Impact of upgrade to cardiac resynchronization therapy on ventricular arrhythmia frequency in patients with implantable cardioverter-defibrillators

被引:80
|
作者
Ermis, C
Seutter, R
Zhu, AX
Benditt, LC
VanHeel, L
Sakaguchi, S
Lurie, KG
Lu, F
Benditt, DG
机构
[1] Univ Minnesota, Sch Med, Card Arrhythmia Ctr, Minneapolis, MN USA
[2] St Cloud Hosp, Cent Minnesota Heart Ctr, St Cloud, MN USA
关键词
D O I
10.1016/j.jacc.2005.04.067
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study compared cardiac resynchronization therapys (CRT) impact on ventricular tachyarrhythmia susceptibility in patients who, due to worsening heart failure (HF) symptoms, underwent a replacement of a conventional implantable cardioverter-defibrillator (ICD) with a CRT-ICD. BACKGROUND Cardiac resynchronization therapy is an effective addition to conventional treatment of HF in many patients with left ventricular systolic dysfunction. However, whether CRT-induced improvements in HF status also reduce susceptibility to life-threatening arrhythmias is less certain. METHODS Clinical and ICD electrogram data were evaluated in 18 consecutive ICD patients who underwent an upgrade to CRT-ICD. Pharmacologic HF therapy was not altered during follow-up. The definition of ventricular tachycardia (VT) and ventricular fibrillation (VF) for each patient was as determined by device programming. Statistical comparisons used paired t tests. RESULTS Findings were recorded during two time periods: 47 +/- 21 months (range 24 to 70 months) before and 14 2 months (range 9 to 18 months) after CRT upgrade. At time of upgrade, patient age was 69 +/- 11 years and ejection fraction was 21 +/- 8%. Before CRT the frequency of VT, VF, and appropriate ICD shocks was 0.31 +/- 1.23, 0.047 +/- 0.083, and 0.048 +/- 0.085 episodes/month/patient, respectively. After CRT-ICD, VT and VF arrhythmia burdens and frequency of shocks were respectively 0.13 +/- 0.56, 0.001 +/- 0.004, and 0.003 +/- 0.016 episodes/month/patient (p = 0.59, 0.03, and 0.05 vs. pre-CRT). CONCLUSIONS Arrhythmia frequency and number of appropriate ICD treatments were reduced after upgrade to CRT-ICD for HF treatment. Thus, apart from hemodynamic benefits, CRT may also ameliorate ventricular tachyarrhythmia susceptibility in HF patients.
引用
收藏
页码:2258 / 2263
页数:6
相关论文
共 50 条
  • [41] Sudden Cardiac Death and Implantable Cardioverter-Defibrillators
    Turakhia, Mintu P.
    AMERICAN FAMILY PHYSICIAN, 2010, 82 (11) : 1357 - 1366
  • [42] MORE ON PATIENTS WITH IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS
    EMBIL, JM
    GEDDES, JS
    ANNALS OF INTERNAL MEDICINE, 1995, 123 (11) : 892 - 893
  • [43] Comorbid Hypertension Reduces the Risk of Ventricular Arrhythmia in Chronic Heart Failure Patients with Implantable Cardioverter-Defibrillators
    Huang, Hao
    Deng, Yu
    Cheng, Sijing
    Zhang, Nixiao
    Cai, Minsi
    Niu, Hongxia
    Chen, Xuhua
    Gu, Min
    Liu, Xi
    Yu, Yu
    Hua, Wei
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (10)
  • [44] EFFICACY OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS IN PATIENTS AWAITING CARDIAC TRANSPLANTATION
    PODCZECK, A
    HIEF, C
    JAKL, G
    FROHNER, K
    NURNBERG, M
    KALTENBRUNNER, W
    VEIT, F
    LAUFER, G
    STEINBACH, K
    WIENER KLINISCHE WOCHENSCHRIFT, 1995, 107 (16) : 485 - 488
  • [45] Physiologic cardiac pacing in patients with contemporary implantable cardioverter-defibrillators
    Iskos, D
    Fahy, GJ
    Lurie, KG
    Sakaguchi, S
    Collins, JM
    Fetter, J
    Benditt, DG
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (01): : 66 - 71
  • [46] Efficacy and Safety of Transvenous Lead Extraction at the Time of Upgrade from Pacemakers to Cardioverter-Defibrillators and Cardiac Resynchronization Therapy
    Stefanczyk, Pawel
    Nowosielecka, Dorota
    Polewczyk, Anna
    Jachec, Wojciech
    Glowniak, Andrzej
    Kosior, Jaroslaw
    Kutarski, Andrzej
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2023, 20 (01)
  • [47] Psychosocial impact of pacemakers and implantable cardioverter-defibrillators
    Candinas, R
    Buchi, S
    Klaghofer, R
    Sensky, T
    Buddeberg, C
    Duru, F
    XXI CONGRESS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1999, : 857 - 862
  • [48] Causes of death and mortality in patients with implantable cardioverter defibrillators with and without cardiac resynchronization therapy
    Pournaras, A.
    Kader, R.
    Mattsson, G.
    Magnusson, P.
    EUROPEAN HEART JOURNAL, 2018, 39 : 1228 - 1229
  • [49] Cardiac resynchronization therapy reduces the need for shocks in patients with automated implantable cardioverter defibrillators
    Segerson, NM
    Bader, FM
    Walker, S
    Freedman, RA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 17A - 17A
  • [50] Electroconvulsive Therapy in the Setting of Implantable Cardioverter-Defibrillators
    Davis, Asha
    Zisselman, Marc
    Simmons, Tony
    McCall, W. Vaughn
    McCafferty, John
    Rosenquist, Peter B.
    JOURNAL OF ECT, 2009, 25 (03) : 198 - 201