Effects of pneumoperitoneum and Trendelenburg position on intracranial pressure assessed using different non-invasive methods

被引:80
|
作者
Robba, C. [1 ,6 ]
Cardim, D. [2 ]
Donnelly, J. [2 ]
Bertuccio, A. [3 ]
Bacigaluppi, S. [4 ]
Bragazzi, N. [5 ]
Cabella, B. [2 ]
Liu, X. [2 ]
Matta, B. [1 ]
Lattuada, M. [6 ]
Czosnyka, M. [2 ]
机构
[1] Addenbrookes Hosp, Neurosci Crit Care Unit, Box 1,Hills Rd, Cambridge CB2 0QQ, England
[2] Univ Cambridge, Addenbrookes Hosp, Dept Clin Neurosci, Brain Phys Lab,Div Neurosurg, Hills Rd, Cambridge CB2 0QQ, England
[3] Univ London, St Georges Hosp, Dept Clin Neurosci, Div Neurosurg, London, England
[4] Univ Genoa, Galliera Hosp, Dept Neurosurg, Mura Cappuccine 16, I-16100 Genoa, Italy
[5] Univ Genoa, Sch Publ Hlth, Dept Hlth Sci DISSAL, Via Antonio Pastore 1, I-16132 Genoa, Italy
[6] Galliera Hosp, Dept Anaesthesiol, Mura Cappuccine 16, I-16100 Genoa, Italy
关键词
head-down tilt; intracranial pressure; optic nerve sheath diameter; pneumoperitoneum; transcranial Doppler; NERVE SHEATH DIAMETER; OPTIC-NERVE; PULSATILITY INDEX; RADICAL PROSTATECTOMY; ULTRASONOGRAPHY; SURGERY; ASSOCIATION; SONOGRAPHY;
D O I
10.1093/bja/aew356
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. The laparoscopic approach is becoming increasingly frequent for many different surgical procedures. However, the combination of pneumoperitoneum and Trendelenburg positioning associated with this approach may increase the patient's risk for elevated intracranial pressure (ICP). Given that the gold standard for the measurement of ICP is invasive, little is known about the effect of these common procedures on ICP. Methods. We prospectively studied 40 patients without any history of cerebral disease who were undergoing laparoscopic procedures. Three different methods were used for non-invasive estimation of ICP: ultrasonography of the optic nerve sheath diameter (ONSD); transcranial Doppler-based (TCD) pulsatility index (ICPN); and a method based on the diastolic component of the TCD cerebral blood flow velocity (ICPrvd). The ONSD and TCD were measured immediately after induction of general anaesthesia, after pneumoperitoneum insufflation, after Trendelenburg positioning, and again at the end of the procedure. Results, The ONSD, ICPrvd, and ICPp1 increased significantly after the combination of pneumoperitoneum insufflation and Trendelenburg positioning. The ICPrvd showed an area under the curve of 0.80 [95% confidence interval (CI) 0.70-0.90] to distinguish the stage associated with the application of pneumoperitoneum and Trendelenburg position; ONSD and ICPN showed an area under the curve of 0.75 (95% CI 0.65-0.86) and 0.70 (95% CI 0.58-0.81), respectively. Conclusions. The concomitance of pneumoperitoneum and the Trendelenburg position can increase ICP as estimated with non-invasive methods. In high-risk patients undergoing laparoscopic procedures, non-invasive ICP monitoring through a combination of ONSD ultrasonography and TCD-derived ICPrvd could be a valid option to assess the risk of increased ICP.
引用
收藏
页码:783 / 791
页数:9
相关论文
共 50 条
  • [1] Non-Invasive Intracranial Pressure Methods during Pneumoperitoneum in an Animal Model
    Dip, Fernando
    Nguyen, David
    Lomenzo, Emanuele
    Szomstein, Samuel
    Szetter, Eugenia
    Rosenthal, Raul J.
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2014, 219 (03) : S62 - S63
  • [2] Effect of pneumoperitoneum and trendelenburg position on intracranial pressure assessed using transcranial doppler - a prospective observational study
    Joseph, Anu
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL): : 610 - 611
  • [3] Intracranial pressure estimated non-invasively and postoperative outcomes in surgery in the Trendelenburg position with pneumoperitoneum
    Christina von Knorring
    Megan Gjordeni
    Tina Thomsson
    Ann-Charlotte Lindström
    Jakob Pansell
    Journal of Anesthesia, Analgesia and Critical Care, 5 (1):
  • [4] Non-invasive Methods of Estimating Intracranial Pressure
    Rosenberg, Jamie B.
    Shiloh, Ariel L.
    Savel, Richard H.
    Eisen, Lewis A.
    NEUROCRITICAL CARE, 2011, 15 (03) : 599 - 608
  • [5] Non-invasive Methods of Estimating Intracranial Pressure
    Jamie B. Rosenberg
    Ariel L. Shiloh
    Richard H. Savel
    Lewis A. Eisen
    Neurocritical Care, 2011, 15 : 599 - 608
  • [6] Effects of positive end-expiratory pressure on intracranial pressure during pneumoperitoneum and Trendelenburg position in a porcine model
    Bedirli, Nurdan
    Emmez, Gokcen
    Unal, Yusuf
    Tonge, Mehmet
    Emmez, Hakan
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2017, 47 (05) : 1610 - 1615
  • [7] Intracranial Pressure Monitoring: Invasive versus Non-Invasive Methods-A Review
    Raboel, P. H.
    Bartek, J., Jr.
    Andresen, M.
    Bellander, B. M.
    Romner, B.
    CRITICAL CARE RESEARCH AND PRACTICE, 2012, 2012
  • [8] Can optic nerve sheath diameter assess increased intracranial pressure in pneumoperitoneum and trendelenburg position?
    Kamhawy, Ghada A.
    Khamis, Fatma M.
    El-Said, Galal H.
    Hassan, Nada T.
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2019, 35 (01): : 80 - 87
  • [9] EFFECTS OF PNEUMOPERITONEUM AND TRENDELENBURG POSITION ON INTRAOCULAR PRESSURE (IOP) IN ISOFLUORANE ANESTHETISED CATS
    de Souza, Arilton Teodoro
    Garcia, Debora de Oliveira
    Nishimura, Lilian Toshiko
    Magalhaes, Marcos Lucio
    Mattos-Junior, Ewaldo
    Paulino-Junior, Daniel
    Jorge, Adriana Torrecilhas
    Honsho, Cristiane dos Santos
    BIOSCIENCE JOURNAL, 2019, 35 (06): : 1899 - 1906
  • [10] Non-invasive intracranial pressure assessment
    Padayachy, Llewellyn C.
    CHILDS NERVOUS SYSTEM, 2016, 32 (09) : 1587 - 1597