Precise Measurement of the Hydrogen Isotope Composition of Phyllosilicates by Continuous Flow Off-Axis Integrated Cavity Output Spectroscopy

被引:8
|
作者
Mering, John A. [1 ]
Barker, Shaun L. L. [1 ]
机构
[1] Univ Waikato, Sch Sci, Hamilton 3240, New Zealand
关键词
GYPSUM HYDRATION WATER; LASER SPECTROSCOPY; CLAY-MINERALS; HYDROTHERMAL SYSTEMS; STABLE-ISOTOPES; WS-CRDS; FRACTIONATION; DELTA-O-18; O-18/O-16; OXYGEN;
D O I
10.1021/acs.analchem.7b04992
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New methodology is presented for analyzing hydrogen isotope ratios (D/H) in phyllosilicate minerals by laser absorption spectroscopy. D/H measurements were carried out using an off-axis integrated cavity output spectroscopy (OA-ICOS) instrument operated in a continuous flow configuration. Water was extracted from minerals in a high temperature quartz column and advanced to the analyzer in a dry air carrier gas stream. We report the first D/H measurements by a laser system for serpentine, muscovite, sericite, talc, and biotite, We also measure kaolinite, gypsum, and small volumes of water. Materials, excluding biotite, were calibrated to within 1.5%o of IRMS-measured delta D-VSMOW values, with an average precision of 1.1 parts per thousand. Biotite delta D measurements were up to 10 parts per thousand more positive than established IRMS values, due to partial reduction of evolved waters by Fe in the high temperature column. We provide recommendations for overcoming redox interference for measurements of biotite, and other ferrous materials, by OA-ICOS. Rapid, precise, and accurate analyses were carried out on water volumes as low as 0.25 mu L extracted from minerals. With the exception of talc, the time required for thermal dewatering and measurement is 140 s, which translates into a throughput of up to 6 mineral samples per hour, including replicates. By demonstrating high precision, rapid throughput, low cost, and ease of operation, we provide a tool that should enable researchers at institutions with limited funding to routinely measure D/H in hydrous minerals. The protocols presented herein should also be useful to commercial users seeking to produce high density isotope data sets relevant to exploration of hydrothermal ore deposits and geothermal fields.
引用
收藏
页码:2852 / 2859
页数:8
相关论文
共 50 条
  • [11] Wavelength modulation enhanced off-axis integrated cavity output spectroscopy for OH radical measurement at 2.8 μm
    Ngo, Minh-Nhut
    Nguyen-Ba, Tong
    Dewaele, Dorothee
    Cazier, Fabrice
    Zhao, Weixiong
    Naehle, Lars
    Chen, Weidong
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 362
  • [12] In Situ Measurement of Dissolved Methane and Carbon Dioxide in Freshwater Ecosystems by Off-Axis Integrated Cavity Output Spectroscopy
    Gonzalez-Valencia, Rodrigo
    Magana-Rodriguez, Felipe
    Gerardo-Nieto, Oscar
    Sepulveda-Jauregui, Armando
    Martinez-Cruz, Karla
    Anthony, Katey Walter
    Baer, Doug
    Thalasso, Frederic
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (19) : 11421 - 11428
  • [13] Denoising Technique in Gas Sensing Based on Off-Axis Integrated Cavity Output Spectroscopy
    Zhang Haipeng
    Zheng Kaiyuan
    Li Junhao
    Liu Zidi
    Li Xiuying
    Zheng Chuantao
    Wang Yiding
    ACTA OPTICA SINICA, 2021, 41 (24)
  • [14] Design considerations in high-sensitivity off-axis integrated cavity output spectroscopy
    Moyer, E. J.
    Sayres, D. S.
    Engel, G. S.
    St. Clair, Jason M.
    Keutsch, F. N.
    Allen, N. T.
    Kroll, J. H.
    Anderson, J. G.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2008, 92 (03): : 467 - 474
  • [15] OPO Based Off-Axis Integrated Cavity Output Spectroscopy for Rapid Chemical Sensing
    Arslanov, D. D.
    Harren, F. J. M.
    Lindsay, I. D.
    Boller, K. J.
    2010 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO) AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (QELS), 2010,
  • [16] Optimum signal-to-noise ratio in off-axis integrated cavity output spectroscopy
    Dyroff, Christoph
    OPTICS LETTERS, 2011, 36 (07) : 1110 - 1112
  • [17] Design considerations in high-sensitivity off-axis integrated cavity output spectroscopy
    E.J. Moyer
    D.S. Sayres
    G.S. Engel
    J.M. St. Clair
    F.N. Keutsch
    N.T. Allen
    J.H. Kroll
    J.G. Anderson
    Applied Physics B, 2008, 92
  • [18] Evaluation of continuous water vapor δD and δ18O measurements by off-axis integrated cavity output spectroscopy
    Kurita, N.
    Newman, B. D.
    Araguas-Araguas, L. J.
    Aggarwal, P.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2012, 5 (08) : 2069 - 2080
  • [19] Measurement of Carbon Isotopes in Methane Based on Off-Axis Integrated Cavity Output Spectroscopy Technology with Booster Optical Amplifier
    Yu Runqing
    Xia Hua
    Sun Pengshuai
    Pang Tao
    Wu Bian
    Zhang Zhirong
    ACTA OPTICA SINICA, 2024, 44 (05)
  • [20] Validation of the doubly labeled water method using off-axis integrated cavity output spectroscopy and isotope ratio mass spectrometry
    Melanson, Edward L.
    Swibas, Tracy
    Kohrt, Wendy M.
    Catenacci, Vicki A.
    Creasy, Seth A.
    Plasqui, Guy
    Wouters, Loek
    Speakman, John R.
    Berman, Elena S. F.
    AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2018, 314 (02): : E124 - E130