Accuracy and user performance evaluation of the Contour® Next Link 2.4 blood glucose monitoring system

被引:10
|
作者
Bailey, Timothy [1 ]
Wallace, Jane F. [2 ]
Greene, Carmine [2 ]
Pardo, Scott [2 ]
Brown, Daniel [2 ]
Pflug, Brian [2 ]
Klaff, Leslie J. [3 ]
机构
[1] AMCR Inst Inc, Escondido, CA 92025 USA
[2] Bayer HealthCare LLC, Diabet Care, Whippany, NJ 07981 USA
[3] Rainier Clin Res Ctr, Renton, WA 98057 USA
关键词
Self-monitoring of blood glucose; Type; 1; diabetes; 2; INSULIN; THERAPY;
D O I
10.1016/j.cca.2015.06.001
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The Contour (R) Next Link 2.4 blood glucose monitoring system (BGMS), which communicates wirelessly exclusively with a Medtronic insulin pump, was assessed in 2 separate studies. Methods: In the laboratory study (N = 100), subject capillary fingertip samples were tested in duplicate using 3 test strip lots; accuracy was assessed based on ISO 15197:2013 section 63 accuracy criteria (95% within +/- 15 mg/dl or +/- 15% of reference for glucose <100 and >= 100 mg/dl, respectively). In the clinical trial (N = 219), untrained subjects with diabetes tested capillary fingertip and palm blood samples and completed an ease-of-use questionnaire. BGMS and YSI glucose analyzer results were compared based on ISO 15197:2013 section 8 accuracy criteria. Results: In the laboratory study, 100% of results met ISO 15197:2013 section 6.3 accuracy criteria. In the clinical trial, 98.6% of capillary fingertip and 972% of palm results from subjects met ISO 15197:2013 section 8 accuracy criteria. By Parkes-Consensus Error Grid analysis, 100% of subject capillary fingertip results were within Zone A. Based on questionnaire results, the majority of subjects found the BGMS easy to use. Conclusions: The BGMS exceeds ISO 15197:2013 section 63 and section 8 accuracy criteria in the laboratory and in the hands of untrained users with diabetes. (C) 2015 The Authors. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:139 / 145
页数:7
相关论文
共 50 条
  • [21] System Accuracy Evaluation of a Blood Glucose Monitoring System
    Kenning, Matthes
    Puchert, Anselm
    Salzsieder, Eckhard
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (02): : 574 - 575
  • [22] Performance evaluation of Bayer Asencsia®-Contour® portable blood glucose monitoring system.
    Haliassos, A.
    Drakopoulos, I.
    Feskou, E.
    Rambaouni-Antonelli, A.
    Spanou, L.
    Panagiotopoulos, C.
    Makris, K.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A217 - A217
  • [23] CONTOUR® Blood Glucose Monitoring System (BGMS) Interference Evaluation
    Harrison, Bern
    Glasgow, David
    Tudor, Brenda
    Wang, Yuan
    Petruschke, Thorsten
    Schachner, Holly C.
    Halldorsdottir, Solveig
    DIABETES, 2010, 59 : A543 - A543
  • [24] Accuracy Evaluation of CONTOUR®PLUS Compared With Four Blood Glucose Monitoring Systems
    Dunne, Nancy
    Viggiani, Maria T.
    Pardo, Scott
    Robinson, Cynthia
    Parkes, Joan Lee
    DIABETES THERAPY, 2015, 6 (03) : 377 - 388
  • [25] Accuracy Evaluation of CONTOUR®PLUS Compared With Four Blood Glucose Monitoring Systems
    Nancy Dunne
    Maria T. Viggiani
    Scott Pardo
    Cynthia Robinson
    Joan Lee Parkes
    Diabetes Therapy, 2015, 6 : 377 - 388
  • [26] User Performance Evaluation and System Accuracy Assessment of Four Blood Glucose Monitoring Systems With Color Coding of Measurement Results
    Pleus, Stefan
    Baumstark, Annette
    Schauer, Sebastian
    Koelle, Julia
    Jendrike, Nina
    Mende, Jochen
    Haug, Cornelia
    Freckmann, Guido
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024, 18 (03): : 644 - 652
  • [27] PERFORMANCE EVALUATION OF THE CONTOUR BLOOD GLUCOSE MONITORING SYSTEM, WITH AN UPDATED METER ALGORITHM, IN THE HANDS OF USERS
    Bailey, T.
    Klaff, L. J.
    Wallace, J. F.
    Greene, C.
    Pardo, S.
    Simmons, D. A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 : A27 - A28
  • [28] Accuracy Evaluation of Contour Next Compared with Five Blood Glucose Monitoring Systems Across a Wide Range of Blood Glucose Concentrations Occurring in a Clinical Research Setting
    Klaff, Leslie J.
    Brazg, Ronald
    Hughes, Kristen
    Tideman, Ann M.
    Schachner, Holly C.
    Stenger, Patricia
    Pardo, Scott
    Dunne, Nancy
    Parkes, Joan Lee
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 (01) : 8 - 15
  • [29] ACCURACY OF THE NEW CONTOUR® CARE BLOOD GLUCOSE MONITORING SYSTEM USING NEW CONTOUR CARE TEST STRIPS
    Brown, D.
    Wayland-Smith, A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A122 - A122
  • [30] Performance evaluation of FreeStyle for blood glucose monitoring system
    Kuwa, K
    EUROMEDLAB 2003: PROCEEDINGS OF THE 15TH IFCC-FESCC EUROPEAN CONGRESS OF CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, : 587 - 591