Cooling System Design for Data Centers Utilizing Containment Architecture

被引:0
|
作者
Wilson, Davis
机构
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The unique features and design requirements of Data Centers utilizing hot or cold aisle containment will be described with a focus on their impact on system design. These include determining the proper temperature and humidity levels entering the unit, humidification and dehumidification, calculating unit airflow, and unique control schemes. With traditional architectures, the temperature and humidity of the air entering the cooling equipment is typically assumed to be equal to that of the air in the space. With containment the temperature and humidity of the air leaving the cooling equipment, the air entering the servers, and the air returning to the cooling equipment must be considered separately. Due to the high temperature of the air entering the cooling equipment the cooling coil is often hot and dry prohibiting the unit from dehumidifying the space. In these cases dehumidification must be done by equipment other than the primary cooling units. Humidification can still be done with the cooling units but care must be taken in the humidity measurement. Determining the unit airflow is also a challenge. Since most of the airflow passes through the servers, unit airflow must be closely matched to the cumulative server airflow. The unit controller must determine the server airflow, or use a proxy, and vary the unit airflow accordingly. Special consideration must also be given to control of the cooling source and in the use of DX equipment.
引用
收藏
页码:415 / 419
页数:5
相关论文
共 50 条
  • [1] MODELING AND CONTROL FOR COOLING MANAGEMENT OF DATA CENTERS WITH HOT AISLE CONTAINMENT
    Zhou, Rongliang
    Wang, Zhikui
    Bash, Cullen E.
    McReynolds, Alan
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 4, PTS A AND B, 2012, : 739 - 746
  • [2] Study on the Performance of a Newly Designed Cooling System Utilizing Dam Water for Internet Data Centers
    Anka, Selorm Kwaku
    Boafo, Nicholas Lamptey
    Mensah, Kwesi
    Boahen, Samuel
    Lee, Kwang Ho
    Choi, Jong Min
    [J]. ENERGIES, 2022, 15 (24)
  • [3] Cooling Performance of Ceiling-Plenum-Ducted Containment Systems in Data Centers
    VanGilder, James W.
    Zhang, Xuanhang
    [J]. 2014 IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM), 2014, : 786 - 792
  • [4] A novel approach to the data center hybrid cooling design with containment
    Fouladi, Kamran
    Schaadt, Joseph
    Wemhoff, Aaron P.
    [J]. NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2017, 71 (05) : 477 - 487
  • [5] Optimal design of passive containment cooling system for innovative PWR
    Ha, Huiun
    Lee, Sangwon
    Kim, Hangon
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2017, 49 (05) : 941 - 952
  • [6] Design of water distribution device for passive containment cooling system
    Zhang, Ting-Xiang
    Tang, Yu
    [J]. Hedongli Gongcheng/Nuclear Power Engineering, 2002, 23 (SUPPL.): : 103 - 106
  • [7] Conceptual design and analysis of a semi-passive containment cooling system for a large concrete containment
    Byun, CS
    Jerng, DW
    Todreas, NE
    Driscoll, MJ
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2000, 199 (03) : 227 - 242
  • [8] Development of a Cooling Control System For Data Centers Utilizing Indirect Fresh Air Based on Model Predictive Control
    Ogawa, Masatoshi
    Fukuda, Hiroyuki
    Kodama, Hiroyoshi
    Endo, Hiroshi
    Sugimoto, Toshio
    Kasajima, Takeo
    Kondo, Masao
    [J]. 2015 7th International Congress on Ultra Modern Telecommunications and Control Systems and Workshops (ICUMT), 2015, : 132 - 137
  • [9] Modelling and control of a free cooling system for Data Centers
    Beghi, Alessandro
    Cecchinato, Luca
    Dalla Mana, Giuseppe
    Lionello, Michele
    Rampazzo, Mirco
    Sisti, Enrico
    [J]. BEYOND NZEB BUILDINGS, 2017, 140 : 447 - 457
  • [10] Improving data centers with AISLE containment
    [J]. Kennedy, D., 1600, Business News Publishing Co. (29):