Study of the ITER Stray Magnetic Field Effect on the EU 170-GHz2-MW Coaxial Cavity Gyrotron

被引:5
|
作者
Pagonakis, Ioannis Gr. [1 ]
Li, Fengping [2 ]
Illy, Stefan [1 ]
Piosczyk, Bernhard [1 ]
Alberti, Stefano [2 ]
Hogge, Jean-Philippe [2 ]
Kern, Stefan [1 ]
Henderson, Mark [3 ]
Darbos, Caroline [3 ]
机构
[1] Karlsruhe Inst Technol KIT, Inst Pulsed Power & Microwave Technol IHM, Assoc Euratom KIT, D-76131 Karlsruhe, Germany
[2] Ecole Polytech Fed Lausanne Ecublens, Assoc Euratom Confederat Suisse, Ctr Rech Phys Plasmas, CH-1015 Lausanne, Switzerland
[3] ITER Org, F-13067 St Paul Les Durance, France
关键词
Electron beams; electron guns; gyrotrons; tokamaks;
D O I
10.1109/TPS.2012.2197420
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
In this paper, the effect of the ITER stray magnetic field (SMF) on the operation of the European gyrotron has been studied. The SMFs include the magnetic field generated by neighboring gyrotrons, the ITER tokamak, and also the field perturbations caused by the ferromagnetic structural materials used in the ECRH building. The 3-D self-consistent electrostatic code ARIADNE has been used for the evaluation of the SMF effect on the electron beam in the cavity and the collector region. It is shown that the beam parameters at the cavity of the gyrotron are not significantly affected by the SMF. On the other hand, the magnetic field lines in the collector region are significantly deformed in the presence of the SMF. A part of the electron beam is guided to the inappropriately cooled part of the collector surface, while the electron beam power is distributed in a significantly smaller area of the collector walls. In addition, the use of an advanced transverse sweeping system is proposed which would allow to compensate the SMF and to improve the collector operation.
引用
收藏
页码:1945 / 1956
页数:12
相关论文
共 50 条
  • [41] Major Progress in the Development of the 2 MW Coaxial-Cavity Gyrotron for ITER
    Rzesnicki, T.
    Piosczyk, B.
    Gantenbein, G.
    Jin, J.
    Kern, S.
    Samartsev, A.
    Thumm, M.
    2009 34TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES, VOLS 1 AND 2, 2009, : 43 - 44
  • [42] Study of 136/170 GHz Dual-Frequency Operation Based on the KIT 2 MW 170 GHz Coaxial-Cavity Pre-Prototype Gyrotron
    Ruess, T.
    Gantenbein, G.
    Illy, S.
    Jin, J.
    Rzesnicki, T.
    Stanculovic, S.
    Thumm, M.
    Jelonnek, J.
    2023 48TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES, IRMMW-THZ, 2023,
  • [43] FEASIBILITY STUDY OF THE EU HOME TEAM ON A 170GHZ 1MW CW GYROTRON FOR ECH ON ITER
    IATROU, CT
    WHALEY, DR
    KERN, S
    THUMM, M
    TRAN, MQ
    MOBIUS, A
    NICKEL, HU
    NORAJITRA, P
    WIEN, A
    TRAN, TM
    MARDION, GB
    PAIN, M
    TONON, G
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 1995, 16 (06): : 1129 - 1158
  • [44] Design Study of Magnetron Injection Guns for a 4 MW 170 GHz Coaxial Gyrotron
    Rode, J. Christian
    Beringer, Matthias H.
    Illy, Stefan
    Kern, Stefan
    Piosczyk, Bernhard
    Thumm, Manfred
    2009 IEEE INTERNATIONAL VACUUM ELECTRONICS CONFERENCE, 2009, : 96 - 97
  • [45] 170 GHz, 2 MW Coaxial Cavity Gyrotron - Test of the RF output system for the first industrial prototype tube
    Rzesnicki, T.
    Jin, J.
    Piosczyk, B.
    Thumm, M.
    Michel, G.
    Wagner, D.
    2006 IEEE INTERNATIONAL VACUUM ELECTRONICS CONFERENCE HELD JOINTLY WITH 2006 IEEE INTERNATIONAL VACUUM ELECTRON SOURCES, 2006, : 415 - +
  • [46] 170 GHz, 2 MW coaxial cavity gyrotron - investigation of the parasitic oscillations and efficiency of the RF-output system
    Rzesnicki, T.
    Piosczyk, B.
    Dammertz, G.
    Gantenbein, G.
    Thumm, M.
    Michel, G.
    EIGHTH IEEE INTERNATIONAL VACUUM ELECTRONICS CONFERENCE, 2007, : 45 - +
  • [47] Experimental results and outlook of the 2 MW 170 GHz Coaxial-Cavity Gyrotron towards long pulse operation
    Ruess, S.
    Rzesnicki, T.
    Pagonakis, I. Gr.
    Kobarg, T.
    Fuchs, M.
    Illy, S.
    Gantenbein, G.
    Thumm, A. M.
    Jelonnek, J.
    2016 GERMAN MICROWAVE CONFERENCE (GEMIC), 2016, : 369 - 372
  • [48] CW Experiments With the EU 1-MW, 170-GHz Industrial Prototype Gyrotron for ITER at KIT
    Ioannidis, Zisis C.
    Rzesnicki, Tomasz
    Albajar, F.
    Alberti, S.
    Avramidis, Konstantinos A.
    Bin, William
    Bonicelli, T.
    Bruschi, Alessandro
    Chelis, Ioannis
    Frigot, P. -E.
    Gantenbein, Gerd
    Hermann, V.
    Hogge, J. -P.
    Illy, Stefan
    Jin, Jianbo
    Jelonnek, John
    Kasparek, W.
    Latsas, G.
    Lechte, C.
    Legrand, F.
    Kobarg, Thorsten
    Pagonakis, Ioannis Gr.
    Rozier, Y.
    Schlatter, C.
    Schmid, Martin
    Tigelis, Ioannis G.
    Thumm, Manfred
    Tran, M. Q.
    Zein, Andy
    Zisis, A.
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2017, 64 (09) : 3885 - 3892
  • [49] Simulations of the Experimental Operation of the EU 170 GHz, 1 MW Short-Pulse Prototype Gyrotron for ITER
    Avramidis, Konstantinos A.
    Pagonakis, Ioannis Gr.
    Chelis, Ioannis G.
    Gantenbein, Gerd
    Ioannidis, Zisis C.
    Peponis, Dimitrios V.
    Rzesnicki, Tomasz
    Jelonnek, John
    2016 41ST INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2016,
  • [50] Performance Expectation and Preparation of the First Experimental Campaign of the KIT 2 MW 170/204 GHz Coaxial-Cavity Gyrotron
    Ruess, Tobias
    Avramidis, Konstantinos A.
    Gantenbein, Gerd
    Ioannidis, Zisis
    Illy, Stefan
    Jin, Jianbo
    Pagonakis, Ioannis Gr
    Rzesnicki, Tomasz
    Thumm, Manfred
    Weggen, Jorg
    Jelonnek, John
    IVEC 2021: 2021 22ND INTERNATIONAL VACUUM ELECTRONICS CONFERENCE, 2021,