The Preclose Technique in Percutaneous Endovascular Aortic Repair: A Systematic Literature Review and Meta-analysis

被引:53
|
作者
Jaffan, Abdel Aziz A. [1 ]
Prince, Ethan A. [2 ]
Hampson, Christopher O. [3 ]
Murphy, Timothy P. [2 ]
机构
[1] Emory Univ, Sch Med, Dept Radiol, Div Intervent Radiol & Image Guided Med, Atlanta, GA 30322 USA
[2] Brown Univ, Rhode Isl Hosp, Warren Alpert Med Sch, Sect Vasc & Intervent Radiol,Dept Diagnost Imagin, Providence, RI 02903 USA
[3] Mercy Hosp, Oklahoma City, OK 73120 USA
关键词
Abdominal aortic aneurysms; Aneurysms; Arterial intervention; Endovascular aneurysm repair/endovascular aortic repair; Graft/endograft; Thoracic endovascular aortic repair; ARTERY ACCESS SITES; ANEURYSM REPAIR; STENT-GRAFT; FEMORAL-ARTERY; CLOSURE DEVICES; EXPERIENCE; OUTCOMES; COMPLICATIONS; PLACEMENT; PUNCTURE;
D O I
10.1007/s00270-013-0593-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To establish the efficacy and safety of the preclose technique in total percutaneous endovascular aortic repair (PEVAR). A systematic literature search of Medline database was conducted for series on PEVAR published between January 1999 and January 2012. Thirty-six articles comprising 2,257 patients and 3,606 arterial accesses were included. Anatomical criteria used to exclude patients from undergoing PEVAR were not uniform across all series. The technical success rate was 94 % per arterial access. Failure was unilateral in the majority (93 %) of the 133 failed PEVAR cases. The groin complication rate in PEVAR was 3.6 %; a minority (1.6 %) of these groin complications required open surgery. The groin complication rate in failed PEVAR cases converted to groin cutdown was 6.1 %. A significantly higher technical success rate was achieved when arterial access was performed via ultrasound guidance. Technical failure rate was significantly higher with larger sheath size (a parts per thousand yen20F). The preclose technique in PEVAR has a high technical success rate and a low groin complication rate. Technical success tends to increase with ultrasound-guided arterial access and decrease with larger access. When failure occurs, it is unilateral in the majority of cases, and conversion to surgical cutdown does not appear to increase the operative risk.
引用
收藏
页码:567 / 577
页数:11
相关论文
共 50 条
  • [1] The Preclose Technique in Percutaneous Endovascular Aortic Repair: A Systematic Literature Review and Meta-analysis
    Abdel Aziz A. Jaffan
    Ethan A. Prince
    Christopher O. Hampson
    Timothy P. Murphy
    [J]. CardioVascular and Interventional Radiology, 2013, 36 : 567 - 577
  • [2] Percutaneous access for endovascular aortic aneurysm repair: A systematic review and meta-analysis
    Hajibandeh, Shahin
    Hajibandeh, Shahab
    Antoniou, Stavros A.
    Child, Emma
    Torella, Francesco
    Antoniou, George A.
    [J]. VASCULAR, 2016, 24 (06) : 638 - 648
  • [3] Total percutaneous access for endovascular aortic aneurysm repair ("Preclose" technique)
    Lee, W. Anthony
    Brown, Michael P.
    Nelson, Peter R.
    Huber, Thomas S.
    [J]. JOURNAL OF VASCULAR SURGERY, 2007, 45 (06) : 1095 - 1101
  • [4] Midterm outcomes of femoral arteries after percutaneous endovascular aortic repair using the Preclose technique
    Lee, W. Anthony
    Brown, Michael P.
    Nelson, Peter R.
    Huber, Thomas S.
    Seeger, James M.
    [J]. JOURNAL OF VASCULAR SURGERY, 2008, 47 (05) : 919 - 923
  • [5] Endovascular repair of ruptured abdominal aortic aneurysms:: A systematic review and meta-analysis
    Mastracci, Tara M.
    Garrido-Olivares, Luis
    Cina, Claudio S.
    Chir, Spec
    Clase, Catherine M.
    [J]. JOURNAL OF VASCULAR SURGERY, 2008, 47 (01) : 214 - 221
  • [6] Reintervention after endovascular repair for aortic dissection: A systematic review and meta-analysis
    Zhang, Lei
    Zhao, Zhiqing
    Chen, Yanqing
    Sun, Yudong
    Bao, Junmin
    Jing, Zaiping
    Zhou, Jian
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 152 (05): : 1279 - +
  • [7] Endograft Anaconda in Endovascular Aneurysm Repair: A Systematic Review of Literature and Meta-Analysis
    Abatzis-Papadopoulos, Manolis
    Tigkiropoulos, Konstantinos
    Nikas, Spyridon
    Sidiropoulou, Katerina
    Alexou, Christina
    Kostopoulou, Olympia
    Stavridis, Kyriakos
    Karamanos, Dimitrios
    Lazaridis, Ioannis
    Saratzis, Nikolaos
    [J]. ANNALS OF VASCULAR SURGERY, 2024, 104 : 93 - 109
  • [8] Modifications in Aortic Stiffness After Endovascular or Open Aortic Repair: A Systematic Review and Meta-Analysis
    Bissacco, Daniele
    Conti, Michele
    Domanin, Maurizio
    Bianchi, Daniele
    Scudeller, Luigia
    Mandigers, Tim J.
    Allievi, Sara
    Auricchio, Ferdinando
    Trimarchi, Santi
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2022, 63 (04) : 567 - 577
  • [9] Diameter change of common femoral arteries after percutaneous endovascular aortic repair with the use of the preclose technique
    Lin, Yang-Yu
    Shie, Ren-Fu
    Liu, Kuo-Sheng
    Yu, Shang-Yueh
    Su, I-Hao
    Chen, Chien-Ming
    Lyu, Sin-Yi
    Ko, Po-Jen
    [J]. JOURNAL OF VASCULAR SURGERY, 2014, 60 (01) : 50 - 56
  • [10] Preclose technique for percutaneous endovascular therapy of abdominal and thoracic aortic aneurysms
    Schwindt, A.
    Donas, K.
    Torsello, G.
    [J]. GEFASSCHIRURGIE, 2011, 16 (03): : 182 - 186