A novel approach to the data center hybrid cooling design with containment

被引:5
|
作者
Fouladi, Kamran [1 ]
Schaadt, Joseph [2 ]
Wemhoff, Aaron P. [2 ]
机构
[1] Widener Univ, Dept Mech Engn, 1 Univ Pl, Chester, PA 19013 USA
[2] Villanova Univ, Dept Mech Engn, Villanova, PA 19085 USA
基金
美国国家科学基金会;
关键词
D O I
10.1080/10407782.2016.1277932
中图分类号
O414.1 [热力学];
学科分类号
摘要
Hybrid cooling solutions, which consist of the installation of heat exchangers near IT equipment, aim to eliminate hot spots in data centers containing high-density computer cabinets. In addition, cold aisle containment is often used to reduce hot air recirculation to improve energy efficiency. However, the viability and efficiency of each hybrid cooling strategy with or without containment depend on the IT load and equipment arrangement, and no formal procedure exists for selecting the most efficient strategy for a given application. Therefore, this study provides a computational approach for ranking the performance of different cooling strategies based on their capacity and cooling efficiency. The results of analyses indicate that applying containment is beneficial in (1) lowering the maximum temperature of the air entering the racks as airflow rates are increased, and (2) increasing the uniformity of rack inlet temperatures. However, applying containment also requires additional mechanical work by the computer room air handler (CRAH) fan, which may raise the data center power usage effectiveness (PUE). Application of the computational approach discussed here highlights the use of hybrid cooling to lower PUE by reducing the CRAH fan power.
引用
收藏
页码:477 / 487
页数:11
相关论文
共 50 条
  • [1] Cooling System Design for Data Centers Utilizing Containment Architecture
    Wilson, Davis
    [J]. ASHRAE TRANSACTIONS 2012, VOL 118, PT 1, 2012, 118 : 415 - 419
  • [2] AN INVESTIGATION INTO COOLING SYSTEM CONTROL STRATEGIES FOR DATA CENTER AIRFLOW CONTAINMENT ARCHITECTURES
    Patterson, Michael K.
    Weidmann, Rainer
    Leberecht, Markus
    Mair, Manuel
    Libby, Richard M.
    [J]. PROCEEDINGS OF THE ASME PACIFIC RIM TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC SYSTEMS, MEMS AND NEMS 2011, VOL 2, 2012, : 479 - +
  • [3] A Novel Joint Routing and Channel Allocation Approach in Hybrid Data Center Network
    Dab, Boutheina
    Fajjari, Ilhem
    Aitsaadi, Nadjib
    [J]. 2017 14TH ANNUAL IEEE INTERNATIONAL CONFERENCE ON SENSING, COMMUNICATION, AND NETWORKING (SECON), 2017, : 163 - 171
  • [4] Experimental investigation on ducted hot aisle containment system for racks cooling of data center
    Zhan, Binfei
    Shao, Shuangquan
    Lin, Mi
    Zhang, Hainan
    Tian, Changqing
    Zhou, Yuan
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 127 : 137 - 147
  • [5] NUMERICAL MODELING APPROACH TO DYNAMIC DATA CENTER COOLING
    Ibrahim, Mahmoud
    Gondipalli, Srujan
    Bhopte, Siddharth
    Sammakia, Bahgat
    Murray, Bruce
    Ghose, Kanad
    Iyengar, Madhusudan K.
    Schmidt, Roger
    [J]. 2010 12TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, 2010,
  • [6] A Holistic and Optimal Approach for Data Center Cooling Management
    Zhou, Rongliang
    Wang, Zhikui
    Bash, Cullen E.
    McReynolds, Alan
    Hoover, Christopher
    Shih, Rocky
    Kumari, Niru
    Sharma, Ratnesh K.
    [J]. 2011 AMERICAN CONTROL CONFERENCE, 2011, : 1346 - 1351
  • [7] Study of Air Flow Energy within Data Center Room and Sizing of Hot Aisle Containment for an Active vs Passive Cooling Design
    Sahini, Manasa
    Kumar, Eric
    Gao, Tianyi
    Ingalz, Charles
    Heydari, Ali
    Sun Xiaogang
    [J]. 2016 15TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM), 2016, : 1453 - 1457
  • [8] Containment passive-cooling design concepts
    Univ of Maryland, College Park, United States
    [J]. Prog Nucl Energy, 3-4 (647-655):
  • [9] Containment passive-cooling design concepts
    Gavrilas, M
    Todreas, NE
    Driscoll, MJ
    [J]. PROGRESS IN NUCLEAR ENERGY, 1998, 32 (3-4) : 647 - 655
  • [10] Cooling the Data Center
    Woods, Andy
    [J]. COMMUNICATIONS OF THE ACM, 2010, 53 (04) : 36 - 42