A MEMS flow sensor applied in a variable-air-volume unit in a building air-conditioning system

被引:18
|
作者
Shikida, M. [1 ]
Yamazaki, Y. [2 ]
Yoshikawa, K. [2 ]
Sato, Kazuo [3 ]
机构
[1] Nagoya Univ, Ctr Micronano Mechatron, Chikusa Ku, Nagoya, Aichi 4648603, Japan
[2] Nagoya Univ, Dept Micronano Syst Engn, Nagoya, Aichi 4648603, Japan
[3] Nagoya Univ, Dept Micronano Syst Engn, MEMS Lab, Nagoya, Aichi 4648603, Japan
关键词
Flow sensor; Air-conditioning network; SHEAR-STRESS SENSOR;
D O I
10.1016/j.sna.2012.10.009
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A MEMS flow sensor was applied in a variable-air-volume (VAV) unit, composed of a butterfly damper and a flow sensor, to precisely control the supply of air in a large-scale air-conditioning network system used in a building. The MEMS flow sensor is composed of a hot-wire anemometer with an underside cavity to shorten the response time, and it was fabricated on a 25-mu m-thick polyimide film by photolithography and film deposition. The total thickness of the sensor structure is only 525 mu m. Four sensors were attached at 90 degrees to each other on the inner surface of an 8-in, duct, and the outputs obtained by the sensors were averaged. The results of an experimental evaluation of the sensor are as follows. First, the averaged sensor output depends on damper angle and the distance of the sensor from the damper. Second, it is higher than that obtained by a similar sensor in a straight duct. Third, a conversion curve was derived and used to calculate flow rate from the obtained outputs of the four sensors fitted in the VAV unit. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:212 / 217
页数:6
相关论文
共 50 条
  • [21] Measuring and Analysis on Energy Consumption of Variable Air Volume (VAV) Central Air-conditioning System
    Ren, Qingchang
    Guo, Shangyi
    Lei, Xiaofeng
    Yan, Weijia
    [J]. SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 516 - 519
  • [22] Using a fan air flow station to control building static pressure in a variable volume air conditioning system
    Zheng, B.
    Pang, X.
    Liu, M.
    Joo, I.
    [J]. Solar Engineering 2005, 2006, : 581 - 587
  • [23] Fuzzy-Neuro Health Monitoring System for HVAC System Variable-Air-Volume Unit
    Allen, William Hand
    Rubaai, Ahmed
    [J]. 2013 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2013,
  • [24] On a control policy that maintains indoor air quality in a variable-air-volume air-handling unit
    Norris, WR
    Sreenivas, RS
    [J]. PROCEEDINGS OF THE 1997 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS, 1997, : 886 - 891
  • [25] Green Building Air Conditioning System with Variable Frequency Drive and Variable Air flow controller
    Poddar, Ankit
    Kaur, Prabhjot
    Jhunjhunwala, Ashok
    [J]. 2016 FIRST INTERNATIONAL CONFERENCE ON SUSTAINABLE GREEN BUILDINGS AND COMMUNITIES (SGBC), 2016,
  • [26] CANPA AIR-CONDITIONING UNIT
    不详
    [J]. MACHINERY AND PRODUCTION ENGINEERING, 1971, 119 (3082): : 824 - &
  • [27] SELECTION OF AN AIR-CONDITIONING UNIT
    STEPHENS, DG
    [J]. REVUE GENERALE DE THERMIQUE, 1969, 8 (94): : 973 - &
  • [28] Online Fault Detection Configuration on Equipment Side of a Variable-Air-Volume Air Handling Unit
    杨学宾
    李鑫海
    杨思钰
    王吉
    罗雯军
    [J]. Journal of Donghua University(English Edition), 2023, 40 (02) : 225 - 231
  • [29] LIMITATIONS AND PROBLEMS OF VARIABLE-AIR-VOLUME SYSTEMS
    HIGHTOWER, G
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1977, 19 (12): : 39 - 39
  • [30] Genetic-algorithm-optimized fuzzy logic control of a variable air volume air-conditioning system
    Huang, Yonghong
    Li, Nianping
    Yu, Tao
    Shi, Yangchun
    [J]. DYNAMICS OF CONTINUOUS DISCRETE AND IMPULSIVE SYSTEMS-SERIES B-APPLICATIONS & ALGORITHMS, 2006, 13E : 2643 - 2647