Diameter change of common femoral arteries after percutaneous endovascular aortic repair with the use of the preclose technique

被引:5
|
作者
Lin, Yang-Yu [1 ,2 ]
Shie, Ren-Fu [1 ,2 ]
Liu, Kuo-Sheng [1 ,3 ]
Yu, Shang-Yueh [1 ,3 ]
Su, I-Hao [1 ,2 ]
Chen, Chien-Ming [1 ,2 ]
Lyu, Sin-Yi [1 ,2 ]
Ko, Po-Jen [1 ,3 ]
机构
[1] Chang Gung Univ, Taoyuan, Taiwan
[2] Chang Gung Mem Hosp, Dept Med Imaging & Intervent, Taoyuan 333, Taiwan
[3] Chang Gung Mem Hosp, Dept Thorac & Cardiovasc Surg, Taoyuan 333, Taiwan
关键词
ANEURYSM REPAIR; CLOSURE; ACCESS;
D O I
10.1016/j.jvs.2014.01.035
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: One of the major concerns regarding the preclose technique is its influence on the diameter of the accessed common femoral artery (CFA). The aim of our study was to evaluate the CFA diameter change after percutaneous endovascular aortic repair (PEVAR) with the use of the preclose technique. Methods: From February 2012 to September 2013, 192 patients who underwent PEVAR with the preclose technique were reviewed. The patients were followed postoperatively with computed tomographic angiography 1, 6, and 12 months after PEVAR, and only those with complete computed tomography studies were included. For each access site, the inner diameter (ID) and outer diameter (OD) of the CFA were measured, and the diameters at various time periods were compared. In addition, the patient cohort was divided into four subgroups according to two parameters: the sheath size (12-16F and 18-24F) and the number of closure devices used for the preclose technique (two devices, more than two devices). The differences in diameter change between the subgroups were analyzed. The significance of the diameter change and the influences of the two parameters were analyzed statistically with the use of the paired t-test, one-way analysis of variance, and two-way analysis of variance. Results: Fifty-eight patients fulfilled the study criteria. No significant influence on the ID of the accessed CFAs was observed at baseline and 1, 6, and 12 months (9.0 +/- 1.75 mm, 9.1 +/- 1.70 mm, 8.9 +/- 1.72 mm, and 9.0 +/- 1.68 mm, respectively). By contrast, a significant increase in initial OD occurred 1 month after PEVAR but gradually decreased in size in the following 11 months (13.0 +/- 2.37 mm, 16.4 +/- 3.44 mm, 14.2 +/- 3.06 mm, and 13.5 +/- 2.42 mm, respectively). Both the sheath size and the number of closure devices significantly affected the OD change (P <.001 and P =.037, respectively). The effect produced by the number of closure devices extended to 6 months after PEVAR, but the effect of the sheath size ceased before that time. Conclusions: This study demonstrates that PEVAR with the use of the preclose technique does not influence the ID of the accessed CFA, whereas the OD changes gradually over 1 year. These results may indicate that future endovascular interventions can be performed with the use of the same access without the risk of vascular narrowing.
引用
收藏
页码:50 / 56
页数:7
相关论文
共 50 条
  • [1] Midterm outcomes of femoral arteries after percutaneous endovascular aortic repair using the Preclose technique
    Lee, W. Anthony
    Brown, Michael P.
    Nelson, Peter R.
    Huber, Thomas S.
    Seeger, James M.
    [J]. JOURNAL OF VASCULAR SURGERY, 2008, 47 (05) : 919 - 923
  • [2] Total percutaneous access for endovascular aortic aneurysm repair ("Preclose" technique)
    Lee, W. Anthony
    Brown, Michael P.
    Nelson, Peter R.
    Huber, Thomas S.
    [J]. JOURNAL OF VASCULAR SURGERY, 2007, 45 (06) : 1095 - 1101
  • [3] The Preclose Technique in Percutaneous Endovascular Aortic Repair: A Systematic Literature Review and Meta-analysis
    Jaffan, Abdel Aziz A.
    Prince, Ethan A.
    Hampson, Christopher O.
    Murphy, Timothy P.
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 36 (03) : 567 - 577
  • [4] Comparison of Percutaneous Versus Open Repair of Femoral Arteries During Aortic Endovascular Aortic Repair
    Louis, Nicolas
    Desgranges, Pascal
    Allaire, Eric
    Kobeiter, Enchain
    Marzelle, Jean
    Becquemin, Jean-piere
    [J]. JOURNAL OF VASCULAR SURGERY, 2010, 51 : 93S - 93S
  • [5] The Preclose Technique in Percutaneous Endovascular Aortic Repair: A Systematic Literature Review and Meta-analysis
    Abdel Aziz A. Jaffan
    Ethan A. Prince
    Christopher O. Hampson
    Timothy P. Murphy
    [J]. CardioVascular and Interventional Radiology, 2013, 36 : 567 - 577
  • [6] Preclose technique for percutaneous endovascular therapy of abdominal and thoracic aortic aneurysms
    Schwindt, A.
    Donas, K.
    Torsello, G.
    [J]. GEFASSCHIRURGIE, 2011, 16 (03): : 182 - 186
  • [7] Comparison between PeRcutanEous and surgical femoral aCcess for endovascuLar aOrtic repair in patientS with typE III aortic Dissection (PRECLOSE Trial)
    Sahin, Ahmet A.
    Guner, Ahmet
    Demir, Ali R.
    Uzun, Nedim
    Onan, Burak
    Topel, Cagdas
    Celik, Omer
    [J]. VASCULAR, 2021, 29 (04) : 616 - 623
  • [8] Change in Aortic Neck Diameter after Endovascular Aortic Aneurysm Repair
    Kret, Marcus R.
    Tran, Kenneth
    Lee, Jason T.
    [J]. ANNALS OF VASCULAR SURGERY, 2017, 43 : 115 - 120
  • [9] Superficial Femoral Artery Use for Percutaneous Endovascular Aortic Aneurysm Repair
    Faizer, Rumi
    Aaron, Ashley
    Trieu, Huy
    Levin, Steve
    Messelt, Andrew
    Rosenberg, Michael
    Santilli, Steve
    [J]. JOURNAL OF VASCULAR SURGERY, 2014, 60 (04) : 1099 - 1100
  • [10] Rate of change in abdominal aortic aneurysm diameter after endovascular repair
    Wolf, YG
    Hill, BB
    Rubin, GD
    Fogarty, TJ
    Zarins, CK
    [J]. JOURNAL OF VASCULAR SURGERY, 2000, 32 (01) : 108 - 113