Development of an Improved Sulfur-Oxidizing Bacteria-Based Ecotoxicity Test for Simple and Rapid On-Site Application

被引:1
|
作者
Eom, Heonseop [1 ]
机构
[1] Keimyung Univ, Dept Civil Engn, 1095 Dalgubeol daero, Daegu 42601, South Korea
基金
新加坡国家研究基金会;
关键词
ecotoxicity; sulfur-oxidizing bacteria; electrical conductivity; TOXICITY ASSESSMENT; HEAVY-METALS; ACIDITHIOBACILLUS FERROOXIDANS; DIRECT-CONTACT; WASTE-WATER; BIOASSAY; BIOSENSOR; SOB; POLLUTANTS; OXIDATION;
D O I
10.3390/toxics11040352
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Microbial toxicity tests are considered efficient screening tools for the assessment of water contamination. The objective of this study was to develop a sulfur-oxidizing bacteria (SOB)-based ecotoxicity test with high sensitivity and reproducibility for simple and rapid on-site application. To attain this goal, we developed a 25 mL vial-based toxicity kit and improved our earlier SOB toxicity test technique. The current study applied a suspended form of SOB and shortened the processing time to 30 min. Moreover, we optimized the test conditions of the SOB toxicity kit in terms of initial cell density, incubating temperature, and mixing intensity during incubation. We determined that 2 x 10(5) cells/mL initial cell density, 32 degrees C incubating temperature, and 120 rpm mixing intensity are the optimal test conditions. Using these test conditions, we performed SOB toxicity tests for heavy metals and petrochemicals, and obtained better detection sensitivity and test reproducibility, compared to earlier SOB tests. Our SOB toxicity kit tests have numerous advantages, including a straightforward test protocol, no requirement of sophisticated laboratory equipment, and no distortion of test results from false readings of end-points and properties of test samples, making it suitable for simple and rapid on-site application.
引用
收藏
页数:11
相关论文
共 3 条
  • [1] Development of an accelerated test of biodeterioration of mortars involving a succession of sulfur-oxidizing bacteria
    Miokono, E. Hondjuila
    Lors, C.
    Lamberet, S.
    Damidot, D.
    [J]. MATERIAUX & TECHNIQUES, 2011, 99 (05): : 555 - 563
  • [2] Development of a colloidal gold-based immunochromatographic test strip for the rapid, on-site detection of Pseudomonas aeruginosa in clinical samples
    Wang, Yan
    Dou, Hengli
    Chen, Kuixiang
    Zhang, Hua
    Hu, Chengjin
    [J]. SCANDINAVIAN JOURNAL OF INFECTIOUS DISEASES, 2011, 43 (05) : 329 - 338
  • [3] Development of portable whole-cell biosensing platform with lyophilized bacteria and its application for rapid on-site detection of heavy metal toxicity without pre-resuscitation
    Wang, Hongliang
    Song, Dan
    Chen, Yuyang
    Xu, Wenjuan
    Han, Xiangzhi
    Zhu, Anna
    Long, Feng
    [J]. ANALYTICA CHIMICA ACTA, 2022, 1228