Investigating the use of non-attenuation corrected PET images for the attenuation correction of PET data in PET/MR systems

被引:0
|
作者
Chang, Tingting [1 ]
Clark, John W., Jr. [1 ]
Mawlawi, Osama R. [2 ]
机构
[1] Rice Univ, Dept Elect & Comp Engn, Houston, TX 77005 USA
[2] Dept Imaging Phys, Houston, TX 77030 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
MR-based attenuation correction (AC) in PET/MR imaging is currently evaluated by many groups. The aim of this study is to investigate the feasibility of using the non-attenuated PET images (PET-NAC) as a means for the AC of PET images in PET/MR systems. A water fillable torso phantom with hollow spheres was scanned on a GE Discovery-RX PET/CT scanner. The activity concentration in the spheres and background was 37.2 and 6.27 kBq/cc respectively. A PET scan was acquired in 3D using 2 FOV with 5min / FOV. CT-AC PET (PET-CTAC), PET-NAC, and CT images were generated. In addition the PET-NAC images were used to create an attenuation map through an iterative segmentation process in three steps. In the first step of the process, the phantom body contour was segmented from the PET-NAC image. Voxels inside the contour were then assigned a value of 0.094 cm(-1) to represent the attenuation coefficient of soft tissue at 511 keV. This segmented attenuation map was then used to attenuate correct the raw PET data and the resulting PET images were used as the input to the second step of the process. The lung region was segmented in the second step and voxels were assigned a value of 0.024 cm(-1) representing the attenuation coefficients of lung tissue at 511 keV. The updated attenuation map was then used for a second time to attenuate correct the raw PET data, and the resulting PET images were used as the input to the third step. The purpose of the third step is to delineate parts of the heart and liver from the lung contour since these parts were unavoidably included in the lung contour of the second step. These parts were then corrected by using a value of 0.094 cm(-1) in the attenuation map. Finally the attenuation coefficients of the scanner couch were included based on the CT images to eliminate the impact of the couch on the accuracy of AC. This final attenuation map was then used to attenuate correct the raw PET data and resulted in a final PET image (PET-IAC). Visual inspection and SUV measurements of the spheres between PET-IAC and the PET-CTAC were performed to assess the accuracy of image quantification. Furthermore, our proposed approach was used on two patients with lung and liver tumors to assess its feasibility in clinical studies. The results show that there is very small difference between the PET-IAC and PET-CTAC from visual inspection. PET-IAC SUVs are on average equal to 94 +/- 3% compared to the SUVs from the PET-CTAC in phantom study. For the two patient studies, this value is 111 +/- 12%. In conclusion, the use of PET-NAC as a means for the AC of PET images is feasible in the clinic. Such approach can potentially be an alternative method of MR-based AC in PET/MR imaging.
引用
收藏
页码:3784 / 3787
页数:4
相关论文
共 50 条
  • [31] Enhanced Speed Total Body Imaging for Pediatric Patients with Non-Attenuation Corrected PET Technology
    Hu, Jingxi
    Hu, Ying-ying
    Zhang, Qiyang
    Zhao, Yumo
    Zhang, Xu
    Zhang, Na
    Yang, Jiaqi
    Yang, Yongfeng
    Zheng, Hairong
    Liang, Dong
    He, Xiangjian
    Fan, Wei
    Hu, Zhanli
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [32] Correction for oral contrast artifacts in CT attenuation-corrected PET images obtained by combined PET/CT
    Nehmeh, SA
    Erdi, YE
    Kalaigian, H
    Kolbert, KS
    Pan, TS
    Yeung, H
    Squire, O
    Sinha, A
    Larson, SM
    Humm, JL
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (12) : 1940 - 1944
  • [33] Supplemental transmission method for improved PET attenuation correction on an integrated MR/PET
    Watson, Charles C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 734 : 191 - 195
  • [34] Attenuation correction of PET images with respiration-averaged CT images in PET/CT
    Pan, TS
    Mawlawi, C
    Nehmeh, SA
    Erdi, YE
    Luo, DS
    Liu, HH
    Castillo, R
    Mohan, R
    Liao, ZX
    Macapinlac, HA
    JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (09) : 1481 - 1487
  • [35] Challenges and current methods for attenuation correction in PET/MR
    Vincent Keereman
    Pieter Mollet
    Yannick Berker
    Volkmar Schulz
    Stefaan Vandenberghe
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2013, 26 : 81 - 98
  • [36] Brain PET/MR attenuation correction for pediatric patients
    Ladefoged, C.
    Andersen, J. B.
    Marner, L.
    Hansen, A. E.
    Law, I.
    Hojgaard, L.
    Andersen, F. L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S438 - S438
  • [37] Challenges and current methods for attenuation correction in PET/MR
    Keereman, Vincent
    Mollet, Pieter
    Berker, Yannick
    Schulz, Volkmar
    Vandenberghe, Stefaan
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2013, 26 (01): : 81 - 98
  • [38] Bone attenuation in brain-PET/MR imaging should be accounted for during attenuation correction and PET reconstruction
    Andersen, F. L.
    Keller, S. H.
    Hansen, A. E.
    Beyer, T.
    Law, I.
    Hojgaard, L.
    Holm, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S174 - S174
  • [39] Hybrid approach for attenuation correction in PET/MR scanners
    Santos Ribeiro, A.
    Mops, E. Rota
    Herzog, H.
    Almeida, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 734 : 166 - 170
  • [40] Does non-attenuation correction influence lesion detectability in FDG PET of thyroid cancer.
    Helal, BO
    Trebossen, R
    Pointurier, I
    Delbot, T
    Leperse, V
    Syrota, A
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 319P - 319P