Simultaneous separation of antihyperlipidemic drugs by green ultrahigh-performance liquid chromatography-diode array detector method: Improving the health of liquid chromatography

被引:9
|
作者
Alghazi, Mansoor [1 ]
Alanazi, Fars [1 ]
Mohsin, Kazi [1 ]
Siddiqui, Nasir Ali [2 ]
Shakeel, Faiyaz [1 ,3 ]
Haq, Nazrul [1 ,3 ]
机构
[1] King Saud Univ, Coll Pharm, Dept Pharmaceut, Kayyali Chair Pharmaceut Ind, Riyadh, Saudi Arabia
[2] King Saud Univ, Coll Pharm, Dept Pharmacognosy, Riyadh, Saudi Arabia
[3] King Saud Univ, Ctr Excellence Biotechnol Res, Riyadh 11451, Saudi Arabia
关键词
fenofibrate; green chromatography; resolution; simvastatin; Ultrahigh-performance liquid chromatography-diode array detector; AMINO-ACIDS; SIMVASTATIN; FENOFIBRATE; FORMULATION; ATORVASTATIN; PRAVASTATIN; IMPACT;
D O I
10.1016/j.jfda.2016.03.008
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Statins in combination with fibrates show beneficial effects on the lipoprotein profile of patients because they have positive complimentary effects on lipid profile. A new green ultrahigh-performance liquid chromatography-diode array detector method for simultaneous analysis of simvastatin (SMV) and fenofibrate (FNF) in standard form, marketed formulations, and self-emulsifying drug delivery system formulations was developed and validated in the present investigation. The method utilized C-18 as stationary phase and a combination of methanol: water (8: 2) as an eluent. It was found that selected eluent provided short run time (2.5 minutes), better peak symmetry and satisfactory values of other chromatographic parameters such as resolution (Rs = 2.325), capacity factor (k, 3.0 and 4.2 for SMV and FNF, respectively), selectivity (alpha = 1.4), and number of theoretical plates (N, 4265 and 5285 for SMV and FNF, respectively). An excellent linear relationship (r(2) 0.998 and 0.997 for SMV and FNF, respectively) was observed for linear regression data for the calibration plots. The developed system was validated for accuracy, precision, robustness ((>) 2% for both drugs) and recovery (98e102% for both drugs). Results obtained from the statistical treatment of the values obtained for different parameters proved that the method is suitable, reproducible, and selective for the simultaneous analysis of SMV and FNF in bulk, marketed, and self-emulsifying drug delivery system formulations. The replacement of commonly applied toxic solvents with innocuous and environmentally benign solvents provides a better option than the more toxic processes in drug analysis. Copyright (C) 2016, Food and Drug Administration, Taiwan. Published by Elsevier Taiwan LLC. This is an open access article under the CC BY-NC-ND license.
引用
收藏
页码:430 / 437
页数:8
相关论文
共 50 条
  • [1] High Performance Liquid Chromatography-Diode Array Detector Method for the Determination of Tartrazine and Indigotine
    Yalcin, Guler
    Seyhan, Suleyman
    [J]. ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (16) : 8867 - 8874
  • [2] DEVELOPMENT OF A VALIDATED METHOD FOR SIMULTANEOUS QUANTIFICATION OF CLARITHROMYCIN AND LEVOFLOXACIN BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-DIODE ARRAY DETECTOR
    Ijaz, Qazi Amir
    Abbas, Nasir
    Latif, Sumera
    Hussain, Amjad
    Arshad, Muhammad Sohail
    Ali, Ejaz
    Rashid, Memoona
    Sohail, Kashif
    Riaz, Sohail
    Bukhari, Nadeem Irfan
    [J]. ACTA POLONIAE PHARMACEUTICA, 2020, 77 (06): : 841 - 847
  • [3] High Performance Liquid Chromatography-Diode Array Detector Method for the Simultaneous Determination of Five Compounds in the Pulp and Seed of Sea Buckthorn
    Zhao, Lu
    Wen, E.
    Upur, Halmuart
    Tian, Shuge
    [J]. PHARMACOGNOSY MAGAZINE, 2017, 13 (49) : 136 - 140
  • [4] Simultaneous detection of three antineoplastic drugs on gloves by liquid chromatography with diode array detector
    Pimenta de Padua Alcantara, Adelia Maria
    Vitor, Ricardo Vilela
    Vieira, Elisabeth Pizzamiglio
    Martins, Isarita
    [J]. BRAZILIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2010, 46 (04) : 731 - 740
  • [5] Simultaneous quantification of Gemcitabine and Irinotecan hydrochloride in rat plasma by using high performance liquid chromatography-diode array detector
    Malatesta, L.
    Cosco, D.
    Paolino, D.
    Cilurzo, F.
    Costa, N.
    Di Tullio, A.
    Fresta, M.
    Celia, C.
    Di Marzio, L.
    Locatelli, M.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 159 : 192 - 199
  • [6] Liquid-liquid extraction combined with high performance liquid chromatography-diode array-ultra-violet for simultaneous determination of antineoplastic drugs in plasma
    Sanson, Ananda Lima
    Renno Silva, Suellen Cristina
    Goncalves Martins, Matheus Coutinho
    Giusti-Paiva, Alexandre
    Maia, Patricia Penido
    Martins, Isarita
    [J]. BRAZILIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2011, 47 (02) : 363 - 371
  • [7] Simultaneous determination of four components in commercial analgesic tablets by reversed phase high performance liquid chromatography-diode array detector
    Liu, DJ
    Wang, X
    Sun, JL
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (09) : 1106 - 1108
  • [8] Classification of chili powders by high performance liquid chromatography-diode array detection
    Forgacs, Esther
    Cserhati, Tibor
    [J]. ANALYTICAL LETTERS, 2006, 39 (15) : 2775 - 2785
  • [9] A non-extraction method for the determination of prothionamide in human plasma samples by high performance liquid chromatography-diode array detector
    Ionescu, M
    David, V
    Medvedovici, A
    [J]. REVUE ROUMAINE DE CHIMIE, 2002, 47 (8-9) : 855 - 860
  • [10] Simultaneous determination of four triterpenoids of Ganoderma lucidum by reverse-phase high-performance liquid chromatography-diode array detector
    Li, Ying-Bo
    Liang, Cui-Xia
    Liu, Ru-Ming
    Zhong, Jian-Jiang
    [J]. JOURNAL OF BIOTECHNOLOGY, 2008, 136 : S43 - S43