A comparison of the Seeing Optical Stylet and the gum elastic bougie in simulated difficult tracheal intubation: a manikin study

被引:20
|
作者
Evans, A
Morris, S
Petterson, J
Hall, JE
机构
[1] Univ Wales Hosp, Cardiff CF14 4XN, S Glam, Wales
[2] Cardiff Univ, Wales Coll Med, Cardiff, S Glam, Wales
关键词
D O I
10.1111/j.1365-2044.2006.04539.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Management of the difficult airway is one of the major challenges that anaesthetists face. The flexible fibreoptic scope is widely available but its use requires a level of skill, training and continued practice that is not universally found in all anaesthetists, particularly trainees. The Seeing Optical Stylet is a new, semirigid fibreoptic stylet 'scope. We compared the Seeing Optical Stylet with a gum elastic bougie in a simulated Cormack and Lehane Grade 3 laryngoscopy in a manikin. Forty-four anaesthetists were timed while intubating the manikin's trachea with both devices. The mean (SD) time taken with the Seeing Optical Stylet was 20.8 (9.3) s and with the bougie 30 (19.8) s (p = 0.001). Oesophageal intubation occurred six times with the bougie but did not occur with the Seeing Optical Stylet (p = 0.011). We conclude that the Seeing Optical Stylet may be superior to the bougie in difficult tracheal intubation. We feel that the results of this manikin trial are sufficiently encouraging to proceed to a clinical trial in patients.
引用
收藏
页码:478 / 481
页数:4
相关论文
共 50 条
  • [21] Comparison of Trachway® intubating stylet and Macintosh laryngoscope in tracheal intubation: A manikin study
    Shyr, M. -H.
    Ong, J.
    Lee, C. -L.
    Lai, H. -Y.
    Chen, T. -Y.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 268 - 268
  • [22] Utility of gum-elastic bougie for tracheal intubation during chest compressions in a manikin: a randomized crossover trial
    Komasawa, Nobuyasu
    Cho, Takashi
    Mihara, Ryosuke
    Minami, Toshiaki
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (01): : 54 - 56
  • [23] Gum elastic bougie for difficult double-lumen intubation
    Baraka, A
    ANAESTHESIA, 1997, 52 (09) : 929 - 929
  • [24] Gum elastic bougie for difficult double-lumen intubation
    Weller, RM
    ANAESTHESIA, 1998, 53 (03) : 311 - 311
  • [25] A more 'failsafe' approach to difficult intubation with the gum elastic bougie
    Brimacombe, J
    Howath, A
    Keller, C
    ANAESTHESIA, 2002, 57 (03) : 292 - 292
  • [26] Comparison of a Disposable Bougie versus a Newly Designed Malleable Bougie in the Intubation of a Difficult Manikin Airway
    Boedeker, Ben H.
    Bernhagen, Mary
    Miller, David J.
    Murray, W. Bosseau
    MEDICINE MEETS VIRTUAL REALITY 18, 2011, 163 : 65 - 67
  • [27] Comparison between the Trachway video intubating stylet and Macintosh laryngoscope in four simulated difficult tracheal intubations: A manikin study
    Ong, Jimmy
    Lee, Chia-Ling
    Huang, Shen-Jer
    Shyr, Ming-Hwang
    TZU CHI MEDICAL JOURNAL, 2016, 28 (03): : 109 - 112
  • [28] Tracheal intubation through the laryngeal mask using a gum elastic bougie
    Gajraj, NM
    ANAESTHESIA, 1996, 51 (08) : 796 - 796
  • [29] In case of difficult intubation with the Airtraq®: The gum elastic bougie may assist
    Donat, N.
    Villevieille, T.
    Masson, Y.
    Vauthier, A.
    Rousseau, J. -M.
    Pelletier, C.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2011, 30 (01): : 87 - 88
  • [30] Endotracheal Intubation with Laryngeal Mirror in Simulated Difficult Direct Laryngoscopy: Comparison of Gum Elastic Bougie Versus Styleted Endotracheal Tube
    Anju Ghai
    Neha Bharti
    Mamta Jain
    Sarthak Wadhera
    Anish Kumar Singh
    Raman Wadhera
    Indian Journal of Otolaryngology and Head & Neck Surgery, 2022, 74 : 5448 - 5453