Total Reflection X-ray Fluorescence Analysis (TXRF) using the high flux SAXS camera

被引:3
|
作者
Wobrauschek, P
Streli, C
Pepponi, G
Bergmann, A
Glatter, O
机构
[1] Univ Vienna, Inst Atom, A-1020 Vienna, Austria
[2] Anton Paar GmbH, Graz, Austria
[3] Inst Chem, Graz, Austria
关键词
The authors would like to thank Walter Drabek from the Atominstitut for the machining of the mechanical components and Rupert Schwarzl from the Institute of Chemistry for his help during the preparation of the experiment and the FWF (# PHY14336) for financial support;
D O I
10.1016/S0168-9002(02)00463-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Combining the high photon flux from a rotating anode X-ray tube with an X-ray optical component to focus and monochromatize the X-ray beam is the most promising instrumentation for best detection limits in the modern XRF laboratory. This is realized by using the design of a high flux SAXS camera in combination with a 4 kW high brilliant rotating Cu anode X-ray tube with a graded elliptically bent multilayer and including a new designed module for excitation in total reflection geometry within the beam path, The system can be evacuated thus reducing absorption and scattering of air and removing the argon peak in the spectra. Another novelty is the use of a Peltier cooled drift detector with an energy resolution of 148 eV at 5.9 keV and 5 mm(2) area. For Co detection limits of about 300 fg determined by a single element standard have been achieved, Testing a real sample NIST 1643d led to detection limits in the range of 300 ng/l for the medium Z. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:569 / 572
页数:4
相关论文
共 50 条
  • [41] The use and function of TXRF (Total Reflection X-ray Fluorescence) for routine in Fab metallic monitoring.
    Allen, M
    Hossain, T
    Lebowitz, J
    IN-LINE CHARACTERIZATION, YIELD RELIABILITY, AND FAILURE ANALYSES IN MICROELECTRONIC MANUFACTURING, 1999, 3743 : 157 - 161
  • [42] Evaluation of the Optimal Dilution Sequence for the Minimization of the Concentration Uncertainty in Total Reflection X-Ray Fluorescence (TXRF)
    Bennun, Leonardo
    Barros, Haydn
    De Araujo, Yulimar
    Vazquez, Cristina
    Piol, Maria Natalia
    Sanhueza, Vilma
    ANALYTICAL LETTERS, 2022, 55 (08) : 1331 - 1347
  • [43] Synchrotron radiation total reflection X-ray fluorescence (SR-TXRF) for evaluation of food contamination
    Vives, A. E. S.
    Moreira, S.
    Brienza, S. M. B.
    Zucchi, O. L. A.
    Nascimento, V. F., Jr.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2006, 270 (01) : 147 - 153
  • [44] Synchrotron radiation total reflection X-ray fluorescence (SR-TXRF) for evaluation of food contamination
    A. E. S. Vives
    S. Moreira
    S. M. B. Brienza
    O. L. A. Zucchi
    V. F. Nascimento Filho
    Journal of Radioanalytical and Nuclear Chemistry, 2006, 270 : 147 - 153
  • [45] TOTAL-REFLECTION X-RAY-FLUORESCENCE ANALYSIS USING SPECIAL X-RAY SOURCES
    WOBRAUSCHEK, P
    KREGSAMER, P
    LADISICH, W
    RIEDER, R
    STRELI, C
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (02) : 143 - 151
  • [46] Total reflection X-ray fluorescence analysis with chemical microchip
    Tsuji, Kouichi
    Hanaoka, Yousuke
    Hibara, Akihide
    Tokeshi, Manabu
    Kitamori, Takehiko
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (04) : 389 - 392
  • [47] Total reflection X-ray fluorescence analysis of Mongolian coals
    Ts. Amartaivan
    E. D. Greaves
    G. Bernasconi
    P. Wobrauschek
    Journal of Radioanalytical and Nuclear Chemistry, 1997, 220 : 249 - 252
  • [48] Mineral analysis of pollen by Total Reflection X-Ray Fluorescence
    Basso, Ines M.
    Lorenzo, Daniel S.
    Mouteira, Maria C.
    Custo, Graciela S.
    APPLIED RADIATION AND ISOTOPES, 2019, 152 : 168 - 171
  • [49] Total reflection X-ray fluorescence analysis of light elements
    Streli, C
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (03) : 281 - 293
  • [50] Total reflection X-ray fluorescence analysis of Mongolian coals
    Amartaivan, T
    Greaves, ED
    Bernasconi, G
    Wobrauschek, P
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1997, 220 (02) : 249 - 252