Influencing factors on thermal performance of countflow cooling tower

被引:0
|
作者
Zhang, Changxing [1 ]
Hu, Songtao [1 ]
机构
[1] Xian Univ Architecture & Technol, Sch Environm & Municipal Engn, Xian, Peoples R China
关键词
wet-bulb temperature of ambient air; airflow rate; water flow rate; heat rejection rate;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Cooling towers are commonly used to dissipate heat from heat sources to heat sink (ambient environment). Their applications are typically in Heating Ventilation and Air Conditioning (HVAC) systems. They normally consume around ten percent of the whole system energy, at that time, their operation has significant effect on the energy consumption of related other subsystems. This paper presents a countflow cooling tower model which can emulate the parameters' variation accurately during cooling towers' operation. Wet-bulb temperature of ambient air, airflow rate and cooling water flow rate are important factors influencing thermal performance, therefore, in this paper the variations of thermal performance corresponding to the different parameters' variations are calculated and analyzed. Especially, the impact of cooling water flow rate and airflow rate on heat rejection rate is key to minimize energy consumption. The conclusion shows the sum of energy consumption from the pump and fan corresponding to cooling water flow rate and airflow rate exists the minimum (optimal operating point) when wet-bulb temperature of ambient air is a fixed value. When the ambient wet-bulb temperature changes, the optimal operating point of cooling towers will change accordingly, which is helpful to minimize energy consumption and realize the efficient operation of HVAC system.
引用
收藏
页码:1452 / 1459
页数:8
相关论文
共 50 条
  • [31] EXPERIMENTAL INVESTIGATION OF THE THERMAL PERFORMANCE OF WET COOLING TOWER WITH SPLASH FILLS PACKING
    Ahmed, Shaymaa A.
    Aljaberi, Forat Yasir
    Makki, Hasan F.
    THERMAL SCIENCE, 2022, 26 (02): : 1603 - 1613
  • [32] AN ANALYTICAL MODEL ON THERMAL PERFORMANCE EVALUATION OF COUNTER FLOW WET COOLING TOWER
    Wang, Qian
    Wang, Pei-Hong
    Su, Zhi-Gang
    THERMAL SCIENCE, 2017, 21 (06): : 2491 - 2501
  • [33] Performance of a novel natural draft hybrid cooling tower for thermal power generation
    Wei, Huimin
    Huang, Xianwei
    Chen, Lin
    Yang, Lijun
    Du, Xiaoze
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 5231 - 5237
  • [34] Performance of cooling tower in south of Tunisia
    Kairouani, L
    Hassairi, M
    Tarek, Z
    BUILDING AND ENVIRONMENT, 2004, 39 (03) : 351 - 355
  • [35] EVAPORATIVE COOLING TOWER PERFORMANCE PREDICTIONS
    SAVERY, CW
    HAMMILL, MP
    MECHANICAL ENGINEERING, 1973, 95 (06) : 62 - 62
  • [36] PERFORMANCE PREDICTED FOR COOLING-TOWER
    不详
    OIL & GAS JOURNAL, 1979, 77 (07) : 139 - 139
  • [37] Uncertainty analysis of cooling tower performance
    Hennon, K
    Wheeler, D
    PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 58, PTS I AND II, 1996, 58 : 501 - 510
  • [38] TEST COOLING-TOWER PERFORMANCE
    BURGER, R
    HYDROCARBON PROCESSING, 1987, 66 (12): : 32 - 33
  • [39] PERFORMANCE OF COUNTERFLOW COOLING TOWER CELLS
    WRINKLE, RB
    CHEMICAL ENGINEERING PROGRESS, 1971, 67 (07) : 45 - &
  • [40] Performance characteristics of a shower cooling tower
    Qi, Xiaoni
    Liu, Zhenyan
    Li, Dandan
    ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (01) : 193 - 203