摘要
The serviceability of a pulse ionization chamber tilled with liquid deuteromethane (LCD4) is confirmed experimentally. Deuteromethane with a level of electronegative impurities of 3 x 10(-9) equiv. O-2 has been obtained using Ni/SiO2 adsorbent. it is shown that for electric fields up to 3 kV/cm, the electronic properties of LCD4 are close to those of LCH4. The ionization chamber shows an energy resolution of 14%(FWHM) when detecting 1.2 MeV gamma-rays. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:478 / 480
页数:3
相关论文
共 50 条
  • [11] PULSE IONIZATION-CHAMBER FOR FISSION FRAGMENTS COUNTING
    BORCEA, C
    MARINESCU, L
    PETRASCU, M
    SIMION, V
    VOICULESCU, G
    STUDII SI CERCETARI DE FIZICA, 1974, 26 (05): : 557 - 562
  • [12] MOLAR VOLUMES OF LIQUID METHANE AND DEUTEROMETHANE
    FUKS, S
    LEGROS, JC
    BELLEMANS, A
    PHYSICA, 1965, 31 (04): : 606 - +
  • [13] BACKGROUND CURRENT OF LIQUID IONIZATION-CHAMBER
    NAKAYAMA, T
    KAWANO, M
    NUCLEAR INSTRUMENTS & METHODS, 1973, 108 (01): : 203 - 204
  • [14] Investigation of properties of a new liquid ionization chamber
    Elliott, A.
    Stewart, K.
    Seuntjens, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2193 - 2193
  • [15] Study of the liquid-methane ionization chamber
    Tanaka, H
    Ariyoshi, T
    Uemura, T
    Arima, H
    Maehata, K
    Ishibashi, K
    Matsumoto, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 539 (03): : 613 - 621
  • [16] A LIQUID IONIZATION-CHAMBER FOR NEUTRON DOSIMETRY
    CHU, JCH
    GRANT, WH
    ALMOND, PR
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (06): : 1133 - 1148
  • [17] Study of characteristics of a new liquid ionization chamber
    Elliott, A.
    Stewart, K.
    Seuntjens, J.
    MEDICAL PHYSICS, 2006, 33 (07) : 2674 - 2674
  • [18] A LIQUID IONIZATION-CHAMBER USING TETRAMETHYLSILANE
    ENGLER, J
    KEIM, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 223 (01): : 47 - 51
  • [19] FUNCTIONAL CONVERSION OF IONIZATION-CHAMBER CURRENTS TO A PULSE SIGNAL
    MYAZDRIK.GA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1968, (01): : 65 - &
  • [20] A STUDY OF PULSE SHAPES IN A PARALLEL-PLATE IONIZATION CHAMBER
    SHERR, R
    PETERSON, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1947, 18 (08): : 567 - 575