MODELING AND CONTROL FOR COOLING MANAGEMENT OF DATA CENTERS WITH HOT AISLE CONTAINMENT

被引:0
|
作者
Zhou, Rongliang [1 ]
Wang, Zhikui [1 ]
Bash, Cullen E. [1 ]
McReynolds, Alan [1 ]
机构
[1] Hewlett Packard Corp, HP Labs, Sustainable Ecosyst Res Grp, Palo Alto, CA 94304 USA
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
In traditional raised-floor data center design with hot aisle and cold aisle separation, the cooling efficiency suffers from recirculation resulting from the mixing of cool air from the Computer Room Air Conditioning (CRAG) units and the hot exhaust air exiting from the back of the server racks. To minimize recirculation and hence increase cooling efficiency, hot aisle containment has been employed in an increasing number of data centers. Based on the underlying heat transfer principles, we present in this paper a dynamic model for cooling management in both open and contained environment, and propose decentralized model predictive controllers (MPC) for control of the CRAC units. One approach to partition a data center into overlapping CRAC zones of influence is discussed. Within each zone, the CRAC unit blower speed and supply air temperature are adjusted by a MPC controller to regulate the rack inlet temperatures, while minimizing the cooling power consumption. The proposed decentralized cooling control approach is validated in a production data center with hot aisles contained by plastic strips. Experimental results demonstrate both its stability and ability to reject various disturbances.
引用
收藏
页码:739 / 746
页数:8
相关论文
共 50 条
  • [1] Analysis of Air Leakage from Hot Aisle Containment Systems and Cooling Efficiency of Data Centers
    Khankari, Kishor
    [J]. ASHRAE TRANSACTIONS 2014, VOL 120, PT 1, 2014, 120
  • [2] Balancing Cooling and IT Airflow with Dampers in Ceiling-Ducted Hot-Aisle Containment in Data Centers
    VanGilder, James
    Zhang, Yan
    Linder, Stephen
    Condor, Michael
    [J]. PROCEEDINGS OF THE 2019 EIGHTEENTH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM 2019), 2019, : 1282 - 1288
  • [3] Improving data centers with AISLE containment
    [J]. Kennedy, D., 1600, Business News Publishing Co. (29):
  • [4] Experimental investigation on ducted hot aisle containment system for racks cooling of data center
    Zhan, Binfei
    Shao, Shuangquan
    Lin, Mi
    Zhang, Hainan
    Tian, Changqing
    Zhou, Yuan
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 127 : 137 - 147
  • [5] Experimental Characterization of Cold Aisle Containment for Data Centers
    Sundaralingam, Vikneshan
    Arghode, Vaibhav K.
    Joshi, Yogendra
    [J]. 2013 TWENTY NINTH ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM (SEMI-THERM), 2013, : 223 - 230
  • [6] ENERGY SAVINGS THROUGH HOT AND COLD AISLE CONTAINMENT CONFIGURATIONS FOR AIR COOLED SERVERS IN DATA CENTERS
    Schmidt, Roger
    Vallury, Aparna
    Iyengar, Madhusudan
    [J]. PROCEEDINGS OF THE ASME PACIFIC RIM TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC SYSTEMS, MEMS AND NEMS 2011, VOL 2, 2012, : 611 - +
  • [7] Experimental Characterization of Various Cold Aisle Containment Configurations for Data Centers
    Sundaralingam, Vikneshan
    Arghode, Vaibhav K.
    Joshi, Yogendra
    Phelps, Wally
    [J]. JOURNAL OF ELECTRONIC PACKAGING, 2015, 137 (01)
  • [8] A Comparative CFD Study of Two Air Distribution Systems with Hot Aisle Containment in High-Density Data Centers
    Cho, Jinkyun
    Woo, Jesang
    Park, Beungyong
    Lim, Taesub
    [J]. ENERGIES, 2020, 13 (22)
  • [9] Cold Aisle or Hot Aisle Containment - Is one better than the other?
    Sullivan, Robert
    Li, Guoqiang
    Zhang, Xiaofei
    [J]. 2018 IEEE INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE (INTELEC), 2018,
  • [10] An Experimental Analysis of Hot Aisle Containment Systems
    Khalili, Sadegh
    Alissa, Husam
    Desu, Anuroop
    Sammakia, Bahgat
    Ghose, Kanad
    [J]. PROCEEDINGS OF THE 17TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM 2018), 2018, : 748 - 760