Experimental study on two type of indirect evaporative cooling heat recovery ventilator

被引:6
|
作者
Huang, Sheng [1 ]
Li, Wuyan [1 ]
Lu, Jun [1 ]
Li, Yongcai [1 ]
机构
[1] Chongqing Univ, Fac Urban Construct & Environm Engn, Chongqing, Peoples R China
基金
美国国家科学基金会;
关键词
Heat recovery; Indirect evaporative cooling; Experimental analysis; COOLER; PERFORMANCE; SYSTEMS;
D O I
10.1016/j.proeng.2017.09.910
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Heat recovery ventilator is a feasible way to ease the contradiction between indoor air quality and fresh air handling energy consumption. The paper presents an experimental analysis of a heat recovery ventilator which uses only sensible heat exchanger combined with indirect evaporation cooling (IEC) technology. In this study, two different placement methods (horizontal and vertical) prototypes of heat recovery ventilator combine with IEC were made and the structure and related parameters of the two prototypes were introduced specifically. Then, the porotypes were test on the test rig with different summer operating conditions. Additionally, based on the experimental resulting, the energy consumption saving capability in different China's regions of the two prototypes were evaluated by a specific net energy saving parameter, and the result shows that both vertical and horizontal IECs can reduce energy consumption during cooling seasons in most regions of China. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:4105 / 4110
页数:6
相关论文
共 50 条
  • [21] Theoretical and experimental study on heat and mass transfer of a porous ceramic tube type indirect evaporative cooler
    Sun, Tiezhu
    Huang, Xiang
    Qu, Yueying
    Wang, Fenghao
    Chen, Yi
    APPLIED THERMAL ENGINEERING, 2020, 173
  • [22] Design Selection Method of Exhaust Air Heat Recovery Type Indirect Evaporative Cooler
    Guo, Chunmei
    Li, Yu
    Li, Xianli
    Bai, Ruxue
    Dong, Chuanshuai
    SUSTAINABILITY, 2023, 15 (09)
  • [23] Effectiveness of crossflow plate heat exchanger for indirect evaporative cooling
    Stoitchkov, NJ
    Dimitrov, GI
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1998, 21 (06): : 463 - 471
  • [24] Performance experiment for heat pipe indirect evaporative cooling system
    Huang, Xiang
    Wu, Junmei
    Wang, Xiaojie
    Zheng, Jiujun
    Huagong Xuebao/Journal of Chemical Industry and Engineering (China), 2006, 57 (SUPPL.): : 63 - 67
  • [25] Performance of heat recovery system using evaporative cooling
    Dept. of Mechanical Design Engineering, Chungnam Nat'l Univ., Korea, Republic of
    Trans. Korean Soc. Mech. Eng., B, 1 (37-43):
  • [26] A parametric study of the heat exchanger copper coils used in an indirect evaporative cooling system
    Esmaeel Fatahian
    Hesamoddin Salarian
    Hossein Fatahian
    SN Applied Sciences, 2020, 2
  • [27] A parametric study of the heat exchanger copper coils used in an indirect evaporative cooling system
    Fatahian, Esmaeel
    Salarian, Hesamoddin
    Fatahian, Hossein
    SN APPLIED SCIENCES, 2020, 2 (01):
  • [28] Indirect evaporative cooling systems: an experimental analysis in summer condition
    De Antonellis, Stefano
    Joppolo, Cesare Maria
    Leone, Calogero
    Liberati, Paolo
    Milani, Samanta
    BEYOND NZEB BUILDINGS, 2017, 140 : 467 - 474
  • [29] Experimental investigation on performance of fabrics for indirect evaporative cooling applications
    Xu, Peng
    Ma, Xiaoli
    Zhao, Xudong
    Fancey, Kevin S.
    BUILDING AND ENVIRONMENT, 2016, 110 : 104 - 114
  • [30] Experimental analysis of a cross flow indirect evaporative cooling system
    De Antonellis, Stefano
    Joppolo, Cesare Maria
    Liberati, Paolo
    Milani, Samanta
    Molinaroli, Luca
    ENERGY AND BUILDINGS, 2016, 121 : 130 - 138