FLUKA Monte Carlo simulation for the Leksell Gamma Knife Perfexion radiosurgery system: Homogeneous media

被引:18
|
作者
Battistoni, Giuseppe [1 ]
Cappucci, Fabrizio [1 ]
Bertolino, Nicola [2 ]
Brambilla, Maria Grazia [3 ]
Mainardi, Hae Song [3 ]
Torresin, Alberto [3 ]
机构
[1] Ist Nazl Fis Nucl, Sect Milan, I-20133 Milan, Italy
[2] IRCCS Neurol Inst C Besta, Dept Hlth, San Giovanni Rotondo, Italy
[3] Osped Niguarda Ca Granda, Dept Med Phys, Milan, Italy
来源
关键词
FLUKA; Monte Carlo; Gamma Knife Perfexion; Stereotactic radiosurgery; MODEL;
D O I
10.1016/j.ejmp.2012.07.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work is to investigate the capability of the FLUKA Monte Carlo (MC) code to simulate the Elekta Leksell Gamma Knife Perfexion (LGK-PFX) and reproduce the Treatment Planning System (TPS) Leksell GammaPlan version 8.2 (LGP) dose calculations for the case of a water equivalent phantom target. Thanks to the collaboration with Elekta Instruments AB, the collimation system geometry, the source positions and all the involved material have been simulated in detail. The relative linear dose distribution along the three coordinate axes, for each collimator size, and the Relative Output Factors (ROF) have been investigated. The simulation has been validated comparing simulated linear dose profiles with measurements performed with EBT radiochromic films. The acceptance criterion between experimental data and FLUKA results is based on the gamma index (GI) method. The FLUKA MC calculation for the ROF provided the values of 0.920 for the 8 mm collimators and 0.800 for the 4 mm collimators. These values are in good agreement with the Elekta reference data of 0.924 and 0.805 respectively. The percentage difference between calculated and reference values for the ROF is under 1% and within the FLUKA uncertainty. Also the simulated relative dose profiles show a good agreement with the LGP calculation expressed by means of the gamma index method. This established accuracy proves that FLUKA is a suitable and powerful tool in order to reproduce successfully the LGP calculations for the homogeneous media. (C) 2012 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:656 / 661
页数:6
相关论文
共 50 条
  • [1] FLUKA MONTE CARLO SIMULATION FOR THE LEKSELL GAMMA KNIFE PERFEXION: HOMOGENEOUS MEDIA.
    Battistoni, G.
    Bertolino, N.
    Brambilla, M. G.
    Cappucci, F.
    Mainardi, H. S.
    Torresin, A.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S176 - S176
  • [2] A Monte Carlo model and its commissioning for the Leksell Gamma Knife Perfexion radiosurgery system
    Yuan, Jiankui
    Machtay, Mitchell
    MEDICAL PHYSICS, 2017, 44 (09) : 4910 - 4918
  • [3] Development of a Monte Carlo model for treatment planning dose verification of the Leksell Gamma Knife Perfexion radiosurgery system
    Yuan, Jiankui
    Lo, Simon S.
    Zheng, Yiran
    Sohn, Jason W.
    Sloan, Andrew E.
    Ellis, Rodney
    Machtay, Mitchell
    Wessels, Barry
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 190 - 201
  • [4] Monte Carlo simulation of the Leksell gamma Knife®:: II.: Effects of heterogeneous versus homogeneous media for stereotactic radiosurgery
    Moskvin, V
    Timmerman, R
    DesRosiers, C
    Randall, M
    DesRosiers, P
    Dittmer, P
    Papiez, L
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (21): : 4879 - 4895
  • [5] Monte Carlo simulation of the Leksell Gamma Knife®:: I.: Source modelling and calculations in homogeneous media
    Moskvin, V
    DesRosiers, C
    Papiez, L
    Timmerman, R
    Randall, M
    DesRosiers, P
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (12): : 1995 - 2011
  • [6] Inhomogeneity Correction using Monte Carlo Simulation for Leksell Gamma Knife Stereotactic Radiosurgery
    Moskvin, V. P.
    Henderson, M. A.
    Barriger, B.
    Can, M.
    DesRosiers, C.
    Johnstone, P. A. S.
    Das, I. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S680 - S680
  • [7] GEANT4-based Monte Carlo Simulation of Beam Quality Correction Factors for the Leksell Gamma Knife® Perfexion
    Schaarschmidt, Thomas
    Kim, Tae Hoon
    Kim, Yong Kyun
    Yang, Hye Jeong
    Chung, Hyun-Tai
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 73 (12) : 1814 - 1820
  • [8] Monte Carlo Modeling of the Gamma Knife Perfexion
    Best, R.
    Bennett, M.
    Gersh, J.
    Wiant, D.
    Bourland, J.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [9] GEANT4-based Monte Carlo Simulation of Beam Quality Correction Factors for the Leksell Gamma Knife® Perfexion™
    Thomas Schaarschmidt
    Tae Hoon Kim
    Yong Kyun Kim
    Hye Jeong Yang
    Hyun-Tai Chung
    Journal of the Korean Physical Society, 2018, 73 : 1814 - 1820
  • [10] Characterization of Gamma Knife Perfexion™ source based on Monte Carlo simulation
    Junios, J.
    Irhas, I.
    Novitrian, N.
    Soediatmoko, E.
    Haryanto, F.
    Su'ud, Z.
    Fielding, A. L.
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2020, 13 (04) : 398 - 404