Effects of pneumoperitoneum and Trendelenburg position on intracranial pressure assessed using different non-invasive methods

被引:80
|
作者
Robba, C. [1 ,6 ]
Cardim, D. [2 ]
Donnelly, J. [2 ]
Bertuccio, A. [3 ]
Bacigaluppi, S. [4 ]
Bragazzi, N. [5 ]
Cabella, B. [2 ]
Liu, X. [2 ]
Matta, B. [1 ]
Lattuada, M. [6 ]
Czosnyka, M. [2 ]
机构
[1] Addenbrookes Hosp, Neurosci Crit Care Unit, Box 1,Hills Rd, Cambridge CB2 0QQ, England
[2] Univ Cambridge, Addenbrookes Hosp, Dept Clin Neurosci, Brain Phys Lab,Div Neurosurg, Hills Rd, Cambridge CB2 0QQ, England
[3] Univ London, St Georges Hosp, Dept Clin Neurosci, Div Neurosurg, London, England
[4] Univ Genoa, Galliera Hosp, Dept Neurosurg, Mura Cappuccine 16, I-16100 Genoa, Italy
[5] Univ Genoa, Sch Publ Hlth, Dept Hlth Sci DISSAL, Via Antonio Pastore 1, I-16132 Genoa, Italy
[6] Galliera Hosp, Dept Anaesthesiol, Mura Cappuccine 16, I-16100 Genoa, Italy
关键词
head-down tilt; intracranial pressure; optic nerve sheath diameter; pneumoperitoneum; transcranial Doppler; NERVE SHEATH DIAMETER; OPTIC-NERVE; PULSATILITY INDEX; RADICAL PROSTATECTOMY; ULTRASONOGRAPHY; SURGERY; ASSOCIATION; SONOGRAPHY;
D O I
10.1093/bja/aew356
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. The laparoscopic approach is becoming increasingly frequent for many different surgical procedures. However, the combination of pneumoperitoneum and Trendelenburg positioning associated with this approach may increase the patient's risk for elevated intracranial pressure (ICP). Given that the gold standard for the measurement of ICP is invasive, little is known about the effect of these common procedures on ICP. Methods. We prospectively studied 40 patients without any history of cerebral disease who were undergoing laparoscopic procedures. Three different methods were used for non-invasive estimation of ICP: ultrasonography of the optic nerve sheath diameter (ONSD); transcranial Doppler-based (TCD) pulsatility index (ICPN); and a method based on the diastolic component of the TCD cerebral blood flow velocity (ICPrvd). The ONSD and TCD were measured immediately after induction of general anaesthesia, after pneumoperitoneum insufflation, after Trendelenburg positioning, and again at the end of the procedure. Results, The ONSD, ICPrvd, and ICPp1 increased significantly after the combination of pneumoperitoneum insufflation and Trendelenburg positioning. The ICPrvd showed an area under the curve of 0.80 [95% confidence interval (CI) 0.70-0.90] to distinguish the stage associated with the application of pneumoperitoneum and Trendelenburg position; ONSD and ICPN showed an area under the curve of 0.75 (95% CI 0.65-0.86) and 0.70 (95% CI 0.58-0.81), respectively. Conclusions. The concomitance of pneumoperitoneum and the Trendelenburg position can increase ICP as estimated with non-invasive methods. In high-risk patients undergoing laparoscopic procedures, non-invasive ICP monitoring through a combination of ONSD ultrasonography and TCD-derived ICPrvd could be a valid option to assess the risk of increased ICP.
引用
收藏
页码:783 / 791
页数:9
相关论文
共 50 条
  • [41] Early prognostic value of non-invasive intracranial pressure methods in brain-injured patients
    Chiara Robba
    Gustavo Frigieri
    Sérgio Brasil
    Fabio S. Taccone
    Intensive Care Medicine, 2022, 48 : 1812 - 1814
  • [42] Non-invasive intracranial pressure analysis in craniosynostosis: an intriguing insight
    Prateek Kumar Panda
    Indar Kumar Sharawat
    Child's Nervous System, 2024, 40 : 977 - 978
  • [43] Invention, development and commercialization of a non-invasive intracranial pressure monitor
    Farmer, Franklin H.
    Yost, William T.
    Cantrell, John H.
    Space Congress Proceedings, 1999,
  • [44] Non-invasive assessment of the incidence of raised intracranial pressure in preeclampsia
    Dubost, C.
    Geeraerts, T.
    Roger-Christophe, S.
    Le Gouez, A.
    Mercier, F.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 168 - 168
  • [45] Non-invasive Biomedical Patch Sensor to Measure Intracranial Pressure
    Griffith, Jacob L.
    Wakim, Andre' A.
    Moore-Jansen, Peer
    Cluff, Kim
    2016 IEEE 13TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2016, : 211 - 211
  • [46] Transcranial Bioimpedance Measurement as a Non-invasive Estimate of Intracranial Pressure
    Hawthorne, Christopher
    Shaw, Martin
    Piper, Ian
    Moss, Laura
    Kinsella, John
    INTRACRANIAL PRESSURE & NEUROMONITORING XVI, 2018, 126 : 89 - 92
  • [47] Non-Invasive Monitoring of Intracranial Pressure in Intensive Care Unit
    Cardim, Danilo
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2021, 168 : S91 - S91
  • [48] A pilot study for continuous non-invasive intracranial pressure screening
    Pose, Fernando
    Videla, Carlos
    Campanini, Giovanni
    Redelico, Francisco O.
    Ciarrocchi, Nicolas
    Computers in Biology and Medicine, 2025, 186
  • [49] Intracranial pressure in microgravity conditions: non-invasive assessment by ophthalmodynamometry
    Draeger, J
    Rumberger, E
    Hechler, B
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1999, 70 (12): : 1227 - 1229
  • [50] Non-Invasive Intracranial Pressure Monitoring and Its Applicability in Spaceflight
    Felix, Hugo
    Oliveira, Edson Santos
    AEROSPACE MEDICINE AND HUMAN PERFORMANCE, 2022, 93 (06) : 517 - 531