Influencing factors on thermal performance of countflow cooling tower

被引:0
|
作者
Zhang, Changxing [1 ]
Hu, Songtao [1 ]
机构
[1] Xian Univ Architecture & Technol, Sch Environm & Municipal Engn, Xian, Peoples R China
关键词
wet-bulb temperature of ambient air; airflow rate; water flow rate; heat rejection rate;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Cooling towers are commonly used to dissipate heat from heat sources to heat sink (ambient environment). Their applications are typically in Heating Ventilation and Air Conditioning (HVAC) systems. They normally consume around ten percent of the whole system energy, at that time, their operation has significant effect on the energy consumption of related other subsystems. This paper presents a countflow cooling tower model which can emulate the parameters' variation accurately during cooling towers' operation. Wet-bulb temperature of ambient air, airflow rate and cooling water flow rate are important factors influencing thermal performance, therefore, in this paper the variations of thermal performance corresponding to the different parameters' variations are calculated and analyzed. Especially, the impact of cooling water flow rate and airflow rate on heat rejection rate is key to minimize energy consumption. The conclusion shows the sum of energy consumption from the pump and fan corresponding to cooling water flow rate and airflow rate exists the minimum (optimal operating point) when wet-bulb temperature of ambient air is a fixed value. When the ambient wet-bulb temperature changes, the optimal operating point of cooling towers will change accordingly, which is helpful to minimize energy consumption and realize the efficient operation of HVAC system.
引用
收藏
页码:1452 / 1459
页数:8
相关论文
共 50 条
  • [21] Cooling Tower Performance Response
    Schwedler, Mick
    ASHRAE JOURNAL, 2014, 56 (03) : 16 - 16
  • [22] Influencing factors analysis of cooling power of air cooling personal thermal protective equipment
    Guo X.-M.
    Yuan X.-G.
    Yuhang Xuebao/Journal of Astronautics, 2010, 31 (01): : 276 - 281
  • [24] Influence mechanism of the louver on the thermal performance of the mechanical draft wet cooling tower
    Deng, Weipeng
    Sun, Fengzhong
    Wang, Runchen
    He, Keting
    APPLIED THERMAL ENGINEERING, 2023, 230
  • [25] Effect of Fouling on the Thermal Performance of Condensers and on the Water Consumption in Cooling Tower Systems
    Cremaschi, Lorenzo
    Wu, Xiaoxiao
    HEAT TRANSFER ENGINEERING, 2015, 36 (7-8) : 663 - 675
  • [26] Experimental study on the thermal performance of a mechanical cooling tower with different drift eliminators
    Lucas, M.
    Martinez, P. J.
    Viedma, A.
    ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (03) : 490 - 497
  • [27] A simplified method on thermal performance capacity evaluation of counter flow cooling tower
    Asvapoositkul, Wanchai
    Treeutok, Supawat
    APPLIED THERMAL ENGINEERING, 2012, 38 : 160 - 167
  • [28] Theoretical Investigation on Thermal Performance of New Structure Closed Wet Cooling Tower
    Zhou, Yasu
    Zhu, Xun
    Ding, Xiao
    HEAT TRANSFER ENGINEERING, 2018, 39 (05) : 460 - 472
  • [29] Effect of fill length and distribution system on the thermal performance of an inverted cooling tower
    Navarro, P.
    Ruiz, J.
    Kaiser, A. S.
    Lucas, M.
    APPLIED THERMAL ENGINEERING, 2023, 231
  • [30] Innovative correlation for calculating thermal performance of counterflow wet-cooling tower
    Mansour, M. Khamis
    Hassab, M. A.
    ENERGY, 2014, 74 : 855 - 862