The Value of 320-Slice Spiral Computed Tomography Perfusion Imaging in Staging and Long-Term Dynamic Evaluation of Breast Cancer

被引:0
|
作者
Geng, Hequn [1 ]
Zhang, Zhilin [2 ]
Zhang, Xiaochen [1 ]
Liang, Zhandong [1 ]
Li, Yong [1 ]
Cui, Shujun [1 ]
机构
[1] Hebei North Univ, Dept Med Imaging, Affiliated Hosp 1, Zhangjiakou 075000, Hebei, Peoples R China
[2] Hebei North Univ, Dept Radiotherapy, Affiliated Hosp 1, Zhangjiakou 075000, Hebei, Peoples R China
关键词
RADIOTHERAPY; TRIAL;
D O I
10.1155/2022/7442123
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The value of 320-slice spiral computed tomography (CT) perfusion imaging in staging and long-term dynamic evaluation of breast cancer was explored. 120 breast cancer patients who underwent preoperative CT examination and were confirmed by surgery and pathology were selected. All patients underwent preoperative TNM staging of breast cancer, with 120 cases in each stage. According to the results of 320-slice spiral CT, the postoperative pathology and surgical methods were compared and analyzed. CT diagnosis of breast cancer showed that T1 sensitivity was 71% and accuracy was 61%, T2 sensitivity was 74% and accuracy was 64%, T3 sensitivity was 94% and the accuracy was 84%, and the T4 sensitivity was 100% and the accuracy was 91%. The sensitivity of N1 stage was 71%, and the accuracy was 61%; and the sensitivity of N2 similar to N3 stage was 81%, and the accuracy was 76%. There were 7 cases of M1 with distant metastasis, the sensitivity was 71%, and the accuracy was 71%. At T1 stage, blood flow (BF) was 39:2 +/- 16:7 mL/min/100 g, blood volume (BV) was 2:66 +/- 1:4 mL/100 g, mean transit time (MTT) was 8:16 +/- 2:7 s, and permeability surface (PS) was 16:6 +/- 9:7 mL/min/100 g. 320-slice spiral CT perfusion imaging technology provided a new diagnostic mode for everyone, which can quantitatively identify breast cancer with multiple parameters, which was of great significance for clinical auxiliary diagnosis.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Application value of multi-slice spiral computed tomography for imaging determination of metastatic lymph nodes of gastric cancer
    Chun-Lai Dai
    Zhi-Gang Yang
    Li-Ping Xue
    Yu-Mei Li
    World Journal of Gastroenterology, 2013, (34) : 5732 - 5737
  • [22] Diagnostic accuracy of 320-slice dynamic volume computed tomography angiography for detection of coronary artery stenosis compared with selective coronary angiography
    Hao Baoshun
    Liu Xuelian
    Liu Yong
    Yu Shujie
    Liu Dinghui
    Qian Xiaoxian
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (16) : C229 - C229
  • [23] 320-slice Computed Tomography Angiography Imaging Findings and Followup in A Patient with Aortic Coarctation Misdiagnosed as Hypertension: A Case Report and Literature Review
    Wang, Peng
    Jiang, Rui
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (12)
  • [24] Predictive Value of Multi-Slice Computed Tomography (MSCT) for ischemia on myocardial perfusion imaging
    Van Velzen, J. E.
    Schuijf, J. D.
    Van Werkhoven, J. M.
    Boersma, E.
    De Graaf, F. R.
    Stokkel, M. P.
    Kaufmann, P.
    Jukema, J. W.
    Van Der Wall, E. E.
    Bax, J. J.
    EUROPEAN HEART JOURNAL, 2009, 30 : 324 - 324
  • [25] Saphenous vein coronary bypass graft aneurysm with fistula to right atrium demonstrated on dynamic-volume 320-slice computed tomography
    Ko, Brian
    Cochrane, Andrew
    Seneviratne, Sujith
    HEART ASIA, 2011, 3 (01) : 1 - 1
  • [26] Long-term Negative Predictive Value of Stress Myocardial Perfusion Imaging and Coronary Computed Tomography Angiography: A Meta-analysis
    Cantoni, V.
    Green, R.
    Acampa, W.
    Assante, R.
    Zampella, E.
    Gaudieri, V.
    Nappi, C.
    Manganelli, M.
    Petretta, M.
    Cuocolo, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S139 - S139
  • [27] The contrast of radiation dose with three scan modes in 320-slice dynamic volume computed tomography angiography compared with selective coronary angiography
    Liu, Xuelian
    Liang, Limin
    Lian, Xianhui
    Hao, Baoshun
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (16) : C261 - C261
  • [28] Long-Term Prognostic Value of Coronary Computed Tomography Angiography
    Arrey-Mbi T.B.
    Klusewitz S.M.
    Villines T.C.
    Current Treatment Options in Cardiovascular Medicine, 2017, 19 (12)
  • [29] The value of whole-brain CT perfusion imaging and CT angiography using a 320-slice CT scanner in the diagnosis of MCI and AD patients
    Zhang, Bo
    Gu, Guo-jun
    Jiang, Hong
    Guo, Yi
    Shen, Xing
    Li, Bo
    Zhang, Wei
    EUROPEAN RADIOLOGY, 2017, 27 (11) : 4756 - 4766
  • [30] Long-term prognostic value of single-photon emission computed tomography myocardial perfusion imaging after primary PCI for STEMI
    Smit, Jeff M.
    Hermans, Maaike P.
    Dimitriu-Leen, Aukelien C.
    van Rosendael, Alexander R.
    Dibbets-Schneider, Petra
    de Geus-Oei, Lioe-Fee
    Mertens, Bart J.
    Schalij, Martin J.
    Bax, Jeroen J.
    Scholte, Arthur J.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2018, 19 (11) : 1287 - 1293