Bone Marrow Metastases: T2-weighted Dixon Spin-Echo Fat Images Can Replace T1-weighted Spin-Echo Images

被引:80
|
作者
Maeder, Yael [1 ]
Dunet, Vincent [1 ]
Richard, Raphael [1 ]
Becce, Fabio [1 ]
Omoumi, Patrick [1 ]
机构
[1] Lausanne Univ Hosp, Dept Diagnost & Intervent Radiol, Rue Bugnon 46, CH-1011 Lausanne, Switzerland
关键词
WHOLE-BODY MRI; PROSTATE-CANCER; AXIAL SKELETON; IN-PHASE; PET-CT; SUPPRESSION; MALIGNANCY; DIAGNOSIS; SEQUENCE; SYSTEM;
D O I
10.1148/radiol.2017170325
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To test the potential of Dixon T2-weighted fat-only sequences to replace T1-weighted sequences for the detection of bone metastases, with the hypothesis that diagnostic performance with an alternative magnetic resonance (MR) imaging protocol (sagittal spin-echo Dixon T2-weighted fat-only and water-only imaging) would not be inferior to that with the standard protocol (sagittal spin-echo T1-weighted and spin-echo Dixon T2-weighted water-only imaging). Materials and Methods: A total of 121 consecutive whole-spine MR imaging examinations (63 men; mean age 6 standard deviation, 61.4 years 6 +/- 11.8) performed for suspected vertebral bone metastases were included in this retrospective, institutional review board-approved study. Quantitative image analysis was performed for 30 randomly selected spine levels. Qualitative analysis was performed separately by two musculoskeletal radiologists, who registered the number of metastases for each spine level. Areas under the curve with the protocols were compared on the basis of nonparametric receiver operating characteristic curve estimations by using a noninferiority test on paired data, with a best valuable comparator as a reference. Interobserver and interprotocol agreement was assessed by using k statistics. Results: Contrast-to-noise ratio was significantly higher on the alternative protocol images than on the standard protocol images (181.1 [95% confidence interval: 140.4, 221.7] vs 84.7 [95% confidence interval: 66.3, 103.1] respectively; P < .001). Diagnostic performance was not significantly inferior with the alternative protocol than with the standard protocol for both readers in a per-patient analysis (sensitivity, 97.9%-98.9% vs 93.6%-97.9%; specificity, 85.2%-92.6% vs 92.6%-96.3%; area under the curve, 0.92-0.96 vs 0.95, respectively; all P <= .02) and a per-spine level analysis (all P < .01). Interobserver and interprotocol agreement was good to very good (k = 0.70-0.81). Conclusion: Dixon T2-weighted fat-only and water-only imaging provide, in one sequence, diagnostic performance similar to that of the standard combination of morphologic sequences for the detection of probable spinal bone metastases, thereby providing an opportunity to reduce imaging time by eliminating the need to perform T1 sequences. (C) RSNA, 2017
引用
收藏
页码:853 / 864
页数:12
相关论文
共 50 条
  • [21] APPLICATION OF FAST SPIN-ECHO T(2)-WEIGHTED IMAGING FOR EXAMINATION OF THE NEUROCRANIUM - COMPARISON WITH THE CONVENTIONAL T(2)-WEIGHTED SPIN-ECHO SEQUENCE
    SIEWERT, C
    HOSTEN, N
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 161 (01): : 44 - 50
  • [22] Comparison of inversion recovery fast spin-echo (FSE) with T2-weighted fat-saturated FSE and T1-weighted MR imaging in bone marrow lesion detection
    Pui, MH
    Chang, SK
    SKELETAL RADIOLOGY, 1996, 25 (02) : 149 - 152
  • [23] Fat-suppressed T2-weighted MR imaging of hepatocellular carcinoma and metastases: Comparison of conventional spin-echo, fast spin-echo, and echoplanar pulse sequences
    Kanematsu, M
    Hoshi, H
    Murakami, T
    Itoh, K
    Hori, M
    Inaba, Y
    Kondo, H
    Yokoyama, R
    Nakamura, H
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (01): : 25 - 32
  • [24] Focal liver lesions: Characterization with conventional spin-echo versus fast spin-echo T2-weighted MR imaging
    Schima, W
    Saini, S
    Echeverri, JA
    Hahn, PF
    Harisinghani, M
    Mueller, PR
    RADIOLOGY, 1997, 202 (02) : 389 - 393
  • [25] Comparison of T2-weighted fast spin-echo and spin-echo MR sequences in the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Accardi, M
    Pappalardo, S
    Sarno, C
    DeMaria, M
    RIVISTA DI NEURORADIOLOGIA, 1997, 10 : 233 - 235
  • [26] T2-weighted MRI for the assessment of joint effusion: Comparative study of conventional spin-echo and fast spin-echo sequences
    Mori, S
    Kaneda, T
    Lee, K
    Kato, M
    Motohashi, J
    Ogura, I
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2004, 97 (06): : 768 - 774
  • [27] Comparison of Spin-Echo T1-and T2-Weighted and Gradient-Echo T1-Weighted Images at 3T in Evaluating Very Preterm Neonates at Term-Equivalent Age
    Sarikaya, B.
    McKinney, A. M.
    Spilseth, B.
    Truwit, C. L.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (05) : 1098 - 1103
  • [28] Imaging of the degenerative spine using a sagittal T2-weighted DIXON turbo spin-echo sequence
    Sollmann, Nico
    Moench, Sebastian
    Riederer, Isabelle
    Zimmer, Claus
    Baum, Thomas
    Kirschke, Jan S.
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 131
  • [29] HYPERSIGNAL OF INTERVERTEBRAL DISKS IN T1-WEIGHTED AND SPIN-ECHO MRI SEQUENCES
    VIGNAUX, O
    SARRAZIN, JL
    CORDOLIANI, YS
    COSNARD, G
    JOURNAL DE RADIOLOGIE, 1994, 75 (6-7): : 363 - 367
  • [30] PROSPECTIVE COMPARISON OF T2-WEIGHTED FAST SPIN-ECHO, WITH AND WITHOUT FAT-SUPPRESSION, AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES IN THE UPPER ABDOMEN
    SCHWARTZ, LH
    SELTZER, SE
    TEMPANY, CMC
    SILVERMAN, SG
    PIWNICAWORMS, DR
    ADAMS, DF
    HERMAN, L
    HERMAN, LT
    HOOSHMAND, R
    RADIOLOGY, 1993, 189 (02) : 411 - 416