Artifact analysis of approximate helical cone-beam CT reconstruction algorithms

被引:34
|
作者
Köhler, T
Proksa, R
Bontus, C
Grass, M
Timmer, J
机构
[1] Philips Res Labs, Sector Tech Syst, D-22335 Hamburg, Germany
[2] Philips Med Syst, NL-5680 DA Best, Netherlands
关键词
cone-beam CT; cone-beam reconstruction; helical CT; PI; PI-SLANT; n-PI; ASSR;
D O I
10.1118/1.1413518
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this paper, four approximate cone-beam CT reconstruction algorithms are compared: Advanced single slice rebinning (ASSR) as a representative of algorithms employing a two dimensional approximation, PI, PI-SLANT, and 3-PI which all use a proper three dimensional back-projection. A detailed analysis of the image artifacts produced by these techniques shows that aliasing in the z-direction is the predominant source of artifacts for a 16-row scanner with 1.25 mm nominal slice thickness. For a detector with isotropic resolution of 0.5 mm, we found that ASSR and PI produce different kinds of artifacts which are almost at the same level, while PI-SLANT produces none of these artifacts. It is shown that the used of redundant data in the 3-PI method suppresses aliasing artifacts efficiently for both scanners. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:51 / 64
页数:14
相关论文
共 50 条
  • [41] Redundant data and exact helical cone-beam reconstruction
    Heuscher, D
    Brown, K
    Noo, F
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11): : 2219 - 2238
  • [42] The frequency split method for helical cone-beam reconstruction
    Shechter, G
    Köhler, T
    Altman, A
    Proksa, R
    [J]. MEDICAL PHYSICS, 2004, 31 (08) : 2230 - 2236
  • [43] A family of analytic algorithms for cone-beam CT
    Zhao, SY
    Yu, HY
    Wang, G
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 318 - 328
  • [44] Comparison of cone-beam (CB) reconstruction algorithms in spiral computed tomography (CT)
    Sourbelle, K
    Lauritsch, G
    Tam, KC
    Kachelriess, M
    Kalender, WA
    [J]. RADIOLOGY, 2002, 225 : 253 - 253
  • [45] A new approximate algorithm for image reconstruction in cone-beam spiral CT at small cone-angles
    Schaller, S
    Flohr, T
    Steffen, P
    [J]. 1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1703 - 1709
  • [46] A motion-compensated scheme for helical cone-beam reconstruction in cardiac CT angiography
    van Stevendaal, U.
    von Berg, J.
    Lorenz, C.
    Grass, M.
    [J]. MEDICAL PHYSICS, 2008, 35 (07) : 3239 - 3251
  • [47] Application of dual-energy techniques to helical, cone-beam CT image reconstruction
    Sidky, E
    Zou, Y
    Pan, X
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1408 - 1408
  • [48] A rebinned backprojection-filtration algorithm for image reconstruction in helical cone-beam CT
    Yu, Lifeng
    Xia, Dan
    Zou, Yu
    Sidky, Emil Y.
    Bian, Junguo
    Pan, Xiaochuan
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (18): : 5497 - 5508
  • [49] Helical CT reconstruction from wide cone-beam angle data using ART
    Carvalho, BM
    Herman, GT
    [J]. XVI BRAZILIAN SYMPOSIUM ON COMPUTER GRAPHICS AND IMAGE PROCESSING, PROCEEDINGS, 2003, : 363 - 370
  • [50] Exact reconstruction for unequally spaced triple-source helical cone-beam CT
    Jin, Yannan
    Zhao, Jun
    Jiang, Ming
    Zhuang, Tiange
    Wang, Ge
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318