Optimization of X-ray image acquisition and reconstruction for a C-arm CBCT system with a flat-panel detector

被引:2
|
作者
Cha, Bo Kyung [1 ]
Jeon, Seongchae [1 ]
Seo, Chang-Woo [2 ]
Back, Jongduck [3 ]
Choi, Shinkook [3 ]
Lee, Changwoo [3 ]
Ahn, Miseob [4 ]
机构
[1] Korea Electrotechnol Res Inst, Adv Med Device Res Ctr, Ansan, South Korea
[2] Yonsei Univ, Dept Radiol Sci, Wonju 220710, Gangwon Do, South Korea
[3] Yonsei Univ, Converged Sch Integrated Technol, Incheon, South Korea
[4] Samsung Med Ctr, Dept Diagnost Imaging, Seoul, South Korea
关键词
Flat-panel X-ray detector; C-arm CT system; Cone-beam CT system; 3D image reconstruction; CONE-BEAM CT; ANTISCATTER GRIDS;
D O I
10.1016/j.nima.2018.12.065
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A modern cone-beam computed tomography (CBCT) system with a C-arm gantry incorporating a large-area flat-panel detector is an important imaging tool widely used for diagnosis and image-guidance in spine surgery, orthopedic and interventional suite, and image-guided radiation therapy. In this study, the experimental prototype CBCT imaging platform consists of a benchtop system that is integrated with a cone-beam X-ray tube, a collimator, an anti-scatter grid, and a large-area TFT-based flat-panel detector. The different projection images in the C-arm CT system were usually acquired at short scanning angles with a constant interval for various exposure conditions. The performance of CT imaging quality was performed using the Feldkamp, Davis and Kress (FDK) reconstruction algorithm through acquired two-dimensional projection images at different scanning angles and projection numbers. Quantitative analysis of the image quality was performed by using the cone-beam CT phantom for spatial resolution, low-contrast resolution, noise, and two different phantoms, such as the head and pelvis.
引用
收藏
页码:343 / 349
页数:7
相关论文
共 50 条
  • [31] Experimental evaluation of a-Se flat-panel X-ray detector for digital radiography
    Choi, JY
    Park, JK
    Lee, DG
    Kang, SS
    Nam, SH
    [J]. NEW APPLICATIONS FOR WIDE-BANDGAP SEMICONDUCTORS, 2003, 764 : 265 - 270
  • [32] Dual-energy cardiac imaging: an image quality and dose comparison for a flat-panel detector and x-ray image intensifier
    Ducote, Justin L.
    Xu, Tong
    Molloi, Sabee
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (01): : 183 - 196
  • [33] Change your Angle of ViewSinusoidal C-Arm Movement in Cranial Flat-panel CT to Improve Image Quality
    Hannes Luecking
    Philip Hoelter
    Stefan Lang
    Manuel Schmidt
    Felix Eisenhut
    Arnd Doerfler
    [J]. Clinical Neuroradiology, 2022, 32 : 1109 - 1115
  • [34] Flat-panel cone-beam CT on a mobile isocentric C-arm for image-guided brachytherapy
    Jaffray, DA
    Siewerdsen, JH
    Edmundson, G
    Wong, J
    Martinez, A
    [J]. MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 209 - 217
  • [35] Digital radiography system with a full-size, flat-panel X-ray detector: Evaluation of imaging performance
    Neitzel, U
    Maack, I
    Rindt, K
    Spiess, K
    [J]. RADIOLOGY, 1998, 209P : 161 - 161
  • [36] Digital radiography with a large-area, amorphous-silicon, flat-panel X-ray detector system
    Spahn, M
    Strotzer, M
    Völk, M
    Böhm, S
    Geiger, B
    Hahm, G
    Feuerbach, S
    [J]. INVESTIGATIVE RADIOLOGY, 2000, 35 (04) : 260 - 266
  • [37] Development of an Integrated C-Arm Interventional Imaging System With a Strip Photon Counting Detector and a Flat Panel Detector
    Ji, Xu
    Feng, Mang
    Treb, Kevin
    Zhang, Ran
    Schafer, Sebastian
    Li, Ke
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (12) : 3674 - 3685
  • [38] Modeling and optimization of rotational C-arm stereoscopic X-ray angiography
    Talukdar, AS
    Wilson, DL
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (07) : 604 - 616
  • [39] Distortion Correction, Geometric Calibration, and Volume Reconstruction for an Isocentric C-Arm X-Ray System
    Mennessier, C.
    Spencer, B.
    Clackdoyle, R.
    Conneau, A-C.
    Xu, T.
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2943 - 2947
  • [40] ECG-Gated CT Reconstruction for a C-Arm Inverse Geometry X-Ray System
    Slagowski, J. M.
    Dunkerley, D. A. P.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3701 - 3701