Body composition: validity of segmental bioelectrical impedance analysis

被引:0
|
作者
LaForgia, Joe [2 ]
Gunn, Simon M. [1 ]
Withers, Robert T. [1 ]
机构
[1] Flinders Univ S Australia, Sch Educ, Exercise Physiol Lab, Adelaide, SA 5001, Australia
[2] Univ S Australia, Sch Pharm & Med Sci, Adelaide, SA 5001, Australia
基金
英国医学研究理事会;
关键词
total body water; percent body fat; foot-to-foot BIA; four-compartment body composition model; fat free mass;
D O I
暂无
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Bioelectrical impedance analysis (BIA) measures the impedance associated with passage of an alternating current through the body which is proportional to total body water (TBW) and therefore can provide expedient estimates of body composition. However, little validity information is available for commercially available bathroom scale type devices which perform whole body estimates from segmental (lower limb) measurements. This study therefore compared body composition estimates between a commercially available segmental BIA device (Tanita BC-532) and four compartment criterion values. Body composition of nine males and nine females (mean +/- SD: 37.7 +/- 18.7 yr; 170.7 +/- 5.3 cm; 68.38 +/- 9.7 kg) was determined via BIA and a four compartment model incorporating measures of body density, TBW and bone mineral mass. While the mean %BF and fat free mass (FFM) values for both methods were not significantly different, considerable intra-individual differences were observed. BIA values varied from the four compartment values by -3.0 to 4.4 %BF and -3.3 to 1.9 kg FFM. The BIA estimates of TBW were significantly different from the criterion measures and intra-individual differences displayed a large range (-0.6 to 3.6 kg). Significant underestimations of TBW via BIA are concerning given that this is the parameter initially established by this method. Furthermore, the BIA data resulted in a FFM hydration value of 68.5% which was significantly (p < 0.001) lower than the four compartment value of 72.0%. In conclusion, the BIA device tested displayed poor individual accuracy for the estimation of body composition compared with a four compartment criterion method.
引用
下载
收藏
页码:586 / 591
页数:6
相关论文
共 50 条
  • [1] Segmental body composition assessed by bioelectrical impedance analysis and DEXA in humans
    Bracco, D
    Thiebaud, D
    Chiolero, RL
    Landry, M
    Burckhardt, P
    Schutz, Y
    JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (06) : 2580 - 2587
  • [2] Body composition evaluated by segmental bioelectrical impedance analysis in healthy subjects and athletes
    Naka, Tatsuki
    Han, Illyoung
    Keii, Takaaki
    Nishizawa, Miyuki
    Sato, Hitoshi
    Ohno, Makoto
    JAPANESE JOURNAL OF PHYSICAL FITNESS AND SPORTS MEDICINE, 2006, 55 : 49 - 52
  • [3] Validity of segmental multiple-frequency bioelectrical impedance analysis to estimate body composition of adults across a range of body mass indexes
    Shafer, Kimberly J.
    Siders, William A.
    Johnson, LuAnn K.
    Lukaski, Henry C.
    NUTRITION, 2009, 25 (01) : 25 - 32
  • [4] Validity of Bioelectrical Impedance Analysis Instruments for the Measurement of Body Composition in Collegiate Gymnasts
    Barnes, Jeremy T.
    Wagganer, Jason D.
    Loenneke, Jeremy P.
    Williams, Ronald D., Jr.
    Arja, Yugandhar
    Kirby, Graeme W.
    Pujol, Thomas J.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 797 - 797
  • [5] RELIABILITY AND VALIDITY OF BIOELECTRICAL IMPEDANCE IN DETERMINING BODY-COMPOSITION
    JACKSON, AS
    POLLOCK, ML
    GRAVES, JE
    MAHAR, MT
    JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (02) : 529 - 534
  • [6] Development of a Segmental Bioelectrical Impedance Spectroscopy Device for Body Composition Measurement
    Cannon, Thomas
    Choi, JungHun
    SENSORS, 2019, 19 (22)
  • [7] Segmental bioelectrical impedance in the assessment of body composition of Sri Lankan children
    Wickramasinghe, V. P.
    Lamabadusuriya, S. P.
    Cleghorn, G. J.
    Davies, P. S. W.
    JOURNAL OF THE NATIONAL SCIENCE FOUNDATION OF SRI LANKA, 2012, 40 (03): : 231 - 239
  • [8] Bioelectrical impedance analysis in body composition measurement
    不详
    NUTRITION, 1996, 12 (11-12) : 749 - 759
  • [9] Segmental bioelectrical impedance analysis
    De Lorenzo, A
    Andreoli, A
    CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2003, 6 (05): : 551 - 555
  • [10] Accuracy of Segmental Bioelectrical Impedance Analysis for Predicting Body Composition in Pre- and Postmenopausal Women
    Tanaka, Noriko I.
    Hanawa, Satoshi
    Murakami, Haruka
    Cao, Zhen-Bo
    Tanimoto, Michiya
    Sanada, Kiyoshi
    Miyachi, Motohiko
    JOURNAL OF CLINICAL DENSITOMETRY, 2015, 18 (02) : 252 - 259