Effect of improper scan alignment on retinal nerve fiber layer thickness measurements using Stratus optical coherence tomograph

被引:54
|
作者
Vizzeri, Gianmarco [1 ]
Bowd, Christopher [1 ]
Medeiros, Felipe A. [1 ]
Weinreb, Robert N. [1 ]
Zangwill, Linda M. [1 ]
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
关键词
imaging; stratus optical coherence tomography; retinal nerve fiber layer thickness; reproducibility;
D O I
10.1097/IJG.0b013e31815c3aeb
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: Misalignment of the Stratus optical coherence tomograph scan circle placed by the operator around the optic nerve head (ONH) during each retinal nerve fiber layer (RNFL) examination can affect the instrument reproducibility and its theoretical ability to detect true structural changes in the RNFL thickness over time. We evaluated the effect of scan circle placement on RNFL measurements. Design: Observational clinical study. Methods: Sixteen eyes of 8 normal participants were examined using the Stratus optical coherence tomograph Fast RNFL thickness acquisition protocol (software version 4.0.7; Carl Zeiss Meditec, Dublin, CA). Four consecutive images were taken by the same operator with the circular scan centered oil the optic nerve head. Four images each with the scan displaced superiorly, inferiorly, temporally, and nasally were also acquired. Differences in average and sectoral RNFL thicknesses were determined. For the centered scans, the coefficients of variation (CV) and the intraclass correlation coefficient for the average RNFL thickness measured were calculated. Results: When the average RNFL thickness of the centered scans was compared with the average RNFL thickness of the displaced scans individually using analysis of variance with post-hoc analysis, no difference was found between the average RNFL thickness of the nasally (105.2 mu m), superiorly (106.2 mu m), or inferiorly (104.1 mu m) displaced scans and the centered scans (106.4 mu m). However, a significant difference (analysis of variance with Dunnett's test: F = 8.82, P < 0.0001) was found between temporally displaced scans (115.8 mu m) and centered scans. Significant differences in sectoral RNFL thickness measurements were found between centered and each displaced scan. The coefficient of variation for average RNFL thickness was 1.75% and intraclass correlation coefficient was 0.95. Conclusions: In normal eyes, average RNFL thickness measurement are robust and similar with significant superior, inferior. and nasal scan displacement, but average RNFL thickness is greater when scans are displaced temporally. Parapapillary scan misalignment produces significant changes in RNFL assessment characterized by an increase in measured RNFL thickness in the quadrant in which the scan is closer to the disc, and a significant decrease in RNFL thickness in the quadrant in which the scan is displaced further from the optic disc.
引用
下载
收藏
页码:341 / 349
页数:9
相关论文
共 50 条
  • [1] Effect of Signal Strength and Improper Alignment on the Variability of Stratus Optical Coherence Tomography Retinal Nerve Fiber Layer Thickness Measurements
    Vizzeri, Gianmarco
    Bowd, Christopher
    Medeiros, Felipe A.
    Weinreb, Robert N.
    Zangwill, Linda M.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (02) : 249 - 255
  • [2] The effect of scan diameter on retinal nerve fiber layer thickness measurement using stratus optic coherence tomography
    Savini, Giacomo
    Barboni, Piero
    Carbonelli, Michele
    Zanini, Maurizio
    ARCHIVES OF OPHTHALMOLOGY, 2007, 125 (07) : 901 - 905
  • [3] Response to Comment on the Article Entitled "Effect of Improper Scan Alignment on Retinal Nerve Fiber Layer Thickness Measurements Using Stratus Optical Coherence Tomograph'' by Vizzeri G, et al Published in J Glaucoma. 2008; 17:341-349
    Vizzeri, Gianmarco
    Bowd, Christopher
    Medeiros, Felipe A.
    Weinreb, Robert N.
    Zangwill, Linda M.
    JOURNAL OF GLAUCOMA, 2015, 24 (04) : 334 - 334
  • [4] Comparison of Retinal Nerve Fiber Layer Thickness Values Using Stratus Optical Coherence Tomography and Heidelberg Retina Tomograph-III
    Moreno-Montanes, Javier
    Anton, Alfonso
    Garcia, Noelia
    Olmo, Natalia
    Morilla, Antonio
    Fallon, Monica
    JOURNAL OF GLAUCOMA, 2009, 18 (07) : 528 - 534
  • [5] Reproducibility of RTVue Retinal Nerve Fiber Layer Thickness and Optic Disc Measurements and Agreement with Stratus Optical Coherence Tomography Measurements
    Gonzalez-Garcia, Alberto O.
    Vizzeri, Gianmarco
    Bowd, Christopher
    Medeiros, Felipe A.
    Zangwill, Linda M.
    Weinreb, Robert N.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (06) : 1067 - 1074
  • [6] Comment on the Article Entitled "Effect of Improper Scan Alignment on Retinal Nerve Fiber Layer Thickness Measurements Using Stratus Optical Coherence Tomograph" by Vizzeri G, Bowd C, Medeiros F, Weinreb R, Zangwill L, Published in J Glaucoma. 2008;17:341-349
    Yoo, Chungkwon
    Suh, Il Hoon
    Kim, Yong Yeon
    JOURNAL OF GLAUCOMA, 2010, 19 (03) : 226 - 227
  • [7] Effect of pupillary dilation on retinal nerve fiber layer thickness measurements using optical coherence tomography
    Zafar, S
    Gurses-Ozden, R
    Vessani, R
    Makornwattana, M
    Liebmann, JM
    Tello, C
    Ritch, R
    JOURNAL OF GLAUCOMA, 2004, 13 (01) : 34 - 37
  • [8] Macular and retinal nerve fiber layer thickness in Japanese measured by Stratus optical coherence tomography
    Oshitari, Toshiyuki
    Hanawa, Katsuhiro
    Adachi-Usami, Emiko
    CLINICAL OPHTHALMOLOGY, 2007, 1 (02): : 133 - 140
  • [9] Analysis of retinal nerve fiber layer and macular thickness measurements in healthy Taiwanese individuals using optical coherence tomography (Stratus OCT)
    Hsu, Sheng-Yao
    Tsai, Rong-Kung
    JOURNAL OF GLAUCOMA, 2008, 17 (01) : 30 - 35
  • [10] Accuracy of the Retinal Nerve Fiber Layer Measurements by Stratus Optical Coherence Tomography for Perimetric Glaucoma
    Gondal, Talat Mehmood
    Qazi, Zaheer Uddin Aqil
    Jamil, Ahmad Zeeshan
    Jamil, Muhammad Hannan
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2011, 21 (12): : 749 - 752