EPID Dosimetry - Configuration and Pre-Treatment IMRT Verification

被引:0
|
作者
Grzadziel, A. [1 ]
Smolinska, B. [1 ]
Rutkowski, R. [1 ]
Slosarek, K. [1 ]
机构
[1] Ctr Oncol, MSC Mem Inst, Branch Gliwice, Radiotherapy & Brachytherapy Planning Dept, Gliwice, Poland
关键词
IMRT; aSI EPID; treatment plan verification; QA;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Electronic Portal Imaging Device (EPID) is used for patient setup during radiotherapy sessions. Dosimetric verification is done using the ion chambers, diodes and thermoluminescence detectors. In Intensity Modulated Radiation Therapy (IMRT) the dosimetry is sophisticated and time consuming task. The simultaneous use of an amorphous silicon (aSi) detectors and Transit Dosimetry (TD) option in Treatment Planning System (TPS) Eclipse, Varian enables dosimetric pre-treatment verification of the IMRT plans. The purpose of this study was to calibrate the EPID and TPS and to evaluate the usefulness of that method for dose verification in IMRT technique. First step was calibration of the aSi EPID mounted on three linear accelerators Clianc23EXS, Varian. Afterwards, configuration of the calculation algorithm in TPS was carried out. Then dosimetric characteristics of the EPID were investigated. The EPID response depending on the beam mode, treatment time and static square field size was measured. The same measurements were repeated twice for three accelerators and analyzed. Furthermore, three IMRT plans were treated for the pretreatment dose evaluation. The calculated dose matrix was compared with delivered one. The similarity of the calculated and measured fluency maps were evaluated by means of gamma index in Eclipse. The linearity of the EPID signal was proven. For both beam modes EPIDs response is proportional to treatment time and field size, within the considered field size range. However, the obtained results can slightly differ for the different accelerators that are equipped with different imaging devices. The gamma evaluation indicates good correlation between predicted and acquired EPID image. Although some differences in a high gradient area were found. We found EPID based pre-treatment IMRT verification method as a good Quality Assurance (QA) procedure. Quite frequent control of the method and the periodic recalibration of the used device are required.
引用
收藏
页码:1932 / 1936
页数:5
相关论文
共 50 条
  • [11] 3D EPID based dosimetry for pre-treatment verification of VMAT - methods and challenges
    Greer, P. B.
    [J]. 7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [12] Comparison of the Efficacy of 2D Dosimetry Systems in the Pre-treatment Verification of IMRT
    Hong, Chae Seon
    Lim, Jongsoo
    Ju, Sang Gyu
    Shin, Eunhyuk
    Han, Youngyih
    Ahn, Yong Chan
    [J]. RADIATION ONCOLOGY JOURNAL, 2009, 27 (02): : 91 - 102
  • [13] Patient Specific IMRT Pre-Treatment Verification Using A Commercial Portal Dosimetry Software
    Varatharaj, C.
    Moretti, E.
    Manickam, R.
    Padovani, R.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3788 - 3788
  • [14] Validation Of Elekta Iviewgt A-Si Epid Model For Pre-Treatment Dose Verification Of Imrt Fields
    Herwiningsih, Sri
    Fielding, Andrew
    [J]. 4TH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTER THEORY AND ENGINEERING ( ICACTE 2011), 2011, : 35 - 38
  • [15] Pre-treatment verification of clinical IMRT fields
    Ercan, T.
    Igdem, S.
    Yildirim, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S377 - S378
  • [16] Pre-treatment and in vivo EPID dosimetry for head and neck cancer
    McDermott, L.
    Wendling, M.
    Sonke, J.
    van Herk, M.
    Mijnheer, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S307 - S307
  • [17] Using EPID pre-treatment dosimetry to solve a clinical problem
    McDermott, LN
    Wendling, M
    Stroom, J
    van Asselen, B
    van Herk, M
    Mijnheer, BJ
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S65 - S66
  • [18] IMRT pre-treatment verification with ionization chamber, film and EPID: Quality vs. time consumption
    Starmans, M
    Dekker, A
    Nijsten, S
    Minken, A
    Lambin, P
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1984 - 1984
  • [19] IN VIVO DOSIMETRY AS SUBSTITUTE FOR PRE-TREATMENT VERIFICATION
    Mijnheer, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S191 - S191
  • [20] Pre-treatment verification of the patient dose with an amorphous silicon EPID
    Wendling, M
    McDermott, LN
    Louwe, RJW
    van Herk, MB
    Mijnheer, B
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S113 - S114