Test Beam Performance of the CALICE Scintillator based Electromagnetic Calorimeter Prototype

被引:0
|
作者
Khan, M. Adil [1 ]
机构
[1] Kyungpook Natl Univ, Dept Phys, Taegu 702701, South Korea
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The design of high performance electromagnetic calorimeter for the future Collider detector required a high granularity sampling calorimeter, a sandwich of absorber and a sensitive material. A new sampling calorimeter prototype using a very thin plastic scintillator as an active material and tungsten as a passive absorber and the multi-pixel photon counter (MPPC) for readout has been made to produce better position resolution. As a part of this R&D study, Small Extruded Plastic Scintillator of size 10 x 45 x 3 mm(3) and a tungsten plate with 3.5 mm thick are sandwiched together to Fabricate a scintillator base electromagnetic calorimeter prototype. The Prototype has a stack of 30 layers, having dimension of 18 x 18 cm. The total number of channels is 2160 for readout consisting of not only longitudinal but also transverse layers. The scintillation light produced in plastic scintillator strips enters a wavelength shifting(WLS) fiber placed inside the plastic scintillator is guided to the sensitive photo detector 1600 pixel MPPC with a sensitive region of 1 x 1 mm(2). The electromagnetic calorimeter test beam performance has been studied with various electron and pion energies during summer 2008 and 2009 at Fermilab. We present test beam setup, analysis procedure and results on test beam of electromagnetic calorimeter performance in particular the temperature corrections and systematic errors.
引用
收藏
页码:1204 / 1210
页数:7
相关论文
共 50 条
  • [21] Engineering prototype of the CALICE analog hadron calorimeter
    Garutti, Erika
    XIV INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR 2010), 2011, 293
  • [22] Test beam performance of the electromagnetic calorimeter of the NOMAD experiment
    Autiero, D
    BaldoCeolin, M
    Bobisut, F
    Cattaneo, PW
    Camilleri, L
    Cavasinni, V
    Collazuol, G
    Conforto, G
    Conta, C
    Contalbrigo, M
    DelPrete, T
    DeSanto, A
    Ferrari, R
    Fraternali, M
    Gibin, D
    Gninenko, SN
    Graziani, G
    Guglielmi, A
    Iacopini, E
    Kovzelev, AV
    LaRotonda, L
    Lacaprara, S
    Lanza, A
    Laveder, M
    Lupi, A
    Martelli, F
    Mezzetto, M
    Orestano, D
    Pastore, F
    Pennacchio, E
    Petti, R
    Polesello, G
    Rimoldi, A
    Salvatore, F
    Sconza, A
    ValdataNappi, M
    Veltri, M
    Vercesi, V
    Volkov, SA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 387 (03): : 352 - 364
  • [23] CMS electromagnetic calorimeter performance and test beam results
    Bruneliere, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (01): : 33 - 35
  • [24] Test beam results on the performance of the CMS electromagnetic calorimeter
    Zabi, Alexandre
    Calorimetry in High Energy Physics, 2006, 867 : 350 - 357
  • [25] Performance of a prototype CMS hadron barrel calorimeter in a test beam
    Bodek, Arie
    IEEE Transactions on Nuclear Science, 1999, 46 (3 I): : 407 - 409
  • [26] Performance of a prototype CMS Hadron Barrel Calorimeter in a test beam
    Bodek, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 407 - 409
  • [27] Performance of a prototype CMS Hadron Barrel Calorimeter in a test beam
    De Barbaro, P
    PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 1998, : 217 - 223
  • [28] Separation of Two Overlapping Electromagnetic or Electromagnetic - Hadronic Showers in CALICE Highly Granular Physical Calorimeter Prototype
    Shpak, Kostiantyn
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [29] Beam test of a prototype CsI calorimeter
    Kessler, RS
    Roodman, A
    Shawhan, P
    Solomey, N
    Winstein, B
    Hansen, S
    Nguyen, H
    Ray, R
    Tschirhart, R
    Whitmore, J
    Nakaya, T
    Lindgren, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 368 (03): : 653 - 665
  • [30] Performance of the prototype of the electromagnetic calorimeter for PANDA
    Kavatsyuk, M.
    Bremer, D.
    Dormenev, V.
    Drexler, P.
    Eissner, T.
    Erni, W.
    Guliyev, E.
    Hennino, T.
    Krusche, B.
    Lewandowski, B.
    Lohner, H.
    Moritz, M.
    Novotny, R. W.
    Peters, K.
    Pouthas, J.
    Rosier, P.
    Steinacher, M.
    Tambave, G.
    Wilms, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 (01): : 77 - 91