Effects of pneumoperitoneum and Trendelenburg position on intracranial pressure assessed using different non-invasive methods

被引:80
|
作者
Robba, C. [1 ,6 ]
Cardim, D. [2 ]
Donnelly, J. [2 ]
Bertuccio, A. [3 ]
Bacigaluppi, S. [4 ]
Bragazzi, N. [5 ]
Cabella, B. [2 ]
Liu, X. [2 ]
Matta, B. [1 ]
Lattuada, M. [6 ]
Czosnyka, M. [2 ]
机构
[1] Addenbrookes Hosp, Neurosci Crit Care Unit, Box 1,Hills Rd, Cambridge CB2 0QQ, England
[2] Univ Cambridge, Addenbrookes Hosp, Dept Clin Neurosci, Brain Phys Lab,Div Neurosurg, Hills Rd, Cambridge CB2 0QQ, England
[3] Univ London, St Georges Hosp, Dept Clin Neurosci, Div Neurosurg, London, England
[4] Univ Genoa, Galliera Hosp, Dept Neurosurg, Mura Cappuccine 16, I-16100 Genoa, Italy
[5] Univ Genoa, Sch Publ Hlth, Dept Hlth Sci DISSAL, Via Antonio Pastore 1, I-16132 Genoa, Italy
[6] Galliera Hosp, Dept Anaesthesiol, Mura Cappuccine 16, I-16100 Genoa, Italy
关键词
head-down tilt; intracranial pressure; optic nerve sheath diameter; pneumoperitoneum; transcranial Doppler; NERVE SHEATH DIAMETER; OPTIC-NERVE; PULSATILITY INDEX; RADICAL PROSTATECTOMY; ULTRASONOGRAPHY; SURGERY; ASSOCIATION; SONOGRAPHY;
D O I
10.1093/bja/aew356
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. The laparoscopic approach is becoming increasingly frequent for many different surgical procedures. However, the combination of pneumoperitoneum and Trendelenburg positioning associated with this approach may increase the patient's risk for elevated intracranial pressure (ICP). Given that the gold standard for the measurement of ICP is invasive, little is known about the effect of these common procedures on ICP. Methods. We prospectively studied 40 patients without any history of cerebral disease who were undergoing laparoscopic procedures. Three different methods were used for non-invasive estimation of ICP: ultrasonography of the optic nerve sheath diameter (ONSD); transcranial Doppler-based (TCD) pulsatility index (ICPN); and a method based on the diastolic component of the TCD cerebral blood flow velocity (ICPrvd). The ONSD and TCD were measured immediately after induction of general anaesthesia, after pneumoperitoneum insufflation, after Trendelenburg positioning, and again at the end of the procedure. Results, The ONSD, ICPrvd, and ICPp1 increased significantly after the combination of pneumoperitoneum insufflation and Trendelenburg positioning. The ICPrvd showed an area under the curve of 0.80 [95% confidence interval (CI) 0.70-0.90] to distinguish the stage associated with the application of pneumoperitoneum and Trendelenburg position; ONSD and ICPN showed an area under the curve of 0.75 (95% CI 0.65-0.86) and 0.70 (95% CI 0.58-0.81), respectively. Conclusions. The concomitance of pneumoperitoneum and the Trendelenburg position can increase ICP as estimated with non-invasive methods. In high-risk patients undergoing laparoscopic procedures, non-invasive ICP monitoring through a combination of ONSD ultrasonography and TCD-derived ICPrvd could be a valid option to assess the risk of increased ICP.
引用
收藏
页码:783 / 791
页数:9
相关论文
共 50 条
  • [21] A Review of the Methods of Non-Invasive Assessment of Intracranial Pressure through Ocular Measurement
    Dong, Jinhui
    Li, Qi
    Wang, Xiaofei
    Fan, Yubo
    BIOENGINEERING-BASEL, 2022, 9 (07):
  • [22] Non-invasive Intracranial Pressure Estimation Using Support Vector Machine
    Chacon, Max
    Pardo, Carlos
    Puppo, Corina
    Curilem, Millaray
    Landerretche, Jean
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 996 - 999
  • [23] Estimation of Intracranial Pressure Using Non-Invasive Monitor and Machine Learning
    Habboub, Ghaith
    Hassett, Catherine
    Kondylis, Efstathios
    Gomes, Joao
    NEUROSURGERY, 2023, 69 : 73 - 74
  • [24] Non-invasive Intracranial Pressure Assessment in Brain Injured Patients Using Ultrasound-Based Methods
    Robba, Chiara
    Cardim, Danilo
    Tajsic, Tamara
    Pietersen, Justine
    Bulman, Michael
    Rasulo, Frank
    Bertuetti, Rita
    Donnelly, Joseph
    Liu Xiuyun
    Czosnyka, Zofia
    Cabeleira, Manuel
    Smielewski, Peter
    Matta, Basil
    Bertuccio, Alessandro
    Czosnyka, Marek
    INTRACRANIAL PRESSURE & NEUROMONITORING XVI, 2018, 126 : 69 - 73
  • [25] Irritative effects of vapours and aerosols of bitumen on the airways assessed by non-invasive methods
    Raulf-Heimsoth M.
    Pesch B.
    Kendzia B.
    Spickenheuer A.
    Bramer R.
    Marczynski B.
    Merget R.
    Brüning T.
    Archives of Toxicology, 2011, 85 (Suppl 1) : S41 - S52
  • [26] Clinical application of non-invasive intracranial pressure measurements
    Sheehan, J. R.
    Liu, X.
    Donnelly, J.
    Cardim, D.
    Czosnyka, M.
    Robba, C.
    BRITISH JOURNAL OF ANAESTHESIA, 2018, 121 (02) : 500 - 501
  • [27] Evoked potentials - non-invasive indicators for intracranial pressure
    Engelhardt, W
    ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 1997, 32 (02): : S250 - +
  • [28] A virtual instrument for non-invasive intracranial pressure detection
    Shuren, Qin
    Zhong, Ji
    2005 IEEE INTELLIGENT DATA ACQUISITION AND ADVANCED COMPUTING SYSTEMS: TECHNOLOGY AND APPLICATIONS, 2005, : 283 - 286
  • [29] Non-invasive technologies for intracranial pressure/volume measurement
    Ragauskas, A
    Petkus, V
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 259 - 262
  • [30] FONTOGRAM - NON-INVASIVE INTRACRANIAL-PRESSURE MONITORING
    BADA, HS
    SALMON, JH
    HAJJAR, WM
    PEDIATRIC RESEARCH, 1977, 11 (04) : 560 - 560