FLUKA Monte Carlo simulation for the Leksell Gamma Knife Perfexion radiosurgery system: Homogeneous media

被引:18
|
作者
Battistoni, Giuseppe [1 ]
Cappucci, Fabrizio [1 ]
Bertolino, Nicola [2 ]
Brambilla, Maria Grazia [3 ]
Mainardi, Hae Song [3 ]
Torresin, Alberto [3 ]
机构
[1] Ist Nazl Fis Nucl, Sect Milan, I-20133 Milan, Italy
[2] IRCCS Neurol Inst C Besta, Dept Hlth, San Giovanni Rotondo, Italy
[3] Osped Niguarda Ca Granda, Dept Med Phys, Milan, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2013年 / 29卷 / 06期
关键词
FLUKA; Monte Carlo; Gamma Knife Perfexion; Stereotactic radiosurgery; MODEL;
D O I
10.1016/j.ejmp.2012.07.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work is to investigate the capability of the FLUKA Monte Carlo (MC) code to simulate the Elekta Leksell Gamma Knife Perfexion (LGK-PFX) and reproduce the Treatment Planning System (TPS) Leksell GammaPlan version 8.2 (LGP) dose calculations for the case of a water equivalent phantom target. Thanks to the collaboration with Elekta Instruments AB, the collimation system geometry, the source positions and all the involved material have been simulated in detail. The relative linear dose distribution along the three coordinate axes, for each collimator size, and the Relative Output Factors (ROF) have been investigated. The simulation has been validated comparing simulated linear dose profiles with measurements performed with EBT radiochromic films. The acceptance criterion between experimental data and FLUKA results is based on the gamma index (GI) method. The FLUKA MC calculation for the ROF provided the values of 0.920 for the 8 mm collimators and 0.800 for the 4 mm collimators. These values are in good agreement with the Elekta reference data of 0.924 and 0.805 respectively. The percentage difference between calculated and reference values for the ROF is under 1% and within the FLUKA uncertainty. Also the simulated relative dose profiles show a good agreement with the LGP calculation expressed by means of the gamma index method. This established accuracy proves that FLUKA is a suitable and powerful tool in order to reproduce successfully the LGP calculations for the homogeneous media. (C) 2012 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:656 / 661
页数:6
相关论文
共 50 条
  • [31] Monte Carlo calculated output factors of a Leksell Gamma Knife unit
    Cheung, JYC
    Yu, KN
    Ho, RTK
    Yu, CP
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (12): : N247 - N249
  • [32] Variability in target delineation for cavernous sinus meningioma and anaplastic astrocytoma in stereotactic radiosurgery with Leksell Gamma Knife Perfexion
    Sandstrom, Helena
    Nordstrom, Hakan
    Johansson, Jonas
    Kjall, Per
    Jokura, Hidefumi
    Toma-Dasu, Iuliana
    ACTA NEUROCHIRURGICA, 2014, 156 (12) : 2303 - 2313
  • [33] Leksell gamma knife radiosurgery for trigeminal schwannoma
    Hynkova, M.
    Liscak, R.
    Urgosik, D.
    Vymazal, J.
    CESKA A SLOVENSKA NEUROLOGIE A NEUROCHIRURGIE, 2007, 70 (02) : 178 - 185
  • [34] Variability in target delineation for cavernous sinus meningioma and anaplastic astrocytoma in stereotactic radiosurgery with Leksell Gamma Knife Perfexion
    Helena Sandström
    Håkan Nordström
    Jonas Johansson
    Per Kjäll
    Hidefumi Jokura
    Iuliana Toma-Dasu
    Acta Neurochirurgica, 2014, 156 : 2303 - 2313
  • [35] USEFUL BASE PLATE TO SUPPORT THE HEAD DURING LEKSELL SKULL FRAME PLACEMENT IN GAMMA KNIFE PERFEXION RADIOSURGERY
    Nakazawa, Hisato
    Mori, Yoshimasa
    Hagiwara, Masahiro
    Tsugawa, Takahiko
    Shibamoto, Yuta
    Kobayashi, Tatsuya
    Hashizume, Chisa
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2014, 76 (1-2): : 27 - 33
  • [36] On the development of a comprehensive MC simulation model for the Gamma Knife Perfexion radiosurgery unit
    Pappas, E. P.
    Moutsatsos, A.
    Pantelis, E.
    Zoros, E.
    Georgiou, E.
    Torrens, M.
    Karaiskos, P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (03): : 1182 - 1203
  • [37] Dosimetric comparison of the Leksell Gamma Knife Perfexion and 4C
    Novotny, Josef, Jr.
    Bhatnagar, Jagdish P.
    Niranjan, Ajay
    Quader, Mubina A.
    Huq, M. Saiful
    Bednarz, Greg
    Flickinger, John C.
    Kondziolka, Douglas
    Lunsford, L. Dade
    JOURNAL OF NEUROSURGERY, 2008, 109 : 8 - 14
  • [38] Comparison of CT and MRI Based Monte Carlo Simulation for Gamma Knife Stereotactic Radiosurgery
    Xiong, W.
    Huang, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [39] A modular Geant4 model of Leksell Gamma Knife Perfexion™
    Pipek, J.
    Novotny, J.
    Novotny, J., Jr.
    Kozubikova, P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (24): : 7609 - 7623
  • [40] Long-term stability of the Leksell Gamma Knife® Perfexion™ patient positioning system (PPS)
    Novotny, J., Jr.
    Bhatnagar, J. P.
    Xu, Y.
    Huq, M. S.
    MEDICAL PHYSICS, 2014, 41 (03)