ESTABLISHMENT OF DIAGNOSTIC REFERENCE LEVELS FOR DENTAL PANORAMIC RADIOGRAPHY IN GREECE

被引:6
|
作者
Manousaridis, G. [1 ,2 ]
Koukorava, C. [1 ,2 ]
Hourdakis, C. J. [1 ]
Kamenopoulou, V. [1 ]
Yakoumakis, E. [2 ]
Tsiklakis, K. [2 ]
机构
[1] Greek Atom Energy Commiss, Athens, Greece
[2] Univ Athens, Athens 11528, Greece
关键词
PRODUCT;
D O I
10.1093/rpd/ncv088
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of the present study was to present the national diagnostic reference levels (DRL) established for panoramic dental examinations in Greece. The establishment of DRL, as a tool for the optimisation of radiological procedures, is a requirement of national regulations. Measurements performed by the Greek Atomic Energy Commission on 90 panoramic systems have been used for the derivation of DRL values. DRL values have been proposed for exposure settings of different patient types (child, small adult and standard adult), both for film and digital imaging. The DRLs for different patient types are grouped in three categories: children, small adults (corresponding to female) and average adults (corresponding to male). Proposed DRLs for these groups are 2.2, 3.3 and 4.1 mGy, respectively. In order to investigate the correlation of DRLs with the available imaging modalities (CR, DR and film), this parameter was taken into account. DR imaging DRL is the lowest at 3.5 mGy, CR imaging the highest at 4.2 mGy and film imaging at 3.7 mGy. In order to facilitate comparison with other studies, kerma-width product values were calculated from K-i, air and field size.
引用
收藏
页码:111 / 114
页数:4
相关论文
共 50 条
  • [21] Dental panoramic radiography in the diagnosis of osteoporosis
    Cakur, B.
    Sahin, A.
    Dagistan, S.
    Altun, O.
    Caglayan, F.
    Miloglu, Oe
    Harorli, A.
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2008, 36 (04) : 792 - 799
  • [22] Dose area product reference levels in dental panoramic radiology
    Tierris, CE
    Yakoumakis, EN
    Bramis, GN
    Georgiou, E
    RADIATION PROTECTION DOSIMETRY, 2004, 111 (03) : 283 - 287
  • [23] OSL dosimeters for dental panoramic radiography
    Gutierrez-Marquez, J. G.
    Avalos-Pina, L. Y.
    Lopez-Valencia, A.
    Palacios-Perez, L. L.
    Vega-Carrillo, H. R.
    Rivera-Montalvo, T.
    APPLIED RADIATION AND ISOTOPES, 2018, 142 : 32 - 37
  • [24] HEAD HOLDER FOR PANORAMIC DENTAL RADIOGRAPHY
    ORDMAN, J
    CLEATONJONES, P
    MIZRAHI, E
    FATTI, LP
    ANGLE ORTHODONTIST, 1987, 57 (04) : 322 - 331
  • [25] Establishment of Diagnostic Reference Levels for Radiography in 10-year-old Pediatric Patients in Republic of Korea
    Lee, Seung-Youl
    Park, Sang-Myeong
    JOURNAL OF MAGNETICS, 2019, 24 (04) : 781 - 788
  • [26] Establishment of local diagnostic reference levels in paediatric screen-film radiography at a children's hospital
    Wambani, J. S.
    Korir, G. K.
    Korir, I. K.
    Kilaha, S.
    RADIATION PROTECTION DOSIMETRY, 2013, 154 (04) : 465 - 476
  • [27] Establishment of CT diagnostic reference levels in Ireland
    Foley, S. J.
    McEntee, M. F.
    Rainford, L. A.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1018): : 1390 - 1397
  • [28] A contribution to the establishment of diagnostic reference levels in CT
    Hatziioannou, K
    Papanastassiou, E
    Delichas, M
    Bousbouras, P
    BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (908): : 541 - 545
  • [29] Attribution of the rise in radiation dose to the relaxed panoramic radiography diagnostic reference level in Korea
    Han, S. J.
    Kim, S.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (01): : 249 - 252
  • [30] Aspects of panoramic radiography in general dental practice
    Rushton, VE
    Horner, K
    Worthington, HV
    BRITISH DENTAL JOURNAL, 1999, 186 (07) : 342 - 344