Comparison of a Disposable Bougie versus a Newly Designed Malleable Bougie in the Intubation of a Difficult Manikin Airway

被引:0
|
作者
Boedeker, Ben H. [1 ,2 ]
Bernhagen, Mary [1 ]
Miller, David J. [1 ]
Murray, W. Bosseau [3 ]
机构
[1] Univ Nebraska Med Ctr, Dept Anesthesiol, Omaha, NE USA
[2] Omaha VA Med Ctr, Res Serv, Omaha, NE USA
[3] Penn State Coll Med, Clin Simulat Ctr, Hershey, PA USA
来源
关键词
Bougie; intubation; video laryngoscope; GUM ELASTIC BOUGIE; TRACHEAL INTUBATION;
D O I
10.3233/978-1-60750-706-2-65
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The endotracheal bougie is used for difficult intubations when only a minimal glottic view is obtained. Standard bougies are designed for use during direct, line-of-sight viewing of the glottic opening. With videolaryngoscopy, intubators "see around the corner", thus requiring a bougie which can be shaped to follow a significant curve. A malleable bougie with an imbedded internal wire was created to enable intubators to shape the curve to best fit a difficult airway. This pilot study examined the malleable bougie compared to the SunMed (TM) bougie in a simulated difficult airway intubation using video laryngoscopy.
引用
收藏
页码:65 / 67
页数:3
相关论文
共 50 条
  • [1] Comparison of the Airway Scope®, gum elastic bougie and fibreoptic bronchoscope in simulated difficult tracheal intubation:: a manikin study
    Koyama, Y.
    Inagawa, G.
    Miyashita, T.
    Kikuchi, T.
    Miura, N.
    Miki, T.
    Kurihara, R.
    Kamiya, Y.
    Goto, T.
    ANAESTHESIA, 2007, 62 (09) : 936 - 939
  • [2] Comparison of Bougie-Assisted Intubation with Traditional Endotracheal Intubation in a Simulated Difficult Airway
    Messa, Matthew J.
    Kupas, Douglas F.
    Dunham, Douglas L.
    PREHOSPITAL EMERGENCY CARE, 2011, 15 (01) : 30 - 33
  • [3] To shape or not to shape ... Simulated bougie-assisted difficult intubation in a manikin
    Hodzovic, I
    Wilkes, AR
    Latto, IP
    ANAESTHESIA, 2003, 58 (08) : 791 - 797
  • [4] Using a disposable flexible fiberoptic scope as a bougie for difficult intubation
    Rabadi, Daher K.
    Almasarweh, Sami A.
    Abubaker, Ahmad K.
    Shawaqfeh, Nedal
    Alsalman, Salem R.
    Madain, Zaid
    JOURNAL OF EMERGENCIES TRAUMA AND SHOCK, 2024, 17 (01) : 43 - 45
  • [5] Difficult intubation, the bougie and the stylet
    Jones, I
    EMERGENCY MEDICINE JOURNAL, 2002, 19 (05) : 433 - 434
  • [6] Comparison of the stylet and the gum elastic bougie in tracheal intubation in a simulated difficult airway
    Khan, Riaz Ahmed
    Khan, Farah Ashraf
    Azam, Muhammad
    ANAESTHESIA PAIN & INTENSIVE CARE, 2014, 18 (03) : 256 - 259
  • [7] Evaluation of a new bougie design for the difficult airway: a manikin crossover trial
    Brunckhorst, T. L.
    Grimmett, W.
    Mun-San Kwan, M. M.
    ANAESTHESIA AND INTENSIVE CARE, 2018, 46 (05) : 544 - 545
  • [8] A comparison of a fiberoptic stylet and a bougie as adjuncts to direct laryngoscopy in a manikin-simulated difficult airway
    Kovacs, George
    Law, J. Adam
    McCrossin, Chris
    Vu, Mark
    Leblanc, Derek
    Leblanc, Derek
    Gao, Jun
    ANNALS OF EMERGENCY MEDICINE, 2007, 50 (06) : 676 - 685
  • [9] A comparison of the Seeing Optical Stylet and the gum elastic bougie in simulated difficult tracheal intubation: a manikin study
    Evans, A
    Morris, S
    Petterson, J
    Hall, JE
    ANAESTHESIA, 2006, 61 (05) : 478 - 481
  • [10] Comparison of Preloaded Bougie versus Standard Bougie Technique for Endotracheal Intubation in a Cadaveric Model
    Baker, Jay B.
    Maskell, Kevin F.
    Matlock, Aaron G.
    Walsh, Ryan M.
    Skinner, Carl G.
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2015, 16 (04) : 588 - 593