Simultaneous detection of three antineoplastic drugs on gloves by liquid chromatography with diode array detector

被引:0
|
作者
Pimenta de Padua Alcantara, Adelia Maria [1 ]
Vitor, Ricardo Vilela [1 ]
Vieira, Elisabeth Pizzamiglio [1 ]
Martins, Isarita [1 ]
机构
[1] Univ Fed Alfenas, Lab Toxicol Anal, Dept Clin & Toxicol Anal, BR-37130000 Alfenas, MG, Brazil
关键词
Antineoplastic drugs/detection; Gloves/toxicologial analysis; High Performance Liquid Chromatography/toxicologial analysis; Occupational exposure;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The aim of this study was to develop a method for simultaneous detection of antineoplastic drugs on gloves since, in occupational exposure, the main contamination route is through dermal contact, which may occur via prolonged contact with contaminated surfaces or materials. The assay was performed by liquid chromatography using the following conditions for the detection of 5-fluorouracil (5-FU), methotrexate (MTX) and paclitaxel (TAX): diode array detection and UV quantification at 195 nm for TAX, at 265 nm for 5-FU and at 302 nm for MTX; ODS column (250 x 4 mm, 5 mu m) with a similar guard column; mobile phase consisted of water (pH 4)-methanol-acetonitrile (35: 15: 50, v/v/v) with a flow rate of 1 mL min(-1). The method presented a linear range from 0.25 to 20 mu g mL(-1) with r(2) higher than 0.99. Repeatability was <= 15% and satisfactory extraction efficiency was obtained when liquid-liquid extraction with ethyl acetate was used for 5-FU and TAX. Satisfactory solid phase extraction was also achieved with C18 cartridges and elution with methanol for MTX. The diode array detector allowed drug quantification at a concentration >= 0.25 mu g mL(-1) in samples, although detection was possible in samples that presented values of around 0.1 mu g mL(-1). The results obtained suggest that the method developed can be applied for the simultaneous determination of the drugs studied and can be considered useful in exposure assessment for health care workers.
引用
收藏
页码:731 / 740
页数:10
相关论文
共 50 条
  • [1] Simultaneous determination of nine ginsenosides in functional foods by high performance liquid chromatography with diode array detector detection
    Shi, Ying
    Sun, Chengjun
    Zheng, Bo
    Li, Yang
    Wang, Yuan
    [J]. FOOD CHEMISTRY, 2010, 123 (04) : 1322 - 1327
  • [2] Simultaneous separation of antihyperlipidemic drugs by green ultrahigh-performance liquid chromatography-diode array detector method: Improving the health of liquid chromatography
    Alghazi, Mansoor
    Alanazi, Fars
    Mohsin, Kazi
    Siddiqui, Nasir Ali
    Shakeel, Faiyaz
    Haq, Nazrul
    [J]. JOURNAL OF FOOD AND DRUG ANALYSIS, 2017, 25 (02) : 430 - 437
  • [3] Liquid-liquid extraction combined with high performance liquid chromatography-diode array-ultra-violet for simultaneous determination of antineoplastic drugs in plasma
    Sanson, Ananda Lima
    Renno Silva, Suellen Cristina
    Goncalves Martins, Matheus Coutinho
    Giusti-Paiva, Alexandre
    Maia, Patricia Penido
    Martins, Isarita
    [J]. BRAZILIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2011, 47 (02) : 363 - 371
  • [4] FLUORESCENCE DETECTION IN LIQUID-CHROMATOGRAPHY WITH AN INTENSIFIED DIODE-ARRAY DETECTOR
    CECIL, TL
    RUTAN, SC
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 556 (1-2): : 495 - 503
  • [5] Simultaneous Determination of Six Food Additives in Drinks by High Performance Liquid Chromatography Coupled to Diode Array Detector Detection
    Yan, Qinghua
    Yang, Li
    Ma, Xiaoqin
    Feng, Huigen
    [J]. JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2013, 35 (04): : 1060 - 1065
  • [6] A Simultaneous Determination of Principal Compounds in Tokishakuyakusan by High-Performance Liquid Chromatography with Diode Array Detector
    Sumino, Megumi
    Saito, Yuko
    Ikegami, Fumio
    Namiki, Takao
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (02) : 320 - 324
  • [7] Simultaneous determination of seven azole antifungal drugs in serum by ultra-high pressure liquid chromatography and diode array detection
    Mistretta, V.
    Dubois, N.
    Denooz, R.
    Charlier, C.
    [J]. ACTA CLINICA BELGICA, 2014, 69 (01) : 53 - 61
  • [8] DIODE-ARRAY DETECTION IN LIQUID-CHROMATOGRAPHY
    SCHEER, H
    [J]. BIOCHEMICAL SPECTROSCOPY, 1995, 246 : 749 - 758
  • [9] CHARACTERIZATION OF PHOTO-DIODE ARRAY DETECTOR IN LIQUID-CHROMATOGRAPHY
    MILANO, MJ
    LAM, S
    SAVONIS, M
    PAUTLER, DB
    PAV, JW
    GRUSHKA, E
    [J]. JOURNAL OF CHROMATOGRAPHY, 1978, 149 (FEB): : 599 - 614