Computer-aided detection of masses in full-field digital mammography using screen-film mammograms for training

被引:17
|
作者
Kallenberg, Michiel [1 ]
Karssemeijer, Nico [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Radiol, NL-6525 GA Nijmegen, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2008年 / 53卷 / 23期
关键词
D O I
10.1088/0031-9155/53/23/015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It would be of great value when available databases of screen-film mammography (SFM) images can be used to train full-field digital mammography (FFDM) computer-aided detection (CAD) systems, as compilation of new databases is costly. In this paper, we investigate this possibility. Firstly, we develop a method that converts an FFDM image into an SFM-like representation. In this conversion method, we establish a relation between exposure and optical density by simulation of an automatic exposure control unit. Secondly, we investigate the effects of using the SFM images as training samples compared to training with FFDM images. Our FFDM database consisted of 266 cases, of which 102 were biopsy-proven malignant masses and 164 normals. The images were acquired with systems of two different manufacturers. We found that, when we trained our FFDM CAD system with a small number of images, training with FFDM images, using a five-fold crossvalidation procedure, outperformed training with SFM images. However, when the full SFM database, consisting of 348 abnormal cases (including 204 priors) and 810 normal cases, was used for training, SFM training outperformed FFDMA training. These results show that an existing CAD system for detection of masses in SFM can be used for FFDM images without retraining.
引用
收藏
页码:6879 / 6891
页数:13
相关论文
共 50 条
  • [21] Impact of breast density on computer-aided detection in full-field digital mammography
    Obenauer, Silvia
    Sohns, Christian
    Werner, Carola
    Grabbe, Eckhardt
    JOURNAL OF DIGITAL IMAGING, 2006, 19 (03) : 258 - 263
  • [22] Application of computer-aided diagnosis to full-field digital mammography
    Yarusso, LM
    Nishikawa, RM
    Papaioannou, J
    Nagel, R
    Jokich, P
    Venta, LA
    IWDM 2000: 5TH INTERNATIONAL WORKSHOP ON DIGITAL MAMMOGRAPHY, 2001, : 421 - 426
  • [23] Detection of Breast Cancer with a Computer-Aided Detection Applied to Full-Field Digital Mammography
    Murakami, Ryusuke
    Kumita, Shinichiro
    Tani, Hitomi
    Yoshida, Tamiko
    Sugizaki, Kenichi
    Kuwako, Tomoyuki
    Kiriyama, Tomonari
    Hakozaki, Kenta
    Okazaki, Emi
    Yanagihara, Keiko
    Iida, Shinya
    Haga, Shunsuke
    Tsuchiya, Shinichi
    JOURNAL OF DIGITAL IMAGING, 2013, 26 (04) : 768 - 773
  • [24] Detection of Breast Cancer with a Computer-Aided Detection Applied to Full-Field Digital Mammography
    Ryusuke Murakami
    Shinichiro Kumita
    Hitomi Tani
    Tamiko Yoshida
    Kenichi Sugizaki
    Tomoyuki Kuwako
    Tomonari Kiriyama
    Kenta Hakozaki
    Emi Okazaki
    Keiko Yanagihara
    Shinya Iida
    Shunsuke Haga
    Shinichi Tsuchiya
    Journal of Digital Imaging, 2013, 26 : 768 - 773
  • [25] Performance comparison of full-field digital mammography to screen-film mammography in clinical practice
    Berns, EA
    Hendrick, RE
    Cutter, GR
    MEDICAL PHYSICS, 2002, 29 (05) : 830 - 834
  • [26] Clinical comparison of full-field digital mammography and screen-film mammography of breast cancer
    Lewin, JM
    D'Orsi, CJ
    Hendrick, RE
    Moss, LJ
    Isaacs, PK
    Karellas, A
    Cutter, GR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (03) : 671 - 677
  • [27] Microcalcification detection in full-field digital mammograms: A fully automated computer-aided system
    Basile, T. M. A.
    Fanizzi, A.
    Losurdo, L.
    Bellotti, R.
    Bottigli, U.
    Dentamaro, R.
    Didonna, V
    Fausto, A.
    Massafra, R.
    Moschetta, M.
    Tamborra, P.
    Tangaro, S.
    La Forgia, D.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 1 - 9
  • [28] Low-contrast lesion detection: Comparison of screen-film and full-field digital mammography
    Hendrick, RE
    Berns, E
    Chorbajian, B
    Choi, K
    Lewin, JM
    Sisney, GA
    RADIOLOGY, 1997, 205 : 569 - 569
  • [29] Causes of differences between full-field digital mammography and screen-film mammography interpretations in the Colorado/Massachusetts full-field digital mammography screening trial
    Lewin, JM
    D'Orsi, CJ
    Isaacs, P
    Moss, LJ
    Hendrick, RE
    RADIOLOGY, 2000, 217 : 199 - 199
  • [30] Comparative study in patients with microcalcifications: full-field digital mammography vs screen-film mammography
    Fischer, U
    Baum, F
    Obenauer, S
    Luftner-Nagel, S
    von Heyden, D
    Vosshenrich, R
    Grabbe, E
    EUROPEAN RADIOLOGY, 2002, 12 (11) : 2679 - 2683