoshi Somekawa
    Makoto Watanabe
    Tamio Nakajima
    Yoshihiko Saito
    Journal of Cardiovascular Magnetic Resonance, 15
  • [6] Evaluation of left ventricular diastolic function in patients with coronary microvascular dysfunction via cardiovascular magnetic resonance feature tracking
    Kong, Huihui
    Cao, Jiaxin
    Tian, Jinfan
    Yong, Jingwen
    An, Jing
    Zhang, Lijun
    Song, Xiantao
    He, Yi
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (10) : 7281 - 7293
  • [7] Evaluation of left ventricular torsion by cardiovascular magnetic resonance
    Alistair A Young
    Brett R Cowan
    Journal of Cardiovascular Magnetic Resonance, 14
  • [8] Evaluation of left ventricular torsion by cardiovascular magnetic resonance
    Young, Alistair A.
    Cowan, Brett R.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2012, 14
  • [9] Automated left ventricular diastolic function evaluation from phase-contrast cardiovascular magnetic resonance and comparison with Doppler echocardiography
    Bollache, Emilie
    Redheuil, Alban
    Clement-Guinaudeau, Stephanie
    Defrance, Carine
    Perdrix, Ludivine
    Ladouceur, Magalie
    Lefort, Muriel
    De Cesare, Alain
    Herment, Alain
    Diebold, Benoit
    Mousseaux, Elie
    Kachenoura, Nadjia
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2010, 12
  • [10] Evaluation of left ventricular systolic and diastolic function in subjects with prediabetes and diabetes using cardiovascular magnetic resonance-feature tracking
    Shanshan Zhou
    Zheng Zhang
    Zhen Zhang
    Yiyuan Gao
    Gengxiao Li
    Mingwu Lou
    Zhiwei Zhao
    Jun Zhao
    Kuncheng Li
    Gerald M. Pohost
    Acta Diabetologica, 2022, 59 : 491 - 499