Study of the ITER Stray Magnetic Field Effect on the EU 170-GHz2-MW Coaxial Cavity Gyrotron

被引:5
|
作者
Pagonakis, Ioannis Gr. [1 ]
Li, Fengping [2 ]
Illy, Stefan [1 ]
Piosczyk, Bernhard [1 ]
Alberti, Stefano [2 ]
Hogge, Jean-Philippe [2 ]
Kern, Stefan [1 ]
Henderson, Mark [3 ]
Darbos, Caroline [3 ]
机构
[1] Karlsruhe Inst Technol KIT, Inst Pulsed Power & Microwave Technol IHM, Assoc Euratom KIT, D-76131 Karlsruhe, Germany
[2] Ecole Polytech Fed Lausanne Ecublens, Assoc Euratom Confederat Suisse, Ctr Rech Phys Plasmas, CH-1015 Lausanne, Switzerland
[3] ITER Org, F-13067 St Paul Les Durance, France
关键词
Electron beams; electron guns; gyrotrons; tokamaks;
D O I
10.1109/TPS.2012.2197420
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
In this paper, the effect of the ITER stray magnetic field (SMF) on the operation of the European gyrotron has been studied. The SMFs include the magnetic field generated by neighboring gyrotrons, the ITER tokamak, and also the field perturbations caused by the ferromagnetic structural materials used in the ECRH building. The 3-D self-consistent electrostatic code ARIADNE has been used for the evaluation of the SMF effect on the electron beam in the cavity and the collector region. It is shown that the beam parameters at the cavity of the gyrotron are not significantly affected by the SMF. On the other hand, the magnetic field lines in the collector region are significantly deformed in the presence of the SMF. A part of the electron beam is guided to the inappropriately cooled part of the collector surface, while the electron beam power is distributed in a significantly smaller area of the collector walls. In addition, the use of an advanced transverse sweeping system is proposed which would allow to compensate the SMF and to improve the collector operation.
引用
收藏
页码:1945 / 1956
页数:12
相关论文
共 50 条
  • [31] Design Studies of Mini-Channel Cavity Cooling for a 170 GHz, 2 MW Coaxial-Cavity Gyrotron
    Kalaria, Parth C.
    Bruecker, Philipp T.
    Ruess, Sebastian
    Illy, Stefan
    Avramidis, Konstantinos A.
    Gantenbein, Gerd
    Thumm, Manfred
    Jelonnek, John
    2019 INTERNATIONAL VACUUM ELECTRONICS CONFERENCE (IVEC), 2019,
  • [32] First CW Experiments with the EU ITER 1 MW, 170 GHz Industrial Prototype Gyrotron
    Ioannidis, Z. C.
    Rzesnicki, T.
    Avramidis, K.
    Gantenbein, G.
    Illy, S.
    Jin, J.
    Kobarg, T.
    Pagonakis, I. Gr
    Schmid, M.
    Thumm, M.
    Jelonnek, J.
    Vomvoridis, J. L.
    Hermann, V
    Rozier, Y.
    Legrand, F.
    Chelis, J.
    Latsas, G. P.
    Zisis, A.
    Tigelis, I. G.
    Alberti, S.
    Braunmueller, F.
    Hogge, J-P
    Schlatter, C.
    Genoud, J.
    Tran, M. Q.
    Bruschi, A.
    Bin, W.
    Lontano, M.
    Kasparek, W.
    Lechte, C.
    Albajar, F.
    Bonicelli, T.
    Frigot, P-E
    2017 EIGHTEENTH INTERNATIONAL VACUUM ELECTRONICS CONFERENCE (IVEC), 2017,
  • [33] Parameterization Technique for the Preliminary Gun Design of the EU 170GHz 1MW Conventional Cavity Gyrotron for ITER
    Pagonakis, I. Gr.
    Illy, S.
    Silva, M.
    Hogge, J. -Ph.
    Alberti, S.
    Avramides, K. A.
    Piosczyk, B.
    Albajar, F.
    Bonicelli, T.
    2008 33RD INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER AND TERAHERTZ WAVES, VOLS 1 AND 2, 2008, : 199 - +
  • [34] Further Design Steps Towards a 4 MW 170 GHz Coaxial-Cavity Gyrotron
    Beringer, Matthias H.
    Illy, Stefan
    Jin, J.
    Kern, Stefan
    Rode, J. Christian
    Thumm, Manfred
    2009 34TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES, VOLS 1 AND 2, 2009, : 239 - 240
  • [35] Low power measurements on the new RF output system of a 170 GHz, 2 MW coaxial cavity gyrotron
    Rzesnicki, T.
    Jin, J.
    Piosczyk, B.
    Thumm, M.
    Michel, G.
    Wagner, D.
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 2006, 27 (01): : 1 - 11
  • [36] LOW POWER MEASUREMENTS ON THE NEW RF OUTPUT SYSTEM OF A 170 GHZ, 2 MW COAXIAL CAVITY GYROTRON
    T. Rzesnicki
    J. Jin
    B. Piosczyk
    M. Thumm
    G. Michel
    D. Wagner
    International Journal of Infrared and Millimeter Waves, 2006, 27 : 1 - 11
  • [37] Theoretical Investigation on Injection Locking of the EU 170 GHz 2 MW TE34,19-Mode Coaxial-Cavity Gyrotron
    Bruecker, P.
    Avramidis, K. A.
    Marek, A.
    Thumm, M.
    Jelonnek, J.
    2021 46TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER AND TERAHERTZ WAVES (IRMMW-THZ), 2021,
  • [38] Theoretical Study on the Possibility for Stepwise Tuning of the Frequency of the KIT 2 MW 170/204 GHz Coaxial-Cavity Gyrotron
    Ruess, T.
    Avramidis, K. A.
    Gantenbein, G.
    Illy, S.
    Rzesnicki, T.
    Thumm, M.
    Jelonnek, J.
    2020 45TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2020,
  • [39] 170-GHz, 2-MW Coaxial-Cavity Gyrotron Design for Plasma Fusion System
    Kumar, Nitin
    Singh, Udaybir
    Arti
    Bera, Anirban
    Gahlaut, Vishant
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2018, 46 (09) : 3165 - 3172
  • [40] Design Studies of a RF Interaction Cavity for a 4 MW, 170 GHz Triangular Corrugated Coaxial Cavity Gyrotron
    Singh, Sukwinder
    Yuvaraj, S.
    Baghel, Gaurav Singh
    Kartikeyan, M. V.
    2018 IEEE INTERNATIONAL VACUUM ELECTRONICS CONFERENCE (IVEC), 2018, : 35 - 36