Impact of upgrade to cardiac resynchronization therapy on ventricular arrhythmia frequency in patients with implantable cardioverter-defibrillators

被引:80
|
作者
Ermis, C
Seutter, R
Zhu, AX
Benditt, LC
VanHeel, L
Sakaguchi, S
Lurie, KG
Lu, F
Benditt, DG
机构
[1] Univ Minnesota, Sch Med, Card Arrhythmia Ctr, Minneapolis, MN USA
[2] St Cloud Hosp, Cent Minnesota Heart Ctr, St Cloud, MN USA
关键词
D O I
10.1016/j.jacc.2005.04.067
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study compared cardiac resynchronization therapys (CRT) impact on ventricular tachyarrhythmia susceptibility in patients who, due to worsening heart failure (HF) symptoms, underwent a replacement of a conventional implantable cardioverter-defibrillator (ICD) with a CRT-ICD. BACKGROUND Cardiac resynchronization therapy is an effective addition to conventional treatment of HF in many patients with left ventricular systolic dysfunction. However, whether CRT-induced improvements in HF status also reduce susceptibility to life-threatening arrhythmias is less certain. METHODS Clinical and ICD electrogram data were evaluated in 18 consecutive ICD patients who underwent an upgrade to CRT-ICD. Pharmacologic HF therapy was not altered during follow-up. The definition of ventricular tachycardia (VT) and ventricular fibrillation (VF) for each patient was as determined by device programming. Statistical comparisons used paired t tests. RESULTS Findings were recorded during two time periods: 47 +/- 21 months (range 24 to 70 months) before and 14 2 months (range 9 to 18 months) after CRT upgrade. At time of upgrade, patient age was 69 +/- 11 years and ejection fraction was 21 +/- 8%. Before CRT the frequency of VT, VF, and appropriate ICD shocks was 0.31 +/- 1.23, 0.047 +/- 0.083, and 0.048 +/- 0.085 episodes/month/patient, respectively. After CRT-ICD, VT and VF arrhythmia burdens and frequency of shocks were respectively 0.13 +/- 0.56, 0.001 +/- 0.004, and 0.003 +/- 0.016 episodes/month/patient (p = 0.59, 0.03, and 0.05 vs. pre-CRT). CONCLUSIONS Arrhythmia frequency and number of appropriate ICD treatments were reduced after upgrade to CRT-ICD for HF treatment. Thus, apart from hemodynamic benefits, CRT may also ameliorate ventricular tachyarrhythmia susceptibility in HF patients.
引用
收藏
页码:2258 / 2263
页数:6
相关论文
共 50 条
  • [21] Life-threatening ventricular arrhythmia detection challenge in implantable cardioverter-defibrillators
    Jia, Zhenge
    Li, Dawei
    Xu, Xiaowei
    Li, Na
    Hong, Feng
    Ping, Lichuan
    Shi, Yiyu
    [J]. NATURE MACHINE INTELLIGENCE, 2023, 5 (05) : 554 - 555
  • [22] Gender differences in ventricular arrhythmia recurrence in patients with coronary artery disease and implantable cardioverter-defibrillators
    Lampert, R
    McPherson, CA
    Clancy, JF
    Caulin-Glaser, TL
    Rosenfeld, LE
    Batsford, WP
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (12) : 2293 - 2299
  • [23] Impact of Implantable Cardioverter-defibrillators on Outcome of Patients With Left Ventricular Assist Devices
    Agrawal, Sahil
    Nanda, Sudip
    Allen, David
    Vefali, Huseng
    Shirani, Jamshid
    [J]. CIRCULATION, 2015, 132
  • [24] Battery longevity in cardiac resynchronization therapy implantable cardioverter defibrillators
    Alam, Mian Bilal
    Munir, Muhammad Bilal
    Rattan, Rohit
    Flanigan, Susan
    Adelstein, Evan
    Jain, Sandeep
    Saba, Samir
    [J]. EUROPACE, 2014, 16 (02): : 246 - 251
  • [25] Efficacy and safety of cardiac rehabilitation in patients with implantable cardioverter defibrillators and cardiac resynchronization therapy
    Brochado, B.
    Santos, M.
    Anjo, D.
    Rodrigues, P.
    Sousa, M. J.
    Viamonte, S.
    Fernandes, J. P.
    Carvalho, H.
    Gomes, L.
    Torres, S.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2013, 12 : S150 - S151
  • [26] Impact of Substrate-Based Ablation of Ventricular Tachycardia on Cardiac Mortality in Patients With Implantable Cardioverter-Defibrillators
    Komatsu, Yuki
    Maury, Philippe
    Sacher, Frederic
    Khairy, Paul
    Daly, Matthew
    Lim, Han S.
    Zellerhoff, Stephan
    Jesel, Laurence
    Rollin, Anne
    Duparc, Alexandre
    Mondoly, Pierre
    Aurillac-Lavignolle, Valerie
    Shah, Ashok
    Denis, Arnaud
    Cochet, Hubert
    Derval, Nicolas
    Hocini, Meleze
    Haissaguerre, Michel
    Jais, Pierre
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (11) : 1230 - 1238
  • [27] The impact of Implantable cardioverter-defibrillators on survival rate of patients awaiting cardiac transplantation
    Ermis, C
    Zadeii, G
    Zhu, AX
    Manson, C
    Benditt, DG
    [J]. CIRCULATION, 2002, 106 (19) : 645 - 645
  • [28] CIRCADIAN VARIATION OF VENTRICULAR ARRHYTHMIAS IN PATIENTS WITH IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS
    SCHOEHL, WH
    TRAPPE, HJ
    [J]. CIRCULATION, 1994, 90 (04) : 499 - 499
  • [29] CIRCADIAN PATTERN OF VENTRICULAR TACHYARRHYTHMIAS IN PATIENTS WITH IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS
    WOOD, MA
    SIMPSON, PM
    LONDON, WB
    STAMBLER, BS
    HERRE, JM
    BERNSTEIN, RC
    ELLEBOGEN, KA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A204 - A204
  • [30] The Effect of Spironolactone on Ventricular Tachyarrhythmias in Patients With Implantable Cardioverter-Defibrillators
    Zarraga, Ignatius Gerardo E.
    Dougherty, Cynthia M.
    MacMurdy, Karen S.
    Raitt, Merritt H.
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (04): : 739 - 747