Accuracy and user performance evaluation of the Contour® Next Link 2.4 blood glucose monitoring system

被引:10
|
作者
Bailey, Timothy [1 ]
Wallace, Jane F. [2 ]
Greene, Carmine [2 ]
Pardo, Scott [2 ]
Brown, Daniel [2 ]
Pflug, Brian [2 ]
Klaff, Leslie J. [3 ]
机构
[1] AMCR Inst Inc, Escondido, CA 92025 USA
[2] Bayer HealthCare LLC, Diabet Care, Whippany, NJ 07981 USA
[3] Rainier Clin Res Ctr, Renton, WA 98057 USA
关键词
Self-monitoring of blood glucose; Type; 1; diabetes; 2; INSULIN; THERAPY;
D O I
10.1016/j.cca.2015.06.001
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The Contour (R) Next Link 2.4 blood glucose monitoring system (BGMS), which communicates wirelessly exclusively with a Medtronic insulin pump, was assessed in 2 separate studies. Methods: In the laboratory study (N = 100), subject capillary fingertip samples were tested in duplicate using 3 test strip lots; accuracy was assessed based on ISO 15197:2013 section 63 accuracy criteria (95% within +/- 15 mg/dl or +/- 15% of reference for glucose <100 and >= 100 mg/dl, respectively). In the clinical trial (N = 219), untrained subjects with diabetes tested capillary fingertip and palm blood samples and completed an ease-of-use questionnaire. BGMS and YSI glucose analyzer results were compared based on ISO 15197:2013 section 8 accuracy criteria. Results: In the laboratory study, 100% of results met ISO 15197:2013 section 6.3 accuracy criteria. In the clinical trial, 98.6% of capillary fingertip and 972% of palm results from subjects met ISO 15197:2013 section 8 accuracy criteria. By Parkes-Consensus Error Grid analysis, 100% of subject capillary fingertip results were within Zone A. Based on questionnaire results, the majority of subjects found the BGMS easy to use. Conclusions: The BGMS exceeds ISO 15197:2013 section 63 and section 8 accuracy criteria in the laboratory and in the hands of untrained users with diabetes. (C) 2015 The Authors. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:139 / 145
页数:7
相关论文
共 50 条
  • [1] ACCURACY, PRECISION, AND USER PERFORMANCE EVALUATION OF THE CONTOUR® NEXT LINK 2.4 BLOOD GLUCOSE MONITORING SYSTEM
    Bailey, T.
    Klaff, L. J.
    Wallace, J. F.
    Greene, C.
    Pardo, S.
    Brown, D.
    Pflug, B.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A62 - A62
  • [2] USER PERFORMANCE EVALUATION OF THE CONTOUR® PLUS LINK 2.4 BLOOD GLUCOSE MONITORING SYSTEM
    Wallace, J.
    Caswell, M.
    Frank, J.
    Pardo, S.
    Dunne, N.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A81 - A81
  • [3] ACCURACY EVALUATION OF THE CONTOUR® PLUS LINK 2.4 BLOOD GLUCOSE MONITORING SYSTEM
    Brown, D.
    Pflug, B.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A77 - A77
  • [4] ACCURACY, PRECISION, AND USER PERFORMANCE EVALUATION OF THE CONTOUR® NEXT BLOOD GLUCOSE MONITORING SYSTEM WITH THE CONTOUR® NEXT TEST STRIP
    Bernstein, R. M.
    Caswell, M.
    Frank, J.
    Fullam, J.
    Pardo, S.
    Harrison, B.
    Dunne, N.
    Wallace, J. F.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A55 - A55
  • [5] Accuracy of the Contour® Next Link 2.4 blood glucose monitoring system in Japanese individuals: a single-center study
    Katsuki, Takeshi
    Kondo, Yuko
    Fujita, Masataka
    Tanaka, Hajime
    Suzuki, Rina
    Takeda, Hiroko
    Kawai, Toshihide
    DIABETOLOGY INTERNATIONAL, 2023, 14 (01) : 103 - 108
  • [6] Accuracy of the Contour® Next Link 2.4 blood glucose monitoring system in Japanese individuals: a single-center study
    Takeshi Katsuki
    Yuko Kondo
    Masataka Fujita
    Hajime Tanaka
    Rina Suzuki
    Hiroko Takeda
    Toshihide Kawai
    Diabetology International, 2023, 14 : 103 - 108
  • [7] Accuracy of the CONTOUR® Link Blood Glucose Monitoring System
    Harrison, Bern
    Halldorsdottir, Solveig
    DIABETES, 2011, 60 : A240 - A240
  • [8] COMPARATIVE PERFORMANCE EVALUATION OF THE CONTOUR® NEXT BLOOD GLUCOSE MONITORING SYSTEM
    Klaff, L. J.
    Hughes, K.
    Tideman, A. M.
    Schachner, H. C.
    Stenger, P.
    Parkes, J. L.
    Pardo, S.
    Dunne, N.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A66 - A66
  • [9] Accuracy and User Performance Evaluation of a Blood Glucose Monitoring System
    Caswell, Michael
    Frank, Joy
    Viggiani, Maria T.
    Pardo, Scott
    Dunne, Nancy
    Warchal-Windham, Mary Ellen
    Morin, Robert
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 (03) : 152 - 158
  • [10] Accuracy and user performance evaluation of a blood glucose monitoring system which wirelessly transmits results to compatible insulin pumps Evaluation of the CONTOUR PLUS LINK 2.4 blood glucose monitoring system, assessed according to ISO 15197:2013 criteria
    Caswell, Michael
    Brown, Daniel
    Frank, Joy
    Wallace, Jane F.
    Pardo, Scott
    CURRENT MEDICAL RESEARCH AND OPINION, 2020, 36 (05) : 757 - 764