The Application Key Problem and On-site Test Study of Electronic Transformer in Smart Substation

被引:0
|
作者
Yang Huayun [1 ]
Jiang Bo [1 ]
Jiang Wei [1 ]
Aibing [1 ]
Yang Huayun [1 ]
机构
[1] Sichuan Elect Power Res Inst, Chengdu, Peoples R China
关键词
electronic trasnsformer; on-site test; accuracy; smart substation;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
the electronic transformer is one of key equipments in the rapid developing smart substation of power systems. In this paper, the key application problems of the electronic transformer in the developing smart substation are summarized according to the application status in China. In order to guarantee the safe and reliable performance of the electronic instrument transformers in power system, on-site calibration test for electronic instrument s are needed. The on-site calibration test of the electronic instrument transformer in the first smart substation in China is given out. And the test results show that the reliability and accuracy of the electronic instrument transformer are uppermost problems in the developing smart substation.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Application of microbiological rapid on-site evaluation in respiratory intensive care units: a retrospective study
    Tao, Yi
    Song, Licheng
    Fu, Han
    Zhang, Wei
    Song, Yuwei
    Liu, Hongxiang
    Xie, Lixin
    Wang, Kaifei
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2021, 10 (01)
  • [42] Study on S-shaped characteristic of Francis reversible unit by on-site test and CFD simulation
    LI JinWei
    HU QingJuan
    YU JiXing
    LI QiZhang
    [J]. Science China Technological Sciences, 2013, (09) : 2163 - 2169
  • [43] Study on S-shaped characteristic of Francis reversible unit by on-site test and CFD simulation
    LI JinWei
    HU QingJuan
    YU JiXing
    LI QiZhang
    [J]. Science China(Technological Sciences), 2013, 56 (09) : 2163 - 2169
  • [44] Study on S-shaped characteristic of Francis reversible unit by on-site test and CFD simulation
    Li JinWei
    Hu QingJuan
    Yu JiXing
    Li QiZhang
    [J]. SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2013, 56 (09) : 2163 - 2169
  • [45] Study on S-shaped characteristic of Francis reversible unit by on-site test and CFD simulation
    JinWei Li
    QingJuan Hu
    JiXing Yu
    QiZhang Li
    [J]. Science China Technological Sciences, 2013, 56 : 2163 - 2169
  • [46] Study on Waveform Parameters of Impulse Test Voltage and On-Site Docking Method for EHV/UHV GIS
    Liu, Xuandong
    Zhang, Lingli
    Wen, Tao
    Zhang, Qiaogen
    Tan, Xiangyu
    [J]. IEEE ELECTRICAL INSULATION MAGAZINE, 2019, 35 (04) : 9 - 15
  • [47] A "Test-to-Treat" Pad for Real-Time Visual Monitoring of Bacterial Infection and On-Site Performing Smart Therapy Strategies
    Zhao, Chenxi
    Li, Yanjian
    Zhao, Junjian
    Li, Hailong
    Xu, Jingwen
    Gao, Zhida
    Ding, Chen
    Song, Yan-Yan
    [J]. ACS NANO, 2023, 17 (14) : 13296 - 13309
  • [48] Development of an Improved Sulfur-Oxidizing Bacteria-Based Ecotoxicity Test for Simple and Rapid On-Site Application
    Eom, Heonseop
    [J]. TOXICS, 2023, 11 (04)
  • [49] On-site detection of nodavirus in post larval (PL) stage of the giant prawn, Macrobrachium rosenbergii: A test to nip the problem in the bud
    Jamalpure, Snehal
    Vimal, S.
    Ahmed, A. Nafeez
    Hameed, A. S. Sahul
    Paknikar, Kishore M.
    Rajwade, Jyutika M.
    [J]. AQUACULTURE, 2021, 534
  • [50] Study on Descriptors of Acoustic Emission Signals Generated by Partial Discharges under Laboratory Conditions and in On-Site Electrical Power Transformer
    Kunicki, Michal
    Cichon, Andrzej
    Borucki, Sebastian
    [J]. ARCHIVES OF ACOUSTICS, 2016, 41 (02) : 265 - 276