Precise Measurement of the Hydrogen Isotope Composition of Phyllosilicates by Continuous Flow Off-Axis Integrated Cavity Output Spectroscopy

被引:8
|
作者
Mering, John A. [1 ]
Barker, Shaun L. L. [1 ]
机构
[1] Univ Waikato, Sch Sci, Hamilton 3240, New Zealand
关键词
GYPSUM HYDRATION WATER; LASER SPECTROSCOPY; CLAY-MINERALS; HYDROTHERMAL SYSTEMS; STABLE-ISOTOPES; WS-CRDS; FRACTIONATION; DELTA-O-18; O-18/O-16; OXYGEN;
D O I
10.1021/acs.analchem.7b04992
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New methodology is presented for analyzing hydrogen isotope ratios (D/H) in phyllosilicate minerals by laser absorption spectroscopy. D/H measurements were carried out using an off-axis integrated cavity output spectroscopy (OA-ICOS) instrument operated in a continuous flow configuration. Water was extracted from minerals in a high temperature quartz column and advanced to the analyzer in a dry air carrier gas stream. We report the first D/H measurements by a laser system for serpentine, muscovite, sericite, talc, and biotite, We also measure kaolinite, gypsum, and small volumes of water. Materials, excluding biotite, were calibrated to within 1.5%o of IRMS-measured delta D-VSMOW values, with an average precision of 1.1 parts per thousand. Biotite delta D measurements were up to 10 parts per thousand more positive than established IRMS values, due to partial reduction of evolved waters by Fe in the high temperature column. We provide recommendations for overcoming redox interference for measurements of biotite, and other ferrous materials, by OA-ICOS. Rapid, precise, and accurate analyses were carried out on water volumes as low as 0.25 mu L extracted from minerals. With the exception of talc, the time required for thermal dewatering and measurement is 140 s, which translates into a throughput of up to 6 mineral samples per hour, including replicates. By demonstrating high precision, rapid throughput, low cost, and ease of operation, we provide a tool that should enable researchers at institutions with limited funding to routinely measure D/H in hydrous minerals. The protocols presented herein should also be useful to commercial users seeking to produce high density isotope data sets relevant to exploration of hydrothermal ore deposits and geothermal fields.
引用
收藏
页码:2852 / 2859
页数:8
相关论文
共 50 条
  • [21] Measurement of CO2 by Wavelength Modulated Reinjection Off-Axis Integrated Cavity Output Spectroscopy at 2 μm
    Yuan, Zihao
    Huang, Yinbo
    Lu, Xingji
    Huang, Jun
    Liu, Qiang
    Qi, Gang
    Cao, Zhensong
    ATMOSPHERE, 2021, 12 (10)
  • [22] Detection of Methane Hydrate in Deep Sea Based on Off-Axis Integrated Cavity Output Spectroscopy
    Dong Yang
    Wang Jingjing
    Zhou Xinyu
    Zhu Gongdong
    Qu Kang
    Wu Xiang'en
    Lu Wanjun
    Wen Mingming
    Tan Tu
    Liu Kun
    Gao Xiaoming
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2020, 47 (08):
  • [23] Optical re-injection in Off-Axis Integrated Cavity Output Spectroscopy, modelling and experiments
    Nadeem, Faisal
    Mandon, Julien
    Cristescu, Simona M.
    Harren, Frans J. M.
    2018 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2018,
  • [24] Detection of formaldehyde using off-axis integrated cavity output spectroscopy with an interband cascade laser
    Miller, J. H.
    Bakhirkin, Y. A.
    Ajtai, T.
    Tittel, F. K.
    Hill, C. J.
    Yang, R. Q.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 85 (2-3): : 391 - 396
  • [25] Trace methane gas detection by wavelength modulated off-axis integrated cavity output spectroscopy
    Lai, Rong
    He, Chao
    Li, Xin
    Zhu, Zhengguang
    JOURNAL OF MODERN OPTICS, 2019, 66 (06) : 581 - 589
  • [26] Detection of formaldehyde using off-axis integrated cavity output spectroscopy with an interband cascade laser
    J.H. Miller
    Y.A. Bakhirkin
    T. Ajtai
    F.K. Tittel
    C.J. Hill
    R.Q. Yang
    Applied Physics B, 2006, 85 : 391 - 396
  • [27] Measurement of δ18O and δ2H of water and ethanol in wine by Off-Axis Integrated Cavity Output Spectroscopy and Isotope Ratio Mass Spectrometry
    Wang, Xing
    Jansen, Henk G.
    Duin, Haico
    Meijer, Harro A. J.
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2021, 247 (08) : 1899 - 1912
  • [28] Measurement of δ18O and δ2H of water and ethanol in wine by Off-Axis Integrated Cavity Output Spectroscopy and Isotope Ratio Mass Spectrometry
    Xing Wang
    Henk G. Jansen
    Haico Duin
    Harro A. J. Meijer
    European Food Research and Technology, 2021, 247 : 1899 - 1912
  • [29] Spectral contaminant identifier for off-axis integrated cavity output spectroscopy measurements of liquid water isotopes
    Leen, J. Brian
    Berman, Elena S. F.
    Liebson, Lindsay
    Gupta, Manish
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (04):
  • [30] The study of wavelength modulation off-axis integrated cavity output spectroscopy in the case of Lorentzian absorption profile
    Tan, Zhongqi
    Long, Xingwu
    Feng, Xianwang
    Wei, Zhimeng
    OPTICS COMMUNICATIONS, 2011, 284 (03) : 852 - 856