Simultaneous detection of three antineoplastic drugs on gloves by liquid chromatography with diode array detector

被引:0
|
作者
Pimenta de Padua Alcantara, Adelia Maria [1 ]
Vitor, Ricardo Vilela [1 ]
Vieira, Elisabeth Pizzamiglio [1 ]
Martins, Isarita [1 ]
机构
[1] Univ Fed Alfenas, Lab Toxicol Anal, Dept Clin & Toxicol Anal, BR-37130000 Alfenas, MG, Brazil
关键词
Antineoplastic drugs/detection; Gloves/toxicologial analysis; High Performance Liquid Chromatography/toxicologial analysis; Occupational exposure;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The aim of this study was to develop a method for simultaneous detection of antineoplastic drugs on gloves since, in occupational exposure, the main contamination route is through dermal contact, which may occur via prolonged contact with contaminated surfaces or materials. The assay was performed by liquid chromatography using the following conditions for the detection of 5-fluorouracil (5-FU), methotrexate (MTX) and paclitaxel (TAX): diode array detection and UV quantification at 195 nm for TAX, at 265 nm for 5-FU and at 302 nm for MTX; ODS column (250 x 4 mm, 5 mu m) with a similar guard column; mobile phase consisted of water (pH 4)-methanol-acetonitrile (35: 15: 50, v/v/v) with a flow rate of 1 mL min(-1). The method presented a linear range from 0.25 to 20 mu g mL(-1) with r(2) higher than 0.99. Repeatability was <= 15% and satisfactory extraction efficiency was obtained when liquid-liquid extraction with ethyl acetate was used for 5-FU and TAX. Satisfactory solid phase extraction was also achieved with C18 cartridges and elution with methanol for MTX. The diode array detector allowed drug quantification at a concentration >= 0.25 mu g mL(-1) in samples, although detection was possible in samples that presented values of around 0.1 mu g mL(-1). The results obtained suggest that the method developed can be applied for the simultaneous determination of the drugs studied and can be considered useful in exposure assessment for health care workers.
引用
收藏
页码:731 / 740
页数:10
相关论文
共 50 条
  • [21] Simultaneous determination of synthetic dyes in foodstuffs and beverages by high-performance liquid chromatography coupled with diode-array detector
    Bonan, Stefania
    Fedrizzi, Giorgio
    Menotta, Simonetta
    Elisabetta, Caprai
    [J]. DYES AND PIGMENTS, 2013, 99 (01) : 36 - 40
  • [22] Simultaneous Determination of 20 Food Additives in Drinks by High Performance Liquid Chromatography Coupled with Photo-diode Array Detector
    Ma Kang
    Jiang Xiao-Xiong
    Zhao Min
    Cai Ye-Qiang
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (11) : 1661 - 1667
  • [23] Simultaneous Determination of Multiple Preservatives and Antioxidants in Topical Products by Ultra-Pressure Liquid Chromatography with Photo Diode Array Detector
    Balireddi, Venu
    Tatikonda, Krishna Murthy
    Tirukkovalluri, Siva Rao
    Teja, Surikutchi Bhanu
    Manne, Srikanth
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2015, 38 (14) : 1361 - 1370
  • [24] Simultaneous Determination of 11 Components in Yinzhihuang Preparations and Their Constituent Herbs by High-Performance Liquid Chromatography with Diode Array Detector
    Du, Yan
    Han, Jie
    Sun, Shi-an
    Li, Zheng
    Yang, Fang-xiu
    Dong, Lu-lu
    Yang, Dong-zhi
    Tang, Dao-quan
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2016, 54 (04) : 625 - 632
  • [25] Simultaneous determination of 22 sunscreen agents in cosmetics by ultra -high-performance liquid chromatography using diode array detector
    Zhang Keming
    Deng Ming
    Su Yuanyuan
    Xie Dong
    Xu Youcheng
    Liu Xianghong
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2021, 39 (04) : 415 - 423
  • [26] Simultaneous determination of 9 preservatives in processed foods using high-performance liquid chromatography with photo diode array detector
    Lee, Do-Yeon
    Kim, Min-Hee
    Ahn, Jang-Hyuk
    [J]. ANALYTICAL SCIENCE AND TECHNOLOGY, 2020, 33 (06): : 233 - 239
  • [27] Simultaneous quantification of Gemcitabine and Irinotecan hydrochloride in rat plasma by using high performance liquid chromatography-diode array detector
    Malatesta, L.
    Cosco, D.
    Paolino, D.
    Cilurzo, F.
    Costa, N.
    Di Tullio, A.
    Fresta, M.
    Celia, C.
    Di Marzio, L.
    Locatelli, M.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 159 : 192 - 199
  • [28] Simultaneous quantification of coumarins, flavonoids and limonoids in Fructus Citri Sarcodactylis by high performance liquid chromatography coupled with diode array detector
    Chu, Jun
    Li, Song-Lin
    Yin, Zhi-Qi
    Ye, Wen-Cai
    Zhang, Qing-Wen
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 66 : 170 - 175
  • [29] DEVELOPMENT OF A VALIDATED METHOD FOR SIMULTANEOUS QUANTIFICATION OF CLARITHROMYCIN AND LEVOFLOXACIN BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-DIODE ARRAY DETECTOR
    Ijaz, Qazi Amir
    Abbas, Nasir
    Latif, Sumera
    Hussain, Amjad
    Arshad, Muhammad Sohail
    Ali, Ejaz
    Rashid, Memoona
    Sohail, Kashif
    Riaz, Sohail
    Bukhari, Nadeem Irfan
    [J]. ACTA POLONIAE PHARMACEUTICA, 2020, 77 (06): : 841 - 847
  • [30] Determination of tiagabine in serum by liquid chromatography with diode-array detection
    Wnuk, W
    [J]. THERAPEUTIC DRUG MONITORING, 2003, 25 (04) : 530 - 530