Evaluation of Suction Detection During Different Pumping States in an Implantable Rotary Blood Pump

被引:7
|
作者
Ng, Siew-Cheok [1 ]
Lim, Einly [1 ]
Mason, David G. [2 ]
Avolio, Alberto P. [3 ]
Lovell, Nigel H. [4 ]
机构
[1] Univ Malaya, Dept Biomed Engn, Kuala Lumpur 50603, Malaysia
[2] Univ Queensland, Sch Informat Technol & Elect Engn, Brisbane, Qld, Australia
[3] Macquarie Univ, Australian Sch Adv Med, Sydney, NSW 2109, Australia
[4] Univ New S Wales, Grad Sch Biomed Engn, Sydney, NSW, Australia
基金
澳大利亚研究理事会;
关键词
Suction detection; Implantable rotary blood pump; Pumping states; LEFT-VENTRICULAR ASSIST; CLASSIFICATION;
D O I
10.1111/aor.12079
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In recent times, the problem of noninvasive suction detection for implantable rotary blood pumps has attracted substantial research interest. Here, we compare the performance of various suction indices for different types of suction and non-suction events based on pump speed irregularity. A total of 171 different indices that consist of previously proposed as well as newly introduced suction indices are tested using regularized logistic regression. These indices can be classified as amplitude based (derived from the mean, maximum, and minimum values of a cycle), duration based (derived from the duration of a cycle), gradient based (derived from the first order as well as higher order differences) and frequency based (derived from the power spectral density). The non-suction event data consists of ventricular ejection with or without arrhythmia and intermittent and continuous non-opening of the aortic valve. The suction event data consists of partial ventricular collapse that occurs intermittently as well as continuously with or without arrhythmia. In addition, we also attempted to minimize the usage of multiple indices by applying the sequential forward floating selection method to find which combination of indices gives the best performance. In general, the amplitude-based and gradient-based indices performed quite well while the duration-based and frequency-based indices performed poorly. By having only two indices ([i] the maximum gradient change in positive slope; and [ii] the standard deviation of the maximum value in a cycle), we were able to achieve a sensitivity of 98.9% and a specificity of 99.7%.
引用
收藏
页码:E145 / E154
页数:10
相关论文
共 50 条
  • [31] Experimental Determination of the Normalized Index of Hemolysis for the Sputnik Implantable Pediatric Rotary Blood Pump
    Bockeria L.A.
    Bockeria O.L.
    Selishchev S.V.
    Telyshev D.V.
    Le T.G.
    Satyukova A.S.
    Shvartz V.A.
    Glushko L.A.
    [J]. Biomedical Engineering, 2017, 50 (6) : 416 - 419
  • [32] Sensorless estimation of inlet pressure in implantable rotary blood pump for heart failure patients
    Alomari, A. H.
    Savkin, A. V.
    Ayre, P. J.
    Lim, E.
    Lovell, N. H.
    [J]. ELECTRONICS LETTERS, 2010, 46 (07) : 481 - 482
  • [34] Design and Computational Evaluation of a Pediatric MagLev Rotary Blood Pump
    Tompkins, Landon H.
    Gellman, Barry N.
    Morello, Gino F.
    Prina, Steven R.
    Roussel, Thomas J.
    Kopechek, Jonathan A.
    Petit, Priscilla C.
    Slaughter, Mark S.
    Koenig, Steven C.
    Dasse, Kurt A.
    [J]. ASAIO JOURNAL, 2021, 67 (09) : 1026 - 1035
  • [35] A discriminant-analysis-based suction detection system for rotary blood pumps
    Ferreira, Antonio
    Chen, Shaohui
    Simaan, Marwan A.
    Boston, J. Robert
    Antaki, James F.
    [J]. 2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 4773 - +
  • [36] Rule-based controller based on suction detection for rotary blood pumps
    Ferreira, Antonio
    Boston, J. Robert
    Antaki, James F.
    [J]. 2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 3978 - 3981
  • [37] Estimation of pump flow rate and abnormal condition of implantable rotary blood pumps during long-term in vivo study
    Nakata, K
    Yosikawa, M
    Takano, T
    Sankai, Y
    Ohtsuka, G
    Glueck, J
    Fujisawa, A
    Makinouchi, K
    Yokokawa, M
    Nosé, Y
    [J]. ARTIFICIAL ORGANS, 2000, 24 (04) : 315 - 319
  • [38] Noninvasive average flow estimation for an implantable rotary blood pump: A new algorithm incorporating the role of blood viscosity
    Malagutti, Nicolo
    Karantonis, Dean M.
    Cloherty, Shaun L.
    Ayre, Peter J.
    Mason, David G.
    Salamonsen, Robert F.
    Lovell, Nigel H.
    [J]. ARTIFICIAL ORGANS, 2007, 31 (01) : 45 - 52
  • [39] DEVELOPMENT OF THE MARSEILLES PULSATILE ROTARY BLOOD PUMP FOR PERMANENT IMPLANTABLE LEFT-VENTRICULAR ASSISTANCE
    MONTIES, JR
    HAVLIK, P
    MESANA, T
    TRINKL, J
    TOURRES, JL
    DEMUNCK, JL
    [J]. ARTIFICIAL ORGANS, 1994, 18 (07) : 506 - 511
  • [40] A Method for Control of an Implantable Rotary Blood Pump for Heart Failure Patients Using Noninvasive Measurements
    Lim, Einly
    Alomari, Abdul-Hakeem H.
    Savkin, Andrey V.
    Dokos, Socrates
    Fraser, John F.
    Timms, Daniel L.
    Mason, David G.
    Lovell, Nigel H.
    [J]. ARTIFICIAL ORGANS, 2011, 35 (08) : E174 - E180