Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA T, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V(100)(Prostate) > 90%) and organ-at-risk dose sparing (V(75)(Bladder) < 1 cc, V(75)(Rectum) < 1 cc, V(125)(Urethra) << 1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter patterns may decrease toxicity by avoidance of the critical structures near the penile bulb while still fulfilling the RTOG criteria. (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3041166]
引用
收藏
页码:233 / 239
页数:7
相关论文
共 50 条
  • [31] Dosimetric perturbations of a lead shield placed on the body surface for HDR brachytherapy
    Candela-Juan, C.
    Granero, D.
    Vijande, J.
    Ballester, F.
    Perez-Calatayud, J.
    Rivard, M. J.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S329 - S330
  • [32] Dosimetric Comparison of LDR Vs. HDR Tandem Ovoid Brachytherapy
    Li, W.
    Liu, L.
    Tanny, S.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [33] HDR prostate brachytherapy database: preliminary dosimetric and radiobiological analysis.
    Balabanova, A.
    Genova, B.
    Stavrev, P.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127
  • [34] A Dosimetric Study of the MicroSelectron HDR Ir-192 Brachytherapy Source
    Granero, D.
    Rivard, M. J.
    Ballester, F.
    Perez-Calatayud, J.
    Vijande, J.
    Otal, A.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [35] Superficial HDR brachytherapy - dosimetric verification of dose distribution with lead shielding
    Bieleda, G.
    Zwierzchowski, G.
    Szymbor, A.
    Boehlke, M.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S409 - S410
  • [36] Monte Carlo simulation of HDR Brachytherapy dosimetric parameters in different mediums
    Shukor, Nor Shazleen Ab
    Musarudin, Marianie
    Abdullah, Reduan
    Aziz, Mohd Zahri Abd
    RADIATION PHYSICS AND CHEMISTRY, 2022, 200
  • [37] Dosimetric Study of Surface Applicators of HDR Brachytherapy GammaMed Plus Equipment
    Reyes-Rivera, E.
    Sosa, M.
    Reyes, U.
    Monzon, E.
    Bernal, J.
    Cordova, T.
    Gil-Villegas, A.
    XIII MEXICAN SYMPOSIUM ON MEDICAL PHYSICS, 2014, 1626 : 181 - 184
  • [38] Simulation-Based Assessment of Dosimetric Uncertainty Due to Catheter Reconstruction Error in TRUS-Guided Prostate HDR Brachytherapy
    Dekker, K.
    Joshi, C.
    Kerr, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E848 - E849
  • [39] Catheter reconstruction and dosimetric verification of MRI-only treatment planning (MRTP) for interstitial HDR brachytherapy using PETRA sequence
    Lee, Casey Y.
    Kaza, Evangelia
    Harris, Thomas C.
    O'Farrell, Desmond A.
    King, Martin T.
    Dyer, Michael A.
    Cormack, Robert A.
    Buzurovic, Ivan
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (03):
  • [40] Curvilinear catheter implantation in HDR prostate brachytherapy: feasibility study
    Padasdao, Blayton
    Imanaka, Rex
    Podder, Tarun K.
    Konh, Bardia
    MEDICAL PHYSICS, 2024, 51 (09) : 6332 - 6347