Beam Monitors for Tomorrow: The Challenges of Electron and Photon FLASH RT

被引:22
|
作者
Vignati, Anna [1 ,2 ]
Giordanengo, Simona [2 ]
Fausti, Federico [2 ,3 ]
Villarreal, Oscar A. Marti [1 ,2 ]
Milian, Felix Mas [1 ,4 ]
Mazza, Giovanni [2 ]
Shakarami, Zahra [1 ,2 ]
Cirio, Roberto [1 ,2 ]
Monaco, Vincenzo [1 ,2 ]
Sacchi, Roberto [1 ,2 ]
机构
[1] Univ Torino, Phys Dept, Turin, Italy
[2] INFN Natl Inst Nucl Phys, Turin Div, Turin, Italy
[3] Devices & Technol Torino Srl, DE TEC TOR, Turin, Italy
[4] Univ Estadual Santa Cruz, Dept Exact & Technol Sci DCET, Ilheus, BA, Brazil
关键词
FLASH RT; electron beams; photon beams; beam monitors; silicon detector; DETECTORS; SENSORS; DESIGN;
D O I
10.3389/fphy.2020.00375
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The emergent FLASH RadioTherapy (RT) uses ultrahigh dose-rate irradiation (up to 10(7)Gy/s instantaneous dose-rate in each mu s pulse) to deliver a single high dose of irradiation in a very short time (<200 ms). Pre-clinical studies at ultrahigh dose-rates recently showed an increased ratio between tumoricidal effect and normal tissue toxicity (therapeutic index), compared to conventional RT at standard Gy/min dose-rates. If confirmed by biologicalin vivovalidations, this could represent a breakthrough in cancer treatment. However, the reliability and the accuracy of experimental studies are nowadays limited by the lack of detectors able to measure online the beam fluence at FLASH dose-rates. The behavior of standard beam monitors (gas-filled ionization chambers) is compromised by the volume recombination caused by the amount of charges created per unit volume and unit time, due to the large dose-rate. Moreover, due to the lack of proper monitoring devices and to the uncertainties of its future applications, very few facilities are able to deliver at present FLASH irradiations. In this contribution, we report about the physical and technological challenges of monitoring high and ultra-high dose-rates with electrons and photon beams, starting from the pre-clinical and clinical constraints for new devices. Based on the extensive experience in silicon detectors for monitoring applications in RT with external beams, the work then investigates silicon sensors as a possible option to tackle such extreme requirements and a rugged thin and large (e.g., 10 x 10 cm(2)) flat detector (silicon-based sensor + readout electronics) is therefore outlined. This study aims at presenting the FLASH-RT dosimetry problem and analyzing the possibilities for a silicon sensor to be employed as sensing device for several FLASH scenarios, including some ideas on the readout part. However, more detailed simulations and studies are demanded to delineate more precisely the technical choices to be undertaken in order to tackle the clinical accuracy required on the beam fluence, typically a few %, during photon and electron high and ultra-high irradiations, the required minimal perturbation of the beam and the high level of radiation resistance.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Unstable matrix equations and their relationship to measuring the emittance of an electron beam using beam position monitors
    Russell, SJ
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 430 (2-3): : 498 - 506
  • [32] Emittance measurements of the Sub-Picosecond Accelerator electron beam using beam position monitors
    Russell, SJ
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (02): : 1362 - 1366
  • [33] TriB-RT: Simultaneous optimization of photon, electron and proton beams
    Kueng, R.
    Mueller, S.
    Loebner, H. A.
    Frei, D.
    Volken, W.
    Aebersold, D. M.
    Stampanoni, M. F. M.
    Fix, M. K.
    Manser, P.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (04):
  • [34] RADIATION SURVEY OF A TRUEBEAM LINAC OPERATING IN ELECTRON FLASH-RT MODE
    Robertson, Andrew K. H.
    Frederick, Amy
    MacMahon, Sheila
    Petric, M. Peter
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S21 - S22
  • [35] Electron flash-RT program in clinical setting for human translation.
    Zhang, Rongxiao
    Rahman, Mahbubur
    Bruza, Petr
    Thomas, Charles R.
    Jarvis, Lesley A.
    Hoopes, P. Jack
    Gladstone, David J.
    Pogue, Brian W.
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2022, 40 (16)
  • [36] ALARA in a Flash - Radiation Shielding and Safety Implications Following Linac Conversion to An Electron FLASH-RT Unit
    Poirier, Y.
    Becker, S.
    Mossahebi, S.
    Lamichhane, N.
    Sawant, A.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E575 - E575
  • [37] Pulse Resolved Beam Characterization and Feedback for FLASH-RT Using Radioluminescent Dosimeters
    Ashraf, M.
    Rahman, M.
    Zhang, R.
    Williams, B.
    Hoopes, J.
    Gladstone, D.
    Pogue, B.
    Bruza, P.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [38] Photon and electron beam dosimetry with a CVD diamond detector
    Fidanzio, A
    Azario, L
    Viola, P
    Ascarelli, P
    Cappelli, E
    Conte, G
    Piermattei, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 524 (1-3): : 115 - 123
  • [39] HIGH-ENERGY PHOTON AND ELECTRON-BEAM
    TAPLEY, NV
    [J]. CANCER, 1977, 39 (02) : 788 - 801
  • [40] ELECTRON CONTAMINATION FROM PHOTON-BEAM COLLIMATORS
    NILSSON, B
    BRAHME, A
    [J]. RADIOTHERAPY AND ONCOLOGY, 1986, 5 (03) : 235 - 244