The Value of 320-Slice Spiral Computed Tomography Perfusion Imaging in Staging and Long-Term Dynamic Evaluation of Breast Cancer

被引:0
|
作者
Geng, Hequn [1 ]
Zhang, Zhilin [2 ]
Zhang, Xiaochen [1 ]
Liang, Zhandong [1 ]
Li, Yong [1 ]
Cui, Shujun [1 ]
机构
[1] Hebei North Univ, Dept Med Imaging, Affiliated Hosp 1, Zhangjiakou 075000, Hebei, Peoples R China
[2] Hebei North Univ, Dept Radiotherapy, Affiliated Hosp 1, Zhangjiakou 075000, Hebei, Peoples R China
关键词
RADIOTHERAPY; TRIAL;
D O I
10.1155/2022/7442123
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The value of 320-slice spiral computed tomography (CT) perfusion imaging in staging and long-term dynamic evaluation of breast cancer was explored. 120 breast cancer patients who underwent preoperative CT examination and were confirmed by surgery and pathology were selected. All patients underwent preoperative TNM staging of breast cancer, with 120 cases in each stage. According to the results of 320-slice spiral CT, the postoperative pathology and surgical methods were compared and analyzed. CT diagnosis of breast cancer showed that T1 sensitivity was 71% and accuracy was 61%, T2 sensitivity was 74% and accuracy was 64%, T3 sensitivity was 94% and the accuracy was 84%, and the T4 sensitivity was 100% and the accuracy was 91%. The sensitivity of N1 stage was 71%, and the accuracy was 61%; and the sensitivity of N2 similar to N3 stage was 81%, and the accuracy was 76%. There were 7 cases of M1 with distant metastasis, the sensitivity was 71%, and the accuracy was 71%. At T1 stage, blood flow (BF) was 39:2 +/- 16:7 mL/min/100 g, blood volume (BV) was 2:66 +/- 1:4 mL/100 g, mean transit time (MTT) was 8:16 +/- 2:7 s, and permeability surface (PS) was 16:6 +/- 9:7 mL/min/100 g. 320-slice spiral CT perfusion imaging technology provided a new diagnostic mode for everyone, which can quantitatively identify breast cancer with multiple parameters, which was of great significance for clinical auxiliary diagnosis.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] LONG-TERM PROGNOSTIC VALUE OF SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY MYOCARDIAL PERFUSION IMAGING AFTER PRIMARY PCI FOR STEMI
    Smit, Jeff
    Hermans, Maaike
    Dimitriu-Leen, Aukelien C.
    van Rosendael, Alexander
    Dibbets-Schneider, Petra
    de Geus-Oei, Lioe-Fee
    Mertens, Bart
    Schalij, Martin
    Bax, Jeroen J.
    Scholte, Arthur
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1499 - 1499
  • [32] The value of whole-brain CT perfusion imaging and CT angiography using a 320-slice CT scanner in the diagnosis of MCI and AD patients
    Bo Zhang
    Guo-jun Gu
    Hong Jiang
    Yi Guo
    Xing Shen
    Bo Li
    Wei Zhang
    European Radiology, 2017, 27 : 4756 - 4766
  • [33] Evaluation of left ventricular volumes and ejection fraction with 320-slice multi-slice computed tomography: a head-to-head comparison to 2D-echocardiography
    De Graaf, F. R.
    Schuijf, J. D.
    Van Velzen, J. E.
    Nucifora, G.
    De Roos, A.
    Jukema, J. W.
    Van der Wall, E. E.
    Bax, J. J.
    EUROPEAN HEART JOURNAL, 2009, 30 : 211 - 211
  • [34] Value of Computed Tomography Perfusion Imaging in Evaluation of Patients with Transient Ischemic Attack
    Zacharatos, Haralabos
    Hassan, Ameer E.
    Chaudhry, Saqib A.
    Qureshi, Mushtaq
    Husain, Rizwan
    Suri, M. Fareed K.
    Ezzeddine, Mustapha A.
    Qureshi, Adnan I.
    STROKE, 2011, 42 (03) : E285 - E286
  • [35] Value of Computed Tomography Perfusion Imaging in Evaluation of Patients with Transient Ischemic Attack
    Chaudhry, Saqib A.
    Zacharatos, Haralabos
    Hassan, Ameer
    Qureshi, Mushtaq
    Husain, Muhammad Rizwan
    Suri, M. Fareed K.
    Ezzeddine, Mustapha A.
    Qureshi, Adnan I.
    NEUROLOGY, 2011, 76 (09) : A312 - A312
  • [36] Quantitative evaluation of right atrial volume and right atrial emptying fraction by 320-slice computed tomography compared with three-dimensional echocardiography
    Takahashi, Akiyo
    Funabashi, Nobusada
    Kataoka, Akihisa
    Yajima, Rei
    Takahashi, Maiko
    Uehara, Masae
    Takaoka, Hiroyuki
    Saito, Mariko
    Yamaguchi, Chiharu
    Lee, Kwangho
    Komuro, Issei
    Nomura, Fumio
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 146 (01) : 96 - 99
  • [37] Utility of 320-Slice Multi-Detector Computed Tomography for the Diagnosis and Evaluation of Cardiac Structures in a Patient With a Double-Chambered Right Ventricle
    Harimura, Yoshie
    Tada, Hiroshi
    Ishizu, Tomoko
    Watabe, Hiroaki
    Tanabe, Kengo
    Yamasaki, Hiro
    Sekiguchi, Yukio
    Seo, Yoshihiro
    Aonuma, Kazutaka
    CIRCULATION JOURNAL, 2011, 75 (11) : 2711 - 2713
  • [38] Effectiveness of magnetic resonance imaging and spiral computed tomography in the staging and treatment prognosis of colorectal cancer
    Bai, Lu-Na
    Zhang, Lu-Xian
    WORLD JOURNAL OF GASTROINTESTINAL SURGERY, 2024, 16 (07):
  • [39] Long-Term Prognostic Value of Appropriate Myocardial Perfusion Imaging
    Koh, Angela S.
    Lye, Weng Kit
    Chia, Shaw Yang
    Salunat-Flores, Jennifer
    Sim, Ling L.
    Keng, Felix Y. J.
    Tan, Ru San
    Chua, Terrance S. J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2017, 119 (12): : 1957 - 1962
  • [40] Assessment of 64-slice spiral computed tomography with perfusion weighted imaging in the early diagnosis of ground-glass opacity lung cancer
    Lv, Yinggang
    Jin, Yurong
    Xu, Dianguo
    Yan, Qiaohuan
    Liu, Guiting
    Zhang, Hui
    Yuan, Dingling
    Bao, Junhui
    JOURNAL OF BUON, 2016, 21 (04): : 954 - 957