TriB-RT: Simultaneous optimization of photon, electron and proton beams

被引:0
|
作者
Kueng, R. [1 ,2 ,3 ]
Mueller, S. [1 ,2 ,3 ]
Loebner, H. A. [1 ,2 ,3 ]
Frei, D. [1 ,2 ,3 ]
Volken, W. [1 ,2 ,3 ]
Aebersold, D. M. [1 ,2 ,3 ]
Stampanoni, M. F. M. [4 ,5 ]
Fix, M. K. [1 ,2 ,3 ]
Manser, P. [1 ,2 ,3 ]
机构
[1] Bern Univ Hosp, Div Med Radiat Phys, Inselspital, Bern, Switzerland
[2] Bern Univ Hosp, Dept Radiat Oncol, Inselspital, Bern, Switzerland
[3] Univ Bern, Bern, Switzerland
[4] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[5] Swiss Fed Inst Technol, Zurich, Switzerland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2021年 / 66卷 / 04期
关键词
triple beam radiotherapy; TriB-RT; simultaneous optimization; Monte Carlo;
D O I
10.1088/1361-6560/ab936f
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose. To develop a novel treatment planning process (TPP) with simultaneous optimization of modulated photon, electron and proton beams for improved treatment plan quality in radiotherapy. Methods. A framework for fluence map optimization of Monte Carlo (MC) calculated beamlet dose distributions is developed to generate treatment plans consisting of photon, electron and spot scanning proton fields. Initially, in-house intensity modulated proton therapy (IMPT) plans are compared to proton plans created by a commercial treatment planning system (TPS). A triple beam radiotherapy (TriB-RT) plan is generated for an exemplary academic case and the dose contributions of the three particle types are investigated. To investigate the dosimetric potential, a TriB-RT plan is compared to an in-house IMPT plan for two clinically motivated cases. Benefits of TriB-RT for a fixed proton beam line with a single proton field are investigated. Results. In-house optimized IMPT are of at least equal or better quality than TPS-generated proton plans, and MC-based optimization shows dosimetric advantages for inhomogeneous situations. Concerning TriB-RT, for the academic case, the resulting plan shows substantial contribution of all particle types. For the clinically motivated case, improved sparing of organs at risk close to the target volume is achieved compared to IMPT (e.g. myelon and brainstem Dmax<i -37%) at cost of an increased low dose bath (healthy tissue V-10% +22%). In the scenario of a fixed proton beam line, TriB-RT plans are able to compensate the loss in degrees of freedom to substantially improve plan quality compared to a single field proton plan. Conclusion. A novel TPP which simultaneously optimizes photon, electron and proton beams was successfully developed. TriB-RT shows the potential for improved treatment plan quality and is especially promising for cost-effective single-room proton solutions with a fixed beamline in combination with a conventional linac delivering photon and electron fields.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Development of a Simultaneous Optimization Process for Photon, Electron and Proton Beams (TriB-RT)
    Kueng, R.
    Mueller, S.
    Loebner, H. A.
    Frei, D.
    Volken, W.
    Aebersold, D. M.
    Stampanoni, M. F. M.
    Fix, M. K.
    Manser, P.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E743 - E743
  • [2] COMPUTER OPTIMIZATION FOR THE COMBINING OF ELECTRON AND PHOTON BEAMS
    FIELDS, R
    TAPLEY, ND
    SPANOS, WJ
    CUNDIFF, JH
    SAMPIERE, VA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1980, 6 (10): : 1444 - 1444
  • [3] Simultaneous observation of ultrafast electron and proton beams in TNSA
    Fabrizio Bisesto
    Mario Galletti
    Maria Pia Anania
    Gemma Costa
    Massimo Ferrario
    Riccardo Pompili
    Arie Zigler
    Fabrizio Consoli
    Mattia Cipriani
    Martina Salvadori
    Claudio Verona
    [J]. High Power Laser Science and Engineering, 2020, 8 (02) : 151 - 156
  • [4] Simultaneous observation of ultrafast electron and proton beams in TNSA
    Bisesto, Fabrizio
    Galletti, Mario
    Anania, Maria Pia
    Costa, Gemma
    Ferrario, Massimo
    Pompili, Riccardo
    Zigler, Arie
    Consoli, Fabrizio
    Cipriani, Mattia
    Salvadori, Martina
    Verona, Claudio
    [J]. HIGH POWER LASER SCIENCE AND ENGINEERING, 2020, 8
  • [5] COMPARISON FEATURES FOR PROTON AND HEAVY ION BEAMS VERSUS PHOTON AND ELECTRON BEAMS
    Mihai, M.
    Spunei, M.
    Malaescu, I.
    [J]. ROMANIAN REPORTS IN PHYSICS, 2014, 66 (01) : 212 - 222
  • [6] PHASE-SPACE OCCUPATION OF ELECTRON PROTON + PHOTON BEAMS
    KATZ, R
    CURNUTTE, B
    [J]. AMERICAN JOURNAL OF PHYSICS, 1964, 32 (08) : 617 - &
  • [7] Dosimetric characterization of CVD diamonds in photon, electron and proton beams
    Cirrone, GAP
    Cuttone, G
    Lo Nigro, S
    Mongelli, V
    Raffaele, L
    Sabini, MG
    [J]. NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2006, 150 : 330 - 333
  • [8] POLARIZED PROTON TARGET FOR USE IN INTENSE ELECTRON AND PHOTON BEAMS
    BORGHINI, M
    CHAMBERLAIN, O
    FUZESY, RZ
    GORN, W
    MOREHOUSE, CC
    POWELL, T
    ROBRISH, P
    ROCK, S
    SHANNON, S
    SHAPIRO, G
    WEISBERG, H
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1970, 84 (02): : 168 - +
  • [9] Optimization of combined electron and photon beams for breast cancer
    Xiong, W
    Li, J
    Chen, L
    Price, RA
    Freedman, G
    Ding, M
    Qin, L
    Yang, J
    Ma, CM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (10): : 1973 - 1989
  • [10] Simultaneous optimization of mixed photon energy beams in volumetric modulated arc therapy
    Momin, Shadab
    Grafe, James
    Georgiou, Konstantinos
    Khan, Rao
    [J]. MEDICAL PHYSICS, 2019, 46 (09) : 3844 - 3863