Artifact analysis of approximate helical cone-beam CT reconstruction algorithms

被引:34
|
作者
Köhler, T
Proksa, R
Bontus, C
Grass, M
Timmer, J
机构
[1] Philips Res Labs, Sector Tech Syst, D-22335 Hamburg, Germany
[2] Philips Med Syst, NL-5680 DA Best, Netherlands
关键词
cone-beam CT; cone-beam reconstruction; helical CT; PI; PI-SLANT; n-PI; ASSR;
D O I
10.1118/1.1413518
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this paper, four approximate cone-beam CT reconstruction algorithms are compared: Advanced single slice rebinning (ASSR) as a representative of algorithms employing a two dimensional approximation, PI, PI-SLANT, and 3-PI which all use a proper three dimensional back-projection. A detailed analysis of the image artifacts produced by these techniques shows that aliasing in the z-direction is the predominant source of artifacts for a 16-row scanner with 1.25 mm nominal slice thickness. For a detector with isotropic resolution of 0.5 mm, we found that ASSR and PI produce different kinds of artifacts which are almost at the same level, while PI-SLANT produces none of these artifacts. It is shown that the used of redundant data in the 3-PI method suppresses aliasing artifacts efficiently for both scanners. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:51 / 64
页数:14
相关论文
共 50 条
  • [11] Practical helical cone-beam algorithms for multislice volumetric CT
    Patch, SK
    Besson, GM
    [J]. RADIOLOGY, 1999, 213P : 451 - 451
  • [12] Reconstruction from minimum data in helical cone-beam CT
    Zou, Y
    Pan, XC
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3235 - 3238
  • [13] Accurate helical cone-beam CT reconstruction with redundant data
    Schoendube, Harald
    Stierstorfer, Karl
    Noo, Frederic
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (15): : 4625 - 4644
  • [14] Accurate computation of the Hotelling observer for the evaluation of image reconstruction algorithms in helical, cone-beam CT
    Sidky, Emil Y.
    LaRoque, Samuel J.
    Pan, Xiaochuan
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3233 - 3236
  • [15] Benchmarking of different reconstruction algorithms for industrial cone-beam CT
    Rathore, Jitendra Singh
    Laquai, René
    Biguri, Ander
    Soleimani, Manuchehr
    Vienne, Caroline
    [J]. e-Journal of Nondestructive Testing, 2022, 27 (03):
  • [16] BPF-Type Reconstruction for Dual Helical Cone-Beam CT
    Zeng, Li
    Zou, Xiaobing
    [J]. CURRENT MEDICAL IMAGING, 2011, 7 (02) : 125 - 135
  • [17] Exact reconstruction of volumetric images in reverse helical cone-beam CT
    Cho, Seungryong
    Xia, Dan
    Pelizzari, Charles A.
    Pan, Xiaochuan
    [J]. MEDICAL PHYSICS, 2008, 35 (07) : 3030 - 3040
  • [18] Tilted helical Feldkamp cone-beam reconstruction algorithm for multislice CT
    Hein, IA
    Taguchi, K
    Mori, I
    Kazama, M
    Silver, MD
    [J]. MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1901 - 1910
  • [19] Exact image reconstruction for selected ROI in helical cone-beam CT
    Pan, XC
    Zou, Y
    Xia, D
    Sidky, E
    Jiang, TZ
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3773 - 3776
  • [20] Katsevich-type reconstruction for dual helical cone-beam CT
    Zeng, Li
    Zou, Xiaobing
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2010, 18 (04) : 353 - 367